172-65043MA-02 (GP10L/GT10L PowerTrap) 9 Mar 2004
9
Closed System Piping
[Ci]
[Vo]
Condensate
Return
Line
Motive
Medium
Supply
Pressure
[Pm]
Pump Exhaust
[Co]
Steam
Using
Equipment
Condensate
Reservoir [Dh]
[Ve]
[Vi]
Back
Pressure
[Pb]
Temperature
Controller
Air and Non-condensible Gas Discharge
Filling Head [ A]
Sm
Sv
Se
Si So
Sr
Maximum
Equipment
Pressure
[P1]
Steam
for
Heating
Condensate
Supply
[Q]
Pipe the discharge to a safe area such as a pit.
[Ki]
[Rm]
[St]
TLV GT
Backflow Water Hammer
Prevention Check Valve
[Av]
[Vb]
Condensate Outlet Distance from Floor [B]
Primary
Pressure for
Motive
Medium
[Km]
[Vm]
NOTE: In closed system applications, the motive medium must be compatible with the liquid being
pumped. If a non-condensable gas such as air or nitrogen is used as the motive medium, please
consult TLV for assistance.
Q Condensate Supply Se Exhaust Pipe Rm Motive Medium Reducing Valve
A Filling Head Sv Vent Pipe St Steam Trap on Drip Leg
Dh Condensate Reservoir Vi Valve on Condensate Inlet PipePm Motive Medium Supply
Pressure GT PowerTrap Vo Valve on Condensate Outlet Pipe
Pb Back Pressure Ci Condensate Inlet Check Valve Vm Valve on Motive Medium Supply
Si Condensate Inlet Pipe Co Condensate Outlet Check Pipe
So Condensate Outlet Pipe Valve Ve Valve on Exhaust Pipe
Sr Condensate Recovery Line Ki Condensate Inlet Strainer Va Air Vent or Valve
Sm Motive Medium Supply Pipe Km Motive Medium Strainer Vb Bypass Valve
Installation Procedure
Refer to the systems outlined in the “General Description” section on page 5 to select
the correct system and PowerTrap model (GT or GP) for the application. Installation,
inspection, maintenance, repairs, disassembly and adjustment should be done only by
trained maintenance personnel.
(1) Pumped Medium:
!"Fluids that can be discharged through the PowerTrap are limited to steam
condensate, water and non-flammable, non-toxic fluids with specific gravities
0.85 – 1.0. PowerTraps that have been specially constructed for other specific
fluids are not limited by this restriction.
Pipe the discharge to a safe area such as a pit When the rise in piping is 30 m (100 ft) or farther from the
PowerTrap, installation of a check valve is recommended
for the prevention of return water hammer.
NOTE: This sketch is for explanation purposes only
and is not intended as an installation design.
Back
Pressure
[Pb]
Air and Non-condensable Gas Dischar
e
[Va]
TLV
GP/GT