CBA 3G-450 User Manual
If supplied with 3-phase mains in star connection, a neutral line must
be supplied.
InDeltaconguration,noneutralisrequired.
This equipment is intended for rack mounting, using suitable tray and runners
etc. The individual modules must not be mounted only by the front panels.
Typically, the amplier will be supplied ready assembled in a cabinet. However,
if supplied in separate units for shipping convenience, the assembly procedure
is as below.
Arrangement of modules in cabinet.
This amplier is supplied with a 34 U instrument rack ready for the insertion
of the modules.
The modules should be arranged with the power unit at the bottom, then two
amplier units, then the amplier input/output unit, then two further amplier
units. The amplier units are distinguished only by the length of DC supply
cable, and so should be ordered from bottom to top such that the unit with
the shortest supply cable is at the bottom, and the unit with the longest supply
cable is at the top.
Cable connection
Connect the centre unit supply cable from the power unit to the centre unit.
Connect each of the amplier modules to the power unit using the connectors
and cables supplied. Connect the SMA to SMA RF cables from each of the
outputs on the centre unit, to the connectors on each of the amplier units, and
similarly for the N to N cables The order of connection is arbitrary. Connect the
BNC to BNC cables from the centre unit to each of the amplier units.
Mains input is via a pre-wired IEC 60309 3 phase plug.
Star congured supplied with a 5 pin plug.
Delta congured supplied with a 4 pin plug