Tiger TM-01 Manuale utente

OPERATION
MANUAL
Model: TM-01
Version: 1.01

Safety
information 4
Installation 4
Preparatory before usage 5
Storage 5
Unfolding the package 5
Package
list 5
Installation of the balance 6
Usage conditions 6
Install the balance with wind shield 7
Install the balance with round weighing pan 7
Install the balance with rectangular weighing pan 7
Connect
the power adapter 7
Install the external facilities 7
Warm-up time 7
Adjust the level gauge purpose 8
Display and keys description 8
Power on / Power off the balance 10
Tare function 10
Counting mode 10
Percentage mode 11
Weighing
units 12
Calibration 12
User setups 12
Parameters 13
Communication with a computer 16
RS-232 interface hardware 17
Pin description 17
Routine maintenance and troubleshooting 18
Troubleshooting 18
2

3
Clearance 18
Clearing the stainless steel surface 19
Safety
check 19
Troubleshooting 19
Technical conditions 21
Guarantee 22

4
SAFETY
INFORMATION
To avoid unnecessary damage to the balance, please pay attention to the
following
tips:
•
Please do not use this balance in dangerous area.
•
Please turn off the power of the balance before connecting it or
disconnecting it with other
f
acilities.
•
If the environment
requires
a higher safety standard, please follow the
relevant installation ins
tructions.
•
Excessive electromagnetic interference will make the displayed value
in this balance change.
Once
the interference is dismissed, the balance
could operate in normal way.
•
Please avoid any liquid on the surface of the balance. A piece of
lightl
y
damp cloth is allowed to wipe the balance.
INSTALLATION
•
Please
make sure the local voltage is in line with the rated voltage on the
name board
.
•
Please
pay
special attention when use RS-232 as the pins location
might
be
incompatible with our facilities.
Pl
ease
check
the pins locations before
the connection and turn off the connection of different
c
onfigur
ation.
•
If the facility or the power cord has apparent damage, please turn off the
power, put it or them in a safe place and do not use it or them before they
are fixed.

5
•
This balance could only be connected to our accessories or
optional fittings.
We
are not responsible for
any
modification the
operator mak
es
to our balance, including using the facilities and
cable which are not supplied by us. However, we are always ready to
offer the operation norms
inf
ormation.
•
If the balance does not work well, please contact your local distributor
or
our customer service
c
enter.
PREPARATORY BEFORE
USAGE
STORAGE
This balance
requires
an environment which is free from excessive high
or low temperature, corrosive, vibration, air current and collision.
UNFOLDING THE
PACKAGE
•
Unfold the package and check if there is any outer damage of the balance.
•
If there is outer damage, please
refer
to section
routine
maint
enanc
e
and troubleshooting.
•
Please keep all the package for possible transportation in the future
.
When pack the balance, please remove all the cables to avoid
unnecessary damage.
PACKAGE
LIST

6
INSTALLATION OF THE
BALANCE
Put it in a proper place, please avoid the following situations:
•
Much heat and direct
sunlight.
•
Air currents and
vibr
ations.
•
E
xcessive moisture
.
Usage Conditions
Please do not lay the balance in a
quite damp place for a long time. If the
balance is transferred from a lower
temperature environment to a
higher
temperature environment, please lay it there with power off for around 2
hour
s.
Note: Do not put non-rechargeable battery in the balance when it
is connected with power adaptor.
Model
TM-01
TM-01
TM-01
TM-01
TM-01
Capacity
300g
600g
2kg
3kg
6kg
Readability
0.01g
0.01g
0.01g
0.1g
0.1g
Balance
√
√
√
√
√
Power adaptor
√
√
√
√
√
Pan size (mm)
Φ120
Φ120
180*170
180*170
180*170
Weighing pan
√
√
√
√
√
Weighing pan
support
√
√
√
√
√
Windshield
√
√
User manual
√
√
√
√
√
Rechargeable
battery
√
√
√
√
√
Screws
√
√
√

Install the
balance
with
wind
shield
7
•
Assemble the parts in the indicated
order.
4
3
2
1
Install the
balance
with
round weighing
pan
•
Installation Sequence.
•
Pan support.
Install the balance with rectangular weighing pan
•
Use a Philips screwdriver to orient the 4-M3 screws
in the diagrammatic directions to fix the rectangular
weighing pan on the center of the sensor. Pay
attention to the installation directions.
•
Install the weighing pan.
Connect
the
Power
Adapter
•
Connect
the power adapter to the balance.
•
Connect
the power adapter to the power socket.
21
Install the External Facilities
Turn off the balance before connecting it or disconnecting with external
f
acilities
such as the printer or the
c
omputer.
Warm-up Time
To assure the measure accuracy, the balance must be warmed up for 30
minutes before normal operation.

Adjusting the Level Gauge Purpose
8
•
Adjust the level gauge of the balance.
The lev
el
gauge needs to be adjusted once
its
place is changed.The two front bottom
bolts
L
R
are used to adjust the level gauge.
R
L
•
Spin the two bolts as shown in the figure
until
the bubble in the lev
el
gauge is in the center of
R
the circle. L
•
Normally, it needs to be adjusted repe
at
edl
y
.
DI
SP
LAY
AND
KEYS
DESCRIPTION
1. Count sign.
2.
Weighing
units.
3. Stability sign.
4. Level gauge.

OK
-
Rea
din
g
shown is stabl
e.
9
g
-
Reading
shown is given in
gr
ams.
OZ
-
Reading
shown is given in ounces
(1g
=
0.03527396200
oz).
ct
-
Reading
shown is given in carats
(1g
=
5.0000000000
ct).
dwt
-
Rea
ding shown is given in pennyweight
(1g
= 0.64301493100dwt)
%
-
Rea
ding shown is given in percent weight.
PCS
-
Re
ading shown is given in as a
c
ounting.
-------
The
balance is developing a stable readin
g.
UNABLE
-
Error operation.
HHHHH
H
-
The
weight on the pan
ex
ceeds the capacity of the balance.
LLLLLL
–The pan is not properly seated or has been removed
.
Calibration / Adjustment
Print / Output key
Percentage key
Count / Function confirmation key
Unit conversion key
Tare key
TARE
UNIT
COUNT
%
PRINT
CAL

10
TARE
TARE
COUNT
COUNT
POWER ON/POWER OFF THE BALANCE
Procedure
1. Press the key to power on the balance.
2. Press and hold the key for 5
seconds
to power
off
.
TARE
FUNCTION
Procedure
1. Put a container on the weighing pan.
2. Press the key, the balance will auto tare.
3. Put the object you want to weigh into the container, the balance
will
display the weight of the object.
COUNTING
MODE
Procedure
1. Place the reference object on the weighing pan. To choose the
reference object’s quantity, press the key to display
“10”, then press the key, the reference quantity
will
change
to “20,
50, 100, 1000
pieces
”.
2. Press the key to confirm the selected reference quantity
.
3. Take off the reference object and put the empty container (if
necessary) on the weighing pan and press
to
subtract
its weight.
TARE
UNIT
TARE
Indice