★Please read and follow all warnings, precautions and instructions before
installation and use.
★Never connect the solar panel to the control board directly to charge the battery.
★Periodic checks of the opener are required to ensure safe operation.
★Save this manual.

Table of Contents
Safety Installation Information..........................................................................................................................1
Dual Gate Opener Parts List ............................................................................................................................ 2
Single Gate Opener Parts List ......................................................................................................................... 2
Optional Accessories Parts List........................................................................................................................3
Tools Needed: .................................................................................................................................................. 3
Technical Specifications & Features ................................................................................................................4
Dual Gate Overview .........................................................................................................................................6
Single Gate Overview.......................................................................................................................................7
Preparation for Installation ...............................................................................................................................7
Install the Gate Opener on the Gate................................................................................................................8
Mounting of the Control Box........................................................................................................................... 13
Connection of the Power Supply.................................................................................................................... 13
Connection of the Control Board.................................................................................................................... 14
Motor connection for PULL-TO-OPEN ...............................................................................................................15
Motor connection for PUSH-TO-OPEN ..............................................................................................................15
How to learn or erase the Remote ................................................................................................................. 16
Setting of the Control Board........................................................................................................................... 17
Indicate Illustration on the Digital Display When Gate Opener is Running ...................................................19
Adjusting the Limit Switch ..............................................................................................................................20
How to Operate ..............................................................................................................................................20
Maintenance................................................................................................................................................... 20
Trouble Shooting ............................................................................................................................................21
Quick-Setting Guide .......................................................................................................................................22

1
Safety Installation Information
1. READ and FOLLOW all instruction.
2. The gate opener is intended for use with Class I
vehicular swing gates.
Class I denotes a vehicular gate opener (or system)
dwellings, or a garage or parking area associated
therewith.
Install the gate opener only when the opener is
appropriate for the construction and the usage class of
the gate.
3. Gate opening system designers, installers and
users must take into account the possible hazards
associated with each individual application. Improperly
designed, installed or maintained systems can create
risks for the user as well as the bystander. Gate system
design and installation must reduce public exposure to
potential hazards. All exposed pinch points must be
eliminated or guarded.
4. A gate opener can create high levels of force
during normal operation. Therefore, safety features
must be incorporated into every installation. Specific
safety features include safety sensors.
5. The gate must be properly installed and work freely
in both directions prior to the installation of the gate
opener.
6. The gate must be installed in a location so that
enough clearance is provided between the gate and
adjacent structure when opening and closing to reduce
the risk of entrapment. Swinging gates shall not open
into public access areas.
7. The opener is intended for use only on gates used
for vehicles. Pedestrians must be supplied with a
separate access opening. The pedestrian access
opening shall be designed to promote pedestrian usage.
The pedestrian access shall be located such that
persons will not come in contact with the moving
vehicular gate.
8. Pedestrians should never cross the pathway of a
moving gate. The gate opener is not acceptable for use
on any pedestrian gate. Pedestrians must be supplied
with a separate pedestrian access.
9. For an installation utilizing non-contact sensors
(safety sensors), see product manual on the placement
of non-contact sensors (safety sensors) for each type
of application.
a. Care shall be exercised to reduce the risk of
nuisance tripping, such as when a vehicle trips the
safety sensor while the gate is still moving.
b. One or more non-contact sensors (safety sensors)
shall be located where the risk of entrapment of
obstruction exists, such as the perimeter reachable by
a moving gate or barrier.
10. Never mount any device that operates the gate
opener where the user can reach over, under, around
or through the gate to operate the controls. Controls are
to be placed at least 6’ (1.8m) from any part of the
moving gate.
11. Controls intended to be used to reset an operator
after 2 sequential activations of the entrapment
protection device or devices must be located in the line
of sight of the gate, or easily accessible controls shall
have a security feature to prevent unauthorized use.
Never allow anyone to hang on or ride the gate during
the entire travel of the gate.
12. Each gate opener is provided with two safety
warning placards. The placards are to be installed on
the front and back of the gate where they are plainly
visible. The placards may be mounted using cable ties
through the four holes provided on each placard.
All warning signs and placards must be installed where
visible in the area of the gate.

2
13. To AVOID damaging gas, power, or other
underground utility lines, contact underground utility
locating companies BEFORE digging.
SAVE INSTRUCTION.
14. Do not permit children to play on or around the gate
and keep all controls out of their reach.
Dual Gate Opener Parts List

2
Single Gate Opener Parts List

3
Optional Accessories Parts List
Tools Needed:
·Power Drill ·Tape Measure ·Open End Wrenches - 14# &17# or Adjustable Wrenches
·Wire Strippers ·C-Clamps - small, medium, and large ·Level ·Hacksaw or Heavy Duty Bolt Cutters
·Phillips Screwdriver ·An extra person will be helpful

4
Technical Specifications & Features
Specifications
MK1101/1102
MK1101M/1102M
MK1301/1302
MK1301M/1302M
MK1501M/1502M
Input:
110V~120V/60Hz or 220~240V/50Hz
Motor voltage:
24VDC
Power:
50W each actuator
80W each actuator
100W each actuator
Current:
2A
3A
4A
Actuator speed:
16mm/s
Max. actuator travel:
385mm
485mm
Ambient Temperature:
-20℃~ +50℃ (-4°F to 122°F)
Protection class:
IP44

5
Features:
·Soft start and soft stop
·Emergency release key in case of power failure
·Dual/Single gate running mode
·Adjustable opening/closing interval between master and slave gate
·Stop in case of obstruction during gate opening.
·Reverse in case of obstruction during gate closing.
·Built in adjustable auto-close (0-99 seconds)
·Built in max. Motor running time (MRT) adjustable for multiple safety protection (1-50 seconds)
·Digital display indicates the running situation and setting menu
·Can be equipped with a wide range of accessories
·Reliable electromagnetism limit for easy adjustment
·Easy to install, and minimum maintenance requirement

6
Dual Gate Overview

7
Single Gate Overview
Preparation for Installation
There are two installation types for the gate opener, Pull-to-Open and Push-to-Open.
In the Push-to-Open installation, gate opens out from the property. A Push-To -Open Bracket (PSO part) is
required to be used for each gate.
The gate opener is mounted to the gate and to the gate post. Both round and square posts can be used because
the Post Brackets are curved. When mounting the Post Brackets, use bolts long enough to pass through the entire
post. M10 x 200 bolts are included. Concrete anchors are not provided.
When mounting the Post Brackets to wooden posts, a larger-size washer or metal plate should be used between
the bolts and the wooden post to ensure the stability of the fastening hardware. If the post is smaller than 6"
diameter or square, it should be made of metal and set in cement to ensure its stability.
NOTE: Ensure the gate does not open into public areas.