Theralux TVS PRO Manuale utente

Page 1 of 15
TVS PRO
VARIABLE 3 SPEED POOL & SPA PUMP
INSTALLATION AND OPERATION MANUAL
Theralux
12 Gatwood Close
Padstow, NSW 2211
Ph: 1300 131 788
www.theralux.com.au

Page 2 of 15
Read these instructions before operating the pool and spa pump.
Please pass these instructions on to the owner of this equipment.
MODEL: TVS Pro 1.25hp and 1.75hp
DANGER - HAZARDOUS SUCTION.
Do not block water entry into filtration system with any part of your body as the suction can trap hair
or body parts, causing severe injury or death. Do not block suction. Turn off pump immediately if
someone becomes trapped.
Careful Reminder
This appliance is not intended for use by persons (including children) or person/s with reduced
physical, sensory or mental incapability’s, or lack of experience and knowledge, unless they have
supervision or instruction concerning use of the appliance by a person responsible for their safety.
Please check your pump basket, skimmer and entire pool system regularly to maximize the life of
your pool equipment & personal safety. Turn pump off first before checking baskets.
Make sure that all pressure gauges installed are in working condition and the operating pressure is
within limits as specified on the product.
Make sure that each suction inlet, and main drain has a cover that is securely attached and in safe
working condition to meet with all current legislation.
Make sure that all skimmer covers (deck lids) are securely attached and in safe working condition.
These should be replaced every 3 to 4 years.
Remove any obstructions or debris from the main drain cover.
Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at regularly.
Remove obstructions and combustibles from around the pump motor.
Make sure all wiring connections are clean and that all wiring and electrical equipment is in good
condition. Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage
is discovered.
Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump,
heater, etc and void warranty.
Check water balance and sanitizer levels at your local pool shop.
WARNING!
CHILDREN SHOULD BE SUPERVISED AT ALL TIMES TO ENSURE THAT DO NOT PLAY WITH THE PUMP
OR ANY POOL ASSOCIATED ELECTRICAL DEVICE
Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers.
Do not block or cover any pool/spa suction.
Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or
loose.
Suction covers and inlets must be installed as per Australian Standards guideline and provided for
every pump to avoid suction entrapment.
CAUTION!
In the interest of safety, we advise that all brands and types of pool pumps must be installed in
accordance with AS3000 wiring rules or equivalent
If the pump and filter are located below pool water level, it is necessary to fit isolating valves in the
pipe between the pump and the skimmer box and in the return pipe from the filter to the pool.
The fittings on this product are constructed of ABS. Some PVC jointing compounds are incompatible
with ABS. Check compound suitability before use.

Page 3 of 15
THERALUX recommends that all installations are fitted with earth leakage or residual current
protection devices.
Ensure that an electrical isolation switch is located with easy access so that the pump can be switched
off in an emergency.

Page 4 of 15
TVS Pro Fully Variable 3 Speed Pool / Spa Pump
Read these instructions before operating the pool and spa
pump.
Please pass these instructions on to the owner of this equipment.
The TVS PRO pool pump uses a patented variable 3 speed permanent magnet
brushless DC motor. If installed (by a professional) and used correctly it will
significantly reduce operating costs, noise and greenhouse emissions.
INSTALLATION & OPERATING INSTRUCTIONS
THERALUX’S POOL AND SPA PUMP
Congratulations on your purchase of a quality product from the THERALUX range of Pool and Spa
Equipment. You will be pleased with the many years of reliable and efficient performance your THERALUX
pool and spa pump will deliver.
THERALUX pool and spa pumps have been designed to circulate swimming pool and spa water in
conditions set out in the Australian Standard for swimming pool water quality (AS 3633)
THERALUX designs its own electric motors specifically for its pumps. The matched motor and “pump
wetend” are designed to provide quiet operation and energy efficiency.
THERALUX’S totally enclosed fan-cooled motor incorporates “thermal cut-out” overload protection
designed to protect the motor from overheating.
Every THERALUX pool and spa pump is thoroughly water tested against flow, pressure, voltage, current
and mechanical performance parameters. THERALUX’S advanced pump technology provides reliable and
efficient performance that lasts.
THERALUX pool and spa pump are designed with high flow and the head pressures are ideally suited for
the modern pool or spa with extensive equipment.
THERALUX pool and spa pumps are designed to operate with most chlorinators, heaters and other pool
equipment producing correct water flow and energy efficiency.
FEATURES & BENEFITS
Energy Efficient fully variable 3 Speed Motor
Computer-designed impeller and diffuser quickly correct loss of water flow, allowing a free flow
of water with whisper quiet and efficient performance.
Easy to remove; see through strainer lid for easy removal of leaves and debris.
Extra large strainer basket allows long intervals between cleaning.
Continuous duty rated motor with an enclosed fan cooled motor.
Built-in thermal overload protects the motor against damage from overheating.
Every unit is pressure and performance tested in factory ensuring quality and reliability.
High performance Silicon Carbide mechanical seal, fitted for long life in salt & fresh water.
Constructed of strong corrosion and U.V. resistant materials for long life.
A.B.S. quick connect couplings makes installation simple.

Page 5 of 15
Dimensions
Installation Instructions
Location
The pump should be located as close to the water as practicable and mounted on a firm base in a well
drained position, high enough to prevent any flooding. It is the installer’s/owners responsibility to locate
the pump so that it can be accessed for service and maintenance. The rear fan shroud should be installed
at a minimum distance of 100 mm away from any walls or obstructions. This is to allow adequate air flow
from the fan to cool the motor. Overheating due to a lack of cooling voids warranty.
Weather Protection
It is recommended that the pump be protected from the weather.
Enclosures should be ventilated to allow a free flow of air for the fan cooled motor.
Power Connection
THERALUX pool and spa pumps are suitable for connection to a nominal 240-volt 50Hz power supply.
The motor is equipped with a flex and 3-pin plug. If a power outlet is not available within 2 meters of the
pump, a 3-pin power point in a safe, dry place may need to be provided by an electrician.
Note:
Pumps must be either
o Supplied by an isolating transformer, or
o Supplied through a residual current device (RCD) with a rated residual operating current
not exceeding 30mA.
Extension cords are unsafe around pools and must be avoided.
If the supply cord of this product is damaged the dealer or manufacturer must replace it, with
genuine THERALUX pool and spa pump spares.
Water temperature is not to exceed 45 degrees
1.25hp @ 670
1.75hp @ 700

Page 6 of 15
Pipe Connection
A barrel union is provided for connecting to the piping from the pool.
The pumps are designed to accept the following PVC Pipes:
Inlet PVC Position 40mm pipe ID or 50mm fitting ID PVC pressure pipe fittings
Outlet PVC Position 40mm pipe ID or 50mm fitting ID PVC pressure pipe fittings
The use of pipe with a smaller ID than those specified above is not recommended and may cause damage
to the pump voiding warranty.
A straight length of pipe measuring no less than 300mm should be installed in front of the inlet of the
pump allowing quieter and smoother operation.
Suction piping should be free from all air leaks and any humps and hollows, which may cause suction
difficulties.
The outlet piping from the pump should be connected to the inlet connection on the swimming pool filter
(at the filter valve).
For pump installations above water level, it generally requires a check valve in the suction line.
Do not use type ‘P’ (green) plumber’s glue on the barrel unions as this may cause damage to the material
used.
Always install pump for maintenance and service accessibility.
USAGE WARNING
The TVS Pro is manufactured with technological advances including PCB’s and microchips. It is
necessary to turn power off completely for 10 seconds prior to turning pump back on again
Some brands of older style chlorinators may release a small amount of power to the TVS
PROeven whilst it seems turned off. It this occurs the TVS PROmay not reset correctly until
power is completely disconnected.
In some cases, chlorinator manufacturers may be able to modify internal components so as to
work in with the V3PRO. If not a suitable chlorinator may be required.
Theralux’s chlorinator completely disconnects power to the pump when the pump is in off mode.

Page 7 of 15
OPERATION
Starting the Pump
To operate efficiently and to prevent damage to the pump there must be a free flow of water to and from
the pump. Before starting ensure that:
All pipe work is correctly sealed.
Barrel unions on the inlet and outlet are hand tightened and the pipework
is installed square to the pump.
The pool/spa water level is at the correct height.
That all appropriate valves are open and there is nothing preventing the
flow of water through the system.
1. First prime the pump by removing the strainer basket lid and filling the strainer
basket area with water. Replace the lid, ensuring that it seals on the large o-ring.
2. Connect to the power supply and switch on.
3. Allow the pump to run, so that any air trapped in the pipe work and pump may be
expelled.
4. If prime is not established within approximately two minutes, as evidenced by a
strong flow of water from the outlet, switch off the pump for 10 secs and repeat the
procedure. Continued evidence of air under the hair and lint pot lid indicates an air
leak in the suction piping work, which should be rectified to avoid pump damage.
5. If water flow through the pump is continuously tedious to obtain at start-up after
cleaning the lint basket, then an examination of the system to establish a reason
and correct the cause. (ie. Check valve, air leaks, faulty seal/s, crack lid.
TVS Pro variable speed control

Page 8 of 15
Factory Setting Speeds / Star Ratings
1.25hp TVS PRO
Low @ 1600 Medium @ 2400 High @ 2850
1.75hp TVS PRO
Low @ 1450 Medium @ 2400 High @ 2850
Adjustable Speed Mode

Page 9 of 15
1.25hp and 1.75hp TVS VARIABLE 3 SPEED OPERATION
The TVS Pro Variable Speed Pumps has 3 speed settings….
1. Eco (Energy Saving)
This should be used for everyday water filtration
The pump should be operated for approximately 8 hours per day depending on the
surrounding climate, bather loads, pool volume and length of pipework.
In some cases when your pool has areas where water is not turning over, increase the
speed setting
This setting is not recommended to be used with a suction cleaner but may work.
2. Med
This should be used for gentle spa jet action and the majority of suction cleaners when
connected to a skimmer box
3. High
This should be used for backwashing, manual vacuuming of the pool, operating gentle or
soft spa jets and/or water features.
PLEASE NOTE
The TVS Pro will always run at “high” speed for 3 minutes upon start up or a filter
cycle. This assists with priming of the pump and pipe work.
After the initial 3 minutes the TVS Pro will revert back to the previous selected speed
it was set at before it was turned off.
Priming function can be disable, however, this is not recommended
CHANGING PRIME ON/OFF, PRIME DURATION AND PRIME SPEED
Turning Prime On / Off
o Press the stop button 3 times simultaneously
o Screen should read “P off”
o Do this again to turn it on, “P on”
o Disabling Prime function is not recommended for standard operation use
Changing Prime Duration
o Hold Off button for 10sec
o Screen with display P 3 -- Depicting 3 Minutes
This can be increase up to 120 minutes
Press set to save 3 times
Changing Prime Speed
o Hold Off button for 10sec
o Screen with display P 3 -- Depicting 3 Minutes
o Change Prime Duration if required (See above)
Press Set -- P 3
Screen will display 2850 (Highest possible speed)
Increase or decrease as desired by using up and down arrows
Press set to save 2 times

Page 10 of 15
WHEN USING WITH THERALUX / POOL+ MANAGER CONTROLLER WITH RS485 COMMUNICATION
Press and hold OFF button for 10secs
Screen will display P 3 -- Press SET
Screen will display 2850 -- Press SET
Screen will display -- Mod Off
o Press Up or DOWN arrows
o Screen will display Mod On - Press SET
Plug cable into pump from controller
When connect screen should display “----” It is now in slave mode
WHEN USING WITH THERALUX ECOMMANDER
Priming function must be disabled prior to connecting communication plug to motor
o Press the stop button 3 times simultaneously
o Screen should read “P off”
o Do this again to turn it on, “P on”
Set speeds prior to connecting communication plug to motor
o Adjust eco and solar heat demand speed, then save prior to connecting comms
cable
Plug comms cable into pump from controller
Indice
Altri manuali Theralux Pompa per piscina
Manuali Pompa per piscina popolari di altre marche

Resol
Resol DeltaSol B Pro Manuale utente

Evolution Aqua
Evolution Aqua UniTech Perfect 5000 Manuale utente

Outside Living Industries
Outside Living Industries Ubbink Heatermax Pool Guida rapida

CPI
CPI Olympic 2P1815 Manuale utente

Flotec
Flotec FP6121-01 Manuale utente

Pentair
Pentair ONGA LEISURETIME LTP400 Manuale utente