TownSteel e-Elite 4000 Series Istruzioni operative

TS Smart Cylindrical Lock
e-Elite 5000-BLE

CEM-190327-0496
1
Index
Bluetooth Information······················································ 2
Definitions ····································································3
Factory Default Settings ·················································· 3
Important Notes····························································· 4
Change Master Code······················································ 5
Add Credentials····························································· 5
Add a User Code
Add Multiple User Codes
Add User Keycards
Delete Credentials·························································· 7
Delete User Code
Delete User Keycard
Reset to Factory Default Settings
System Settings····························································· 8
Passage Mode
Verification Mode
Sound
Reset to Factory Default Settings w/o Master Code···············9
Low Battery··································································9

CEM-190327-0496
2
GENERAL LOCK INFORMATION FOR THE BLUETOOTH FUNCTION
APP TS Home
Bluetooth smart lock introduction
2019/04/30
TS Home APP can be used as Admin to manage the door locks and management tasks.
APP functionality
Unlocking
Manage clients
Management unlock key
Query unlock records
Authorize other users to unlock and query unlock records
Operations
1. Download TS Home APP
Search from Apple APP Store or Google Play, download TS Home APP and install:
2. Activate TS Home account
Register as a TS Home user by phone or email address
3. Add a lock

CEM-190327-0496
3
Add a networked device→Bluetooth Door Lock→Press the reset button→Pair with your smart phone→Name the device
→Completed.
4. Add a key
User→Key management→Add key→Password key→Enter new password→Completed
5. Add keycard/Fob
User→Key management→Add key→Keycard→Swipe the touchpad with keycard/Fob to operate the lock→Completed
6. Add a temporary key
User→Key management→Temporary authorization→Add temporary authorization→Temporary password→Enter user
name and expiration date→Send→Completed
7. Authorize other users to lock and query unlock records
Authorize user :More→QR code→Authorization→select authorization type→Permission settings→Completed
Authorized party:Scan QR code→Apply→Completed
8. Unlocking
Click unlock button→Unlocking
9. Modify door lock settings
More→Door lock settings→Open door voice command/combination unlock→ON/OFF
10. Query unlock records
More→Local unlock records→Click to load
11. Bluetooth firmware update
More→Bluetooth firmware update→Found new firmware
12. Unbind the device
More→Unbind device

CEM-190327-0496
4
Definitions
Credential: The lock requires a valid credential to operate. A credential can be a Master Code, User Code, or
Keycard/Fob.
LED Indicator: The LED indicators are located around the keypad of the lock. Lock flashes green LED and/or red LED
dependent on inputs. While unlocking, a red LED followed by a green LED means the lock is not programmed and can
be unlocked with any 6-10 digit code orKeycard/Fobs.
•
Master Code: The Master Code programs all User Codes, Keycards/Fobs (Credentials), and System Settings. The
Factory Default Setting’s Master Code is 123456. This must be changed before programming the lock. Each lock has
one Master Code. Master Code cannot bedeleted.
User Code: User Codes are used to operate the lock. User Codes are programmed by the Master Code. The lock can
have a maximum of 447 User Codes (interchangeable withKeycards/Fobs).
User Keycard/Fob: Keycards or Fobs can be used to operate the lock. Master Code is used to program User
Keycards/Fobs. Swipe the touch keypad with a Keycard/Fob to operate the lock. The lock can have a maximum of447
Keycards/Fobs (interchangeable with User Codes). Any standard Keycard/Fob can be programmed into thelock.
Passage Mode: Door will remain actively unlocked until the Master Code or the Passage Credential isre-entered.
Dual Verification Mode: Two valid credentials are needed to unlock thedoor.
Sound: Keypad sound is enabled by Factory Default Settings. Disabling the sound only affects general operation, not
during programming of the lock. During programming mode, lock will temporarily re-enablesound.
Factory Default Settings
Master Code: 123456
Penalty Time: 1 minute 30 seconds after 5 invalid entries
Passage Mode: Disabled
Dual Verification Mode: Disabled
Sound: Enabled

CEM-190327-0496
5
Important Notes
To wake up the touch keypad from idle mode, gently swipe or tap thekeypad.
While in Factory Default Settings any credential will open the lock until a Master Code is programmed into the lock. When
any credential is presented the lock will flash red and then green andunlock.
•
The Factory Default Setting’s Master Code must be changed before programming any other codes or systemsettings.
A Master Code or User Code can be 6-10 digits (they do not need to be the same codelength).
•
To open the lock using a valid credential – enter a User Code or Master Code followed by Pound (#) or swipe a
Keycard/Fob. This will be followed by a green LED and the lock will open for 5 seconds before automaticallyre-locking.
•
Pressing the Asterisk (✴) key will cancel any on-going code input or programming sequence. Pressing Asterisk (✴) two
times will set the lock on idle.
•
Pressing the Asterisk (✴) key followed by Pound (#) and entering the Master Code opens programming.
•
During programming, allow for the lock’s sounds to end before pressing any keys to make sure the system recognizes
the programming sequence.
During programming, the green LED indicates success and the red LED indicatesfailure.
Outside of programming, the green LED indicates unlocked and the red LED indicateslocked.
To prevent unauthorized entry, the lockout feature is activated for 1 minute 30 seconds after 5 invalid entries. During
lockout, no credential will be accepted. Penalty time is 1 minute and 30 seconds, and the red LED and alarm will operate
repeatedly for the duration of thepenalty.
•
This lock features anti-pry cryptographic functions. Users can add random digits before and/or after a valid code. Entera
valid code in the following method: “XXXCODEXXX(15 digits are the limit)” followed by Pound(#).
Replacing batteries does not change existingsettings.
The symbols
and
are used in this programming guide to represent the audio and visual cues the lock uses to show
successful progression during the programming process.
Disclaimer: The codes used in the following examples are not recommended for actual valid codes - accepted protocol
should be followed for secure codes - repeated strings of numbers are not secure.

CEM-190327-0496
6
Change Master Code
Key Sequence
For example, to change Master Code to “555555”, press:
Notes
•
Factory Default Setting’s Master Code is 123456. It must be changed with the user’s own Master Code immediately.
Manufacturer assumes no liability, direct or indirect, due to failure to change Master Code.
•
No other programming will be accepted until Factory Default Setting’s Master Code has been changed.
Master Code can be changed at any time. Changing the Master Code does not affect other lock settings.
A lock has only one Master Code. Multiple locks can have the same MasterCode.
Add Credentials
Add a User Code
Key Sequence
For example, to add User Code of “202020”, press:

CEM-190327-0496
7
Notes
Add Multiple User Codes
Key Sequence
1st User Code Key Sequence
For example, to add User Codes “202020”, “303030”, and “404040”, press:
The input of additional credentials must start before lock goes into Idle Mode (12 seconds). If the lock goes into Idle Mode, start the
key sequence from the beginning.
Same User Code cannot be added twice.
•
To exit, press asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds).
Add Keycard or Key Fob
Key Sequence
Keycards/Fobs can be added interchangeably with UserCodes.
Multiple Keycards/Fobs can be added during the same programming sequence (like Additional User Codes Key Sequence).
Same Keycard/Fob cannot be programmed twice.
•
To exit, press asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds).
Notes
Additional User Codes Key Sequence:

CEM-190327-0496
8
Delete Credentials
Delete User Codes
Key Sequence
For example, to delete User Code “202020”, assuming the Master Code is “555555”, press:
Delete User Key Cards
Key Sequence
Notes
The Master Code cannot be deleted.
Multiple Keycards/Fobs can be deleted during the same programming sequence (like Additional User Codes Key Sequence).
•
To exit, press the asterisk (✴) or wait until the lock goes into Idle Mode (12 seconds).
Reset Lock to Factory Default Settings
Key Sequence
All credentials will be deleted, and the lock will reset to Factory DefaultSettings.
Notes

CEM-190327-0496
9
System Settings
Passage Mode
Key Sequence
Notes
After creating a Passage Code, entering it will activate the Passage Modefunction.
The lock will remain actively unlocked until the Passage Code or Master Code is entered to deactivate (or Disable) the function.
Dual Verification Mode
Key Sequence
Notes
Dual Verification Mode, when enabled, requires 2 valid credentials to operate thelock.
A credential can be a Master Code, User Code, or Keycard/Fob.
The Factory Default Settings is set to one credential.
Adjust Keypad Sound
Key Sequence
Notes
Disabling the sound only affects general operation, not during programming of thelock.
During programming mode, lock will temporarily re-enablesound.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali TownSteel Serratura

TownSteel
TownSteel E-GENIUS 2000 Series Manuale utente

TownSteel
TownSteel MDE Series Manuale utente

TownSteel
TownSteel e-lite 4000 Series Istruzioni operative

TownSteel
TownSteel Prodigy SmartLock 4000 Series Guida alla risoluzione dei problemi

TownSteel
TownSteel e-Genius 2990 Series Istruzioni operative

TownSteel
TownSteel e-Smart 6000 Series Manuale utente

TownSteel
TownSteel Prodigy SmartLock Interconnect 2000 Series Istruzioni operative

TownSteel
TownSteel XCE 2000 Series Manuale utente

TownSteel
TownSteel e-Genius 2000 Series Manuale utente

TownSteel
TownSteel 2000 Series Guida alla risoluzione dei problemi