87
Operation
(Without Remote - TG115)
Arming
Slide switch to ARM and 3 short bleeps will
be heard in confirmation. 60 seconds later
(allowing for PIR stabilisation and user exit)
a single bleep will be heard indicating the
system is ready for detection.
Entry Delay and Alarm Timing
There is a 20 second delay after detection
before the unit sounds the alarm (allowing
users to disarm the unit by switching to OFF
when returning). The alarm sounds for 2
bursts of 30 seconds separated by 30 seconds
of silence. The light flashes continually
during this period and carries on until the
unit is switched to OFF.
TG115/115R_Insts.qxd 2/5/06 4:45 pm Page 8