Tempest Tornado 1900 Manuale utente

Cyclone Enclosure User Manual page 1
User Manual and Installation Guide
Tornado Moving Light Enclosures
Tempest Lighting, Inc.
13110 Saticoy Street, Unit C
N. Hollywood, CA 91605, USA
Tel +1 818 787 8984
Fax +1 818 982 5510
www.tempest.org
For the following products, manufactured after
August 2013
Tornado 1900, 1950
Tornado 2000, 2100
Tornado 2200, 2300
Tornado 2400
With DEC3.3 GoldilocksTM rev 0.01.006 or higher
In the interest of continuous product improvement, the information in this document is subject to change without
notice. Neither Tempest Lighting, Inc. nor its representatives or agents may be held liable for expense or injury
arising from it.
© Tempest Lighting Inc. All Rights Reserved September, 2013
Lamp
Heater Fan RelayOn DMXTemp
ESC OK
User Manual
Tornado Moving Light
Enclosures

Cyclone Enclosure User Manual page 2
Table of Contents
1Introduction.........................................................................................................6
Dimensions ...................................................................................................7
2Installation........................................................................................................ 10
Planning...................................................................................................... 11
Mounting –Tornado 1900-1950............................................................... 11
Mounting –Tornado 2000 and up ............................................................ 12
Orientation Guidelines............................................................................... 14
Drainage ..................................................................................................... 15
Installation above public Spaces ............................................................... 16
3Wiring and Control ........................................................................................... 17
Conduit entry holes ................................................................................... 17
One or Two Power Circuits? ...................................................................... 18
4Digital Enclosure Control DEC3.3TM with GoldilocksTM.......................... 20
DEC3.3 Schematic...................................................................................... 21
DEC3.3 Main Functions.............................................................................. 22
Factory Settings –Basic Mode ................................................................... 22
Operating Modes ....................................................................................... 23
DEC3.3 Control Parameters....................................................................... 24
Start-up Validation ..................................................................................... 25
DMX Connections....................................................................................... 25
Remote Device Management (RDM) .......................................................... 27
Control Interface........................................................................................ 28
RDM Monitoring and Configuration.......................................................... 32
Firmware Upgrade over RDM..................................................................... 33
5Mounting the Luminaire................................................................................... 34
Tornado 1900-1950 .................................................................................. 35
Tornado 2000, 2100, 2200, 2300............................................................ 36
Vari*Lites and the Vari*Lite Hook Bracket ................................................ 38
Martin MAC III and other tall Luminaires .................................................. 39
Shorter Luminaires Requiring Bracket Standoffs...................................... 40

Cyclone Enclosure User Manual page 3
Mounting the Luminaire –Tornado 2400................................................. 41
6Closing up the Enclosure ................................................................................. 42
7Operation.......................................................................................................... 44
8Routine Maintenance........................................................................................ 45
9Troubleshooting............................................................................................... 47
10 Limited Warranty .............................................................................................. 49
11 Tempest Product Support ................................................................................ 50

Cyclone Enclosure User Manual page 4
CERTIFICATE AND DECLARATION OF CONFORMITY FOR CE MARKING
Tempest Lighting, Inc.
13110 Saticoy Street, Unit C, North Hollywood, CA 91605, USA
t: +1 818 787 8984 f: +1 818 982 5770 e: info@tempestlighting.com
www.tempest.org
Tempest Lighting, Inc. declares that their:
Tornado Lighting Enclosure Series 19xx.xxx, 2xxx.xxx
complies with the Essential Requirements of the following EU Directives:
Low Voltage Directive 2006/95/EC Test Report 60065-2000-13
Electromagnetic Compatibility Directive 2004/108/EC Test Report 61000-2000-15
and further conforms with the following EU Harmonized Standards:
EN 60065 : 2002 Test Report 60065-2000-13
EN 60529:2001-2002 Test Report 60529-2000-14
EN 61000-6-3:2007+A1:2011 Test Report 61000-2000-15
EN61000-6-1:2007 Test Report 61000-2000-15
EN55015:2006+A2:2009 Test Report 61000-2000-15
Dated: 1st March 2013
Position of signatory: President
Name of Signatory: Tim Burnham
Signed below:
on behalf of Tempest Lighting, Inc.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Cyclone Enclosure User Manual page 5
This is to certify that the following products
Tornado 2000.US(H,V) Lighting Enclosure
Tornado 2050.US Lighting Enclosure
Tornado 2000.US(H,V) Lighting Enclosure
Tornado 2200.US(H,V) Lighting Enclosure
Tornado 2300.US(H,V) Lighting Enclosure
Tornado 2400.US Lighting Enclosure
Have been tested and approved to standards UL 508 (electrical) and UL 50 (environmental), as
NEMA 3R enclosures, for use in the United States and Canada.
This declaration is made by the manufacturer
Tempest Lighting, Inc.
13110 Saticoy Street, Unit C
North Hollywood, CA 91605, USA
This declaration is based on tests that were conducted on the submitted samples of the above
mentioned products.
Listing Report No. 3198609LAX-001a refers.
Dated: December 12th, 2010
Signature . . . . . . . . . . . . . .
Tempest Lighting Inc
Tempest Lighting, Inc.,
13110 Saticoy Street, North Hollywood, CA 91605, USA
www.tempest.org info@tempestlighting.com
t: +1 818 787 8984
f: +1 818 982 5582

Cyclone Enclosure User Manual page 6
1Introduction
Using This Manual
Please read this manual in its entirety before starting work. All the information contained is
important, and should be read carefully before proceeding. Heed all warnings and advisories.
Terminology:
Enclosure - Tornado Lighting Enclosure
Luminaire - intelligent lighting fixture that will be placed into the enclosure
DMX - ANSI E1.11-2008, Entertainment Technology - USITT DMX512-A, Asynchronous Serial Digital
Data Transmission Standard for Controlling Lighting Equipment and Accessories.
RDM - ANSI E1.20-2006, Entertainment Technology - RDM, Remote Device Management over
DMX512 Networks
Icon Key:
Valuable information
Electrical Warning
Safety Information
IMPORTANT SAFETY NOTICE: All safety instructions provided by the luminaire manufacturer must be
followed carefully. Failure to do this may void both the luminaire and the enclosure warranties.
When working at heights or in awkward locations, it is imperative to develop a safety plan, based on
the information in this manual, and on local conditions and safety regulations. The safety plan must
be approved by the site engineer/safety officer, as appropriate to local conditions. NEVER attempt
to install Tornado enclosures in high winds or when precipitation is present or imminent.

Cyclone Enclosure User Manual page 7
Dimensions
CAD drawings in DWG and PDF format are available for download at www.tempest.org
Tornado 1900 Tornado 1950
Down)
Tornado 2000-2100
Tornado 2000-2100

Cyclone Enclosure User Manual page 8
Tornado 2200-2300
Tornado 2400

Cyclone Enclosure User Manual page 9
Note –Draw Latch Clearance
Allow adequate clearance for all latches.
Note - Marine Latches
Marine Latches require a tool to open the enclosure.
Latch Plate
3”/75mm
Latch Plate
Marine Latch.
Designs vary slightly by
model.
Note: Tornado 2400 may be installed base up or base down only

Cyclone Enclosure User Manual page 10
2Installation
Safety and Warnings
Read the Manual before installing the enclosure
Read the manual before opening or servicing the enclosure
Never leave the enclosure unattended when open.
Ensure all bolts and terminals are tight and clean
Do not touch the heater unless you can be sure that it is cool.
Observe all warning labels in the enclosure itself.
Do not open any electrical boxes until power is off
Do not open the enclosure in wet weather.
Never move the enclosure with the luminaire inside.
Never handle the enclosure by the globe.
Always lift the enclosure from under the base.
Questo manuale è adatto per i seguenti modelli
6
Indice
Altri manuali Tempest Attrezzatura di illuminazione