INSTRUCTIONS FOR INSTALLATION AND USE
Important Safety Information - Please Read Carefully
- Always isolate from the mains electricity before installing or carrying out any
maintenance to the EAS -Dose dosing system.
- Power to the EAS -Dose Dosing system must be supplied through a Residual Current
Device (RCD) with a rated residual operating current not exceeding 30mA.
- Pump rating: 220-240V, 50Hz unless marked otherwise.
- Do not operate any appliance if it has a damaged cord or plug, if it is malfunctioning, or if it
has been dropped or damaged in any way.
- This unit is designed to be used indoors and is not suitable for any outdoor applications.
- Ensure the EAS -Dose Dosing System is safely positioned before operating.
Caution: The EAS -Dose Dosing System is not waterproof and therefore must not be
mounted above the aquarium or in any position where it may accidentally fall into water or be
splashed by water.
- Always leave a drip-loop in the cables to prevent water running down the cable and
reaching the power source (see below).
- Dispose of this unit responsibly. Check with your local authority for disposal
information.
Drip Loop
s

2
PARTS REQUIRED FOR INSTALLATION AND OPERATION (NOT
SUPPLIED)
• Residual current device (RCD) with a rated residual operating current not exceeding 30mA.
• Additional silicone hosing and hosing connectors (depending on individual installation
requirements).
• Scissors for cutting the silicone hosing to the required length.
TECHNICAL SPECIFICATION
Power Consumption: 4W
Max Flow: 60ml/minute
Motor Speed: 3800rpm
Accuracy: +/-5%
PARTS LIST
1. LCD display
2. Dosing pump head
3. Silicone hosing (3m)
4. nlet (right)
5. Outlet (left)
6. Non return valve
7. Hosing connector
8. Power supply unit (PSU)
9. Slave connection cable (supplied with Slave only)
10. PSU port -12v (not supplied with Slave)
11. Extension port A for Slave unit
12. Extension port B for Slave unit
13. PC connection ‘ N’
14. PC connection ‘OUT’
15. nput from master (using connection cable
supplied with Slave)

3
12
10
4
5
5
55
5555
5
5
3
67
7
7
8
8
8
9
7
6
6
6
3
3
4
4
4
4
4
4
44
4
2
22
2
222
1
1
1111
1112 14
13
10
11
12
13 14
10
11
12
13 14
15

4
INSTALLATION OF ALL ASTER/SLAVE ODELS
nstalling the EAS -Dose Dosing System is very easy and requires minimal set up, apart from
connecting power cables and silicone hosing.
1. Place the EAS -Dose unit in a convenient, stable position (do not mount it above the
aquarium or in any position where it may accidentally fall into water or be splashed by water)
where it can be easily accessed for maintenance.
Useful Tip: We recommend using the EAS -Dose shelf to allow easy and convenient
installation (shelf sold separately - please see back page for available accessories and spares).
2. Plug the power supply (PSU) into the PSU port (10) on the back of the unit ensuring there
is a drip loop in the power cable (see diagram above).
3. Carefully measure and cut the silicone hosing (3) to the required lengths. Please ensure
that the lengths of hosing are long enough to connect your liquid storage containers to the
inlet(s) (4) on the dosing pump head(s) (1) and to connect the outlet(s) (5) to your
desired dosing location, without any kinks or sagging. Additional silicone hosing and hosing
connectors may be required, depending on individual installation requirements.
4. Each dosing pump head (2) is controlled separately and, depending on model, is numbered
from 1 - 4 from left to right. The inlet (4) is on the right of the dosing pump head (2), and
this is where your chosen liquid is drawn in. The outlet (5) is on the
left and this is where the liquid is dispensed from.
5. nsert the non return valve (6) with the domed section pointing
upwards into the inlet (4) of the dosing pump head (2) (see photo).
6. Connect one end of your cut silicone hosing to your liquid storage
container and connect the other end to the non return valve (6)
ensuring there are no kinks or sagging.
Useful Tip: We recommend you use an EAS -Dose dosing container
(sold separately - please see back page for details).

5
7. nsert a hosing connector (7) (with black dust protector removed) into the outlet (5) on
the left side of the dosing pump head (2) and connect another length of silicone hosing to
the other end. Place the end of this length of hosing in your desired dosing location e.g.
your sump, ensuring there are no kinks or sagging. Secure as required.
Useful Tip: We recommend the use of the EAS -Dose hosing clamp (sold separately - please
see back page for details) to ensure a neat and secure set up.
8. Ensure all connections are tightly secured and that the EAS -Dose unit is installed correctly
before operating. Failure to do so could result in leaks or operating problems.
9. Repeat the above steps for each dosing pump head you wish to use.
EXPANDING YOUR EASI-DOSE DOSING SYSTE
The EAS -Dose Dosing System is expandable and allows two EAS -Dose Slave units (4 pumps
each) to be connected and independently controlled from the Master system (EAS -DOSE 1, 2
or 3) giving you up to 8 additional pumps.
f you wish to expand your EAS -Dose Master system, simply connect an EAS -Dose Slave
(sold separately) to your Master system by inserting one end of the the slave connection cable
(9 - supplied with Slave unit only) into the NPUT socket on the Slave and the other end into
either extension port A or B (11 or 12) on the back of the EAS -Dose Master system. Once
connected the Master system will power and automatically recognise the Slave unit and you
will be able to programme from the Master.
Complete the installation points above for each pump that you wish to use.

6
PROGRA ING YOUR EASI-DOSE ASTER (ALL ODELS)
The EAS -Dose Master units are quickly and easily programmed by using a series of buttons.
A. Pump/OK Button
Use this button to select the pump number you wish
to change settings for. t will allow you to scroll
through each of the pumps’ settings and see the
progress of each dose. At any stage whilst
programming your unit, pressing this button will save
your programmed settings and will return the doser
to running mode (the ‘:’ on the clock will flash whilst
in running mode but not whilst in setting mode).
B. Dose/t Button
This button will allow you change the dose quantity (in ml) and also scroll to the ‘When to
dose’ section. t will also let you scroll left when changing other settings.
C.Time/u Button
This will let you set the time of your unit, and also allow you to scroll right whilst changing
other settings.
D. Manual Feed/+ Button
This button will let you prime your pumps and also manually dose additives.
Please Note: this will not affect your settings when doing so.
When changing settings, it will allow you to increase the number displayed.
ABCD

7
SETTING THE CURRENT TI E
1. Press button C (Time/u) to enter current time. The clock will flash whilst in the settings
mode.
2. Press button C (Time/u) again to scroll through the hours and minutes (selected item will
flash) and using button D (Manual Feed/+) increase the hours/minutes to the correct time.
3. Press button A (Pump/OK) to confirm and save the current time.
SETTING DOSING VOLU E
1. Press button A (Pump/OK) a number of times to scroll through all pump numbers until you
find the pump you wish to set dosing details for.
2. Press button B (Dose/t) to enter the dosing volume setting.
3. Press button D (Manual Feed/+) to adjust the first two digits (from 1 - 19) of the dosing
volume and then press button C (Time/u) to move onto the third digit of the dosing
volume and adjust using button D (Manual Feed/+) (1 - 9). For example, if you wanted to set
the dosing volume to 149ml, you would set the first two digits to 14 and the third digit to 9.
Please Note: Dosing volume can be set from 1ml to 199ml per dose.
SETTING DOSING TI ES
After setting your dosing volume you can set when to dose. Each pump can deliver your
determined dosing volume up to 24 times per day, on each hour, should you require it. Each
pump will start approximately 3 minutes after the previous one in order to allow time for
your chosen additives to mix with your aquarium water. For example if you set two pumps to
dose at 10am, the first will dose at 10am and the second will dose at approximately 10.03am.
1. After setting your dosing volume press button C (Time/u) to scroll through to the ‘when
to dose’ section of the screen. 1 to 24 represents each hour of the day in 24hr time
format. Press button C (Time/u) to scroll right, or button B (Dose/t) to scroll left. An
hour time slot will flash then you are able to select/deselect it.
2. Use button D (Manual Feed/+) to select/deselect the hours when you would like the
pumps to dose. The selected hours will be underlined when the button is pressed and will
be deselected by pressing button D (Manual Feed/+) again. No line will show under the
number when it is deselected.
3. Repeat the above process for all dosing pumps and then press and hold down button A
(Pump/OK) for 2 seconds to confirm and save the settings for all pumps. The dosing unit
will now be in running mode and the ‘:’ on the clock will now be flashing.
Questo manuale è adatto per i seguenti modelli
4
Indice
Lingue:
Altri manuali TMC Pompa dell'acqua
Manuali Pompa dell'acqua popolari di altre marche

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guida alla risoluzione dei problemi

DUROMAX
DUROMAX XP WX Series Manuale utente

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manuale utente

Franklin Electric
Franklin Electric IPS Manuale utente

Xylem
Xylem e-1532 Series Manuale utente

Milton Roy
Milton Roy PRIMEROYAL Manuale utente