Thermoray ISENTECH ITC200E Manuale utente

Thermal Imaging
Camera System
Instruction Manual
Make sure to read and use the ‘Safety Precautions’ before using the product.
Product warranty is included in the instruction manual.
ITC200E
Smart Sensing Solution Provider

1
§Do not use for any purpose other than temperature measurements.
§Do not disassemble arbitrarily. This may cause electric shock or fire. Product
warranty and repair may be penalized.
§Do not touch parts that have been compromised by product damage. It may
cause electric shock or fire. After removing the power supply, find the
designated service center.
§Be careful not to expose the product to excessive heat from direct sunlight or
fire, as there is a risk of fire.
§Be careful not to let liquid (water, alcohol, etc.) get into the product as it is not
waterproof.
§Do not use anything other than the accessories supplied with the camera.
Using other products may cause electric shock or fire.
§When the power supply is disconnected from the outlet, do not remove the
power cord wire. The electric wire may be damaged, resulting in electric shock
or fire.
§Do not move the camera or tablet PC while it is attached to a tripod, as it may
drop or cause injury.
§When a product is defective, it must be repaired through the designated
service center. Devices not approved by the manufacturer cannot be modified
or approved
§If this product or the surrounding of the measuring object fluctuates suddenly,
the accuracy of the measuring degree may be affected. Be sure to store it in
the room at least 30 minutes before use.
§This product is not a medical device for diagnosing diseases, but a device that
measures the degree of measurement and monitors heat. Degree
measurement using this product can never be used as a substitute for medical
treatment or consultation. If there is any problem with the measurement
results, be sure to consult with a specialist.
vCautions of safety
CAUTIONS IN USE

2
This product is affected by the environment in which it is used as an
electronic device (camera), it can be significantly affected by
temperature and humidity.
§It maintains a normal temperature (20°C and 25°C) and has ideal
accuracy when installed in a room with a relative humidity of 50% or less.
§If it is exposed to direct sunlight or installed near a heat source, it may
cause a decrease in accuracy due to an increase in the surrounding
temperature.
§When installing and using this product outdoors, use it under a place
where a tent or structure is installed to minimize the influence of the
external environment.
§When moving from the cold outdoor to warm indoor, water droplets
may form on the product. Be sure to store it at room temperature for
at least 30 minutes before use.
vEquipment Installation Location
§Avoid places exposed to direct sunlight and store in a place free of
liquids or contaminants.
§Store in a safe place from vibration and collision.
§Do not store in hot and humid places when not in use for a long time.
§If you do not comply with the precautions and instructions listed in
the user manual, the sales and manufacturer shall not be held liable
for any quality abnormality.
§Dispose of unusable product components according to local
regulations.
vHow to store and manage equipment

3
vProduct Components
AThermal Imaging Camera USB CableC
Tripod
BUser Manual
D
A B
D
CE
Install'SW
EThermoray Install SW

4
vComponent Name –Thermal Imaging Camera
Lens
Micro 5pin port
Thermal Imaging Camera tightening portCA
BCamera pin portD
A
B
C
D

5
vComponent Name -Tripod
Camera fixing pin Camera fixing screw
Camera direction adjusterC
AB
Camera direction fixing screw
Height adjuster
D
E
B
A
C
D
E

6
How to use a product
vInstalling the Equipment
For companies such as PC rooms, cafes, and restaurants that have limited
space for tripods, equipment use may be restricted. We offer S/W for
Windows so you can use your PC with minimal space on the tripod.
S/W for Windows OS can be downloaded via the archive at THERMORAY
homepage(www.thermoray.co.kr).
The installation method of the product is based on the use of the tripod
of the existing [MT-01]model, and the installation method is as follows.
§Extend the legs of the folded tripod in the right direction.
§Use the tripod’s height adjustment device to adjust the height of the
tripod to suit your environment.
§Place the fixing screws of the tripod on the thermal imaging camera
fixing port.
§Rotate the thermal imaging camera clockwise to secure the screw.
§Rotate the camera fixing screws on the tripod to tighten the thermal
imaging camera and the tripod.
§Loosen the camera orientation fixing screw on the tripod by turning
in counterclockwise.
§Adjust the orientation of the thermal imaging camera by operating
the camer adjuster.
§Rotate the camera orientation fixing screw on the tripod clockwise to
secure the thermal imaging camera.
§Connect the thermal imaging camera to your PC using a USB cable
that can send and receive data.
※ The USB cable is Micro 5 pin to USB A.
If you need atripod that is higher than the standard tripod, you can
purchase it separately at THERMORAY homepage (www.thermoray.co)

7
vGetting Started
You must install the program to use this product on your PC. Procedure
for installing and starting the program is as follows.
§Go to the THERMORAY homepage (www.thermoray.co) and download
the program installation files and driver installation files for your
operating system.Run the program installation file to install
THERMORAY S/W.
§When the file installation is complete, install the thermal imaging
camera driver
①Right click on the camer driver file (seekusb.inf)
②Click install to install the camera driver.
§Reboot the computer when the dedicated S/W and camera drivers are
installed.
※ If you do not reboot, the camera driver may not work properly.
§Connect the thermal imaging camera and PC using a USB cable.
※ Make sure to use a USB cable that can transmit and receive data.
§Execute S/W (THERMORAY.exe).
§When the thermal imaging camera screen appears, wait 5 to 10
minutes for equipment optimization.
vTo exit
§Double-click “THERMORAY” brand image on the upper left of the
main surface of the program.
§Click “Yes (Y)” when the exit window appears.

8
Set up a program
vTo set up
The program setting button is located on the upper right of the main
screen, and the method for setting the program according to the usage
environment is as follows.
§Place the metric reference article at 1.0m or 1.5m from the instrument.
§Click the program setting button and set the frequency on the setting
side.
※ If you do not press the [Apply] button, changes will not be applie
to the program.
§Check the degree of the measurement reference through the screen.
§Measure the degree of the measurement reference using a non-
contact thermometer.
§Repeat the above three sections 3 times to 5 times.
§Check the deviation value of the degree measured by the thermal
camera compared to the degree measured by the non-contact
thermometer.
§Click the program setting button and set the degree deviation value
as input in the degree correction section on the setting menu.
※ If you do not press the [Apply] button, changes will not be applied
to the program.

9
vWindows OS-only programs
Program Configuration
The program structures for Windows-based desktop PCs and laptop PCs
are as follows.
Main Screen
Setting Screen
Indice