Thermona RC03 Manuale utente

Installation Features and Remote Control Use
8
1
0
1
2
2
1
1
5
6
3
9
RC03

INDEX
USE & REMOTE CONTROL
PROGRAMMING
RC03 .................................................. 1
1Remote Central Heating .................... 3
Display Information............................ 3
2Functioning Mode .............................. 4
3TIME/DATE Setting ........................... 5
4Central Heating and/or Domestic Hot
Water enable ..................................... 6
5Automatic, Manual, Off Functions ..... 7
6Timed Functions................................ 9
7Modification Set-Point Room
Temperature.................................... 12
8Domestic Hot Water Temperature... 13
9Central Heating Circuit Temperature14
10 Enabling or Disabling Self-Learning 14
11 Enabling or Disabling....................... 15
Anti-Frost ................................................. 15
12 Enabling or Disabling Room
Temperature Sensor........................ 15
13 Reset with Reloading of Factory
Values 16
14 Central Heating Error Signals and
Block/Release from Remote............ 17
15 Room and Domestic Hot Water
Temperature.................................... 18
16 Room and Domestic Hot Water Set-
point Temperatures..........................19
17 Time Scheduling Profiles
Programming ...................................21
18 Time Scheduling Profiles .................24
19 Central Heating Circuit Information
Menu 25
20 Domestic Hot Water Circuit
Information Menu .............................26
21 Advanced Menu Information ............28
22 Regulation Algorithm Parameters
Menu 28
23 Warnings..........................................31
24 Remote Installation ..........................31

1Remote Central
Heating
11
2
3
4
10
9
6
7
8
1
5
1 Functions Display
2 Room Set-Point Temperature
Increase
3 Room Set-Point Temperature
Decrease
4 Room Temperature Display /
Confirm Settings
5 Change Functions into Automatic or
Manual or Off (Stand-by)
6 Load Set Comfort (sun) or Economy
(moon)
7 Load Timer Function (if it is in manual
mode) or Holiday (if it is in automatic
mode)
8 Enter into Programming Mode
(PROGR) or Information (INFO)
9 Only Domestic Hot Water Enabling –
Domestic Hot Water/Central Heating –
None
10 Domestic Hot Water Set-Point
Temperature Decrease
11 Domestic Hot Water Set-Point
Temperature Increase
Display Information
9
12
0
3
1
5
8
21
6
12
26 25 24 23 22
28
27
13 14 15 16
1
17 18 19 20 21

12 Central Heating in OFF
13 Domestic Hot Water Function Enabled
(SHOWER mode in progress if blinking)
14 Domestic Hot Water Request
15 Central Heating Request
16 Central Heating Function Enabled
(ANTI-FROST in progress if blinking)
17 Data of CENTRAL HEATING
18 Communication REMOTE –
CENTRAL HEATING activated
19 Error or Service Request
20 COMFORT temperature in progress
(SUN)
21 ECONOMY temperature in progress
(MOON)
22 Boiler Flame Status – Central Heating
power modulation
23 OFF TIMED Function or HOLIDAY
MODE active
24 TIMED function active
25 MANUAL/FORCED function active
26 AUTOMATIC/FORCED function active
27 Room Temperature decreasing
28 Room Temperature increasing
2Functioning Mode
The Remote has three main operation
modes:
- Normal Operation (RUN)
- User Programming Mode (PROGR)
- Advanced Information Mode (INFO)
The first mode serves an ordinary use, it
executes pre-set functions and user requests.
By using the second mode, you can set time
and day of the week, then temperature
settings and time programs.
By using the third mode, you can set or
display the regulation parameters or the ones
related to the connected CENTRAL
HEATING.
The transition between Operating Modes
is performed as follows:
- User Programming Mode (PROGR)
0
12
6
3
9
2
1
1
8
1
5

To shift from RUN to PROGR, briefly push
the button, text will scroll for few
seconds
To return from PROGR to RUN, briefly
push the button, text will scroll for
few seconds
1
5
18
2
1
18
0
12
1
5
2
1
6
9
3
6
0
12
9
3
- Advanced Information Mode (INFO)
0
12
6
3
9
2
1
1
8
1
5
To shift from RUN to INFO, push the
button for at least 3 seconds, text
will scroll for few seconds
To return from INFO a RUN, briefly push the
button, text will scroll for few seconds
1
5
18
2
1
18
0
12
1
5
2
1
6
9
3
6
0
12
9
3
3TIME/DATE Setting
Push button to enter into programming
mode.

By using or buttons, it is
possible to change the blinking value
(Hours).
Push or buttons to select next
value (Minutes).
By using or buttons, it is
possible to change the blinking set value
(Minutes).
Push or buttons to select next
value (Day of Week).
By using or buttons, it is possible
to set the blinking desired value (Day of
Week).
Push button to exit and return to run mode.
4Central Heating and/or
Domestic Hot Water enable
It is possible to enable or disable the Only
Domestic Hot Water and/or Central Heating
functions, by pushing eventually
several times.
Only Domestic Hot Water enabled
(SUMMER)
Push .

2
1
18
1
5
0
12
6
3
91
18
5
21
0
6
9
3
21
Central Heating/Domestic Hot Water
enabled (WINTER)
Push .
1
2
8
1
0
21
5
1
9
3
6
Central Heating and/or Domestic Hot
Water Functions disabled (STAND-BY)
Push .
3
9
6
1
0
2
5
12
81
1
Special programs or enabled functions are
indicated by the presence of the following
icons:
- Domestic Hot Water and Central
Heating Functions enabled.
- Blinking Anti-frost Mode active.
- Only Domestic Hot Water enabled.
- Blinking Shower Mode active.
5Automatic, Manual, Off
Functions
There are three main operating programs with
relating sub-programs of the
chronothermostat: Automatic, Manual, Off:
- Automatic, room temperature has a
changing course which depends on the
time scheduling profiles and set points
(regulation thermal profile).
- Manual, room temperature is regulated at a
fixed user programmed set-point.

- Off, the central heating system is in
stand-by (eventually it activates, if the
temperature goes below the Anti-Frost
Mode when enabled).
Timed sub-programs:
- Automatic Forced,atimed temperature
is fixed until the next set point and it
works separately from the regulation
profile in use.
- Timed Manual, the system proceeds in
manual function mode (user-
programmed set-point) for a
programmable period of time and then
the temperature controller shifts to
Automatic Function mode.
- Timed Off or Holiday Mode, the system
keeps OFF mode for a programmable
period of time and then the temperature
controller shifts to Automatic Function
mode. The function in progress is
shown by the presence of the following
blinking icons (Timed functions) or
(Holiday).
Temperature Controller in Automatic
Mode
Push .
0
1
12
5
81
2
1
6
3
9
9
6
3
1
2
81
12
5
1
0
9
6
3
1
2
81
5
1
0
12
Temperature Controller in Manual Mode
Push .
21
5
1
1
2
8
16
9
3
0
1
5
1
8
2
1
0
21
3
6
9
Temperature Controller in Off Mode
Push .

1
0
5
12
18
2
1
3
6
9 9
6
3
1
2
81
12
5
1
0
Special programs or enabled functions are
indicated by the presence of the following
icons:
- Automatic Function
- + Automatic Forced Function
- Manual Function
- + Timed Manual Function
- Off
- + Timed Off
- + + Holiday Function
6Timed Functions
From Automatic to Timed Off
By pushing button, it is possible to
activate TIMED OFF or HOLIDAY
PROGRAM from the AUTOMATIC
function. In this case, the starting of that
function will be shown below through the
scrolling line and time in minutes for
the function OFF, which can be pre-set
through the and buttons. After
this sequence the Remote Control will
proceed to activate the AUTOMATIC
program.
During the whole process, the remaining time
at the timed function ending will be shown on
the LCD. This period can vary between 10 –
90 minutes (MM: nn), it can be increased or
decreased of 10 minute steps, or it can be in
hours from 2 to 47 (HH: nn), with 1 hour
steps, or in days from 2 to 45 (GG: nn), with 1
day steps. In this case the timed function is
the HOLIDAY PROGRAM.
3
9
9
3
1
5
12
0
5
1
0
21
1
8
18
2
1
1
2
12
6
3
9
0
1
5
1
8
2
1

From AUTOMATIC, push button to
activate TIMED OFF function.
2
5
12
18
1
3
6
9
1
0
Using and buttons, set time
period of TIMED OFF function.
9
3
6
5
1
21
0
8
1
1
2
It is possible to stop timed functions by
pushing when desired.
From Manual to Timed Manual
From the MANUAL function you can
access the TIMED MANUAL function by
pushing button.
It is also possible to stop the timed
functions linked to the setting of the room
temperature by selecting to choose
the desired function.
During timed functions it is possible to
change the temporary setting through
, and buttons, after
pushing .
3
6
9
1
5
12
0
81
2
19
3
6
9
6
3
5
1
21
0
0
81
1
2
5
12
81
1
12
From MANUAL, push to activate the
TIMED MANUAL function.
0
3
6
9
1
5
2
1
1
8
21
During Timed Functions to change room
set-point temperature for timed period,
push .
Indice