TR 900 Manuale utente

Hygiene Equipment
Designed for People
1
Registered at Medical Products Agency,
Sweden as an MDR Class 1 product
according to MDR 2017/745.
TR reserves the right to make design
changes and/or improvements without
notice.
Always study this manual carefully before you
attempt to operate your bathing system. The
operator/user must always have access to the
operating manual.
This bathing system is intended for professional use
only where the patient will be under supervision of
trained personnel.
Operating instructions and recommended
maintenance procedures are explained in the
following pages.
If you have any questions regarding the operation or
maintenance of your bathing system and cannot find
the answer in this manual, please contact us.
The system is designed for years of trouble-free
operation, with proper use and maintenance.
Bathtub and shower water must be run at least every
three days.
Operating manual
Version 202
1
-
04
-
26
TR
900
Height adjustable Bathtub
Warning
Mandatory to read the Operating manual before using the equipment.

Hygiene Equipment
Designed for People
2
Table of contents
Manufacturer
Page
4
Introduction
Page
5
Unpacking
Page
6
Installation
Page
7
Initialization/Calibration
Page 1
2
-
Cleaning injector/mixture
Page 1
2
-
Thermostatic mixer
Page 1
3
Intended use
Page 1
4
Safety Instructions
Page 1
5
-
General safety instructions
Page 1
5
-
In case of an accident
Page 1
7
Features and controls
Page 1
8
-
TR 900 /
-
SS,
-
C,
-
CW
Page 1
8
-
TR 900A
(Autofill) /
-
SS,
-
C,
-
CW
Page 1
9
Product description
Page
20
-
TR 900 /
-
SS,
-
C,
-
CW
Page
20
-
TR 900A (Autofill) /
-
SS,
-
C,
-
CW
Page 2
1
-
Possible combinations
Page 2
2
Technical specification
Page 2
3
User instructions TR 900 /
-
SS,
-
C,
-
CW
Page 2
4
-
How to
fill the tub with water
Page 2
4
-
Showering
Page
2
5
-
Height adjustment
Page 2
6
-
Whirlpool
Page 2
7
-
Cleaning
Page 3
2
User instructions TR 900A (Autofill) /
-
SS,
-
C,
-
CW
Page 2
8
-
How to fill the tub with water
Page 2
8
-
Showering
Page 2
9
-
Height
adjustment
Page
30
-
Whirlpool
Page 3
1
-
Cleaning
Page 3
2
-
Patient handling
–
Ambulatory patients
Page 3
3
-
Patient handling
–
Recumbent patients
Page 3
4
System components
Page 3
5
-
Lifting columns
Page 3
5
-
Thermostatic mixer
Page 3
5
Labels and
symbols
Page 3
6
Routine maintenance
Page 3
8
-
General information / Warranty
Page 38
-
Important information regarding the Thermostatic mixer
Page 39
-
Before every use
Page
40
-
Daily maintenance
Page
40
-
Monthly maintenance
Page
4
1
-
Annual
maintenance
Page 4
2
-
Maintenance every 3 years
Page 4
4
-
Maintenance every 5 years
Page 4
5
-
Maintenance after 10 years
Page 4
6

Hygiene Equipment
Designed for People
3
Table of contents
Cleaning instructions
Page 4
7
-
General cleaning instructions
Page 4
7
-
Cleaning the Whirlpool system
(Option
-
CW, CWA)
Page 4
8
Disposal / Recycling
Page
50
Maintenance record
Page
5
1
Training record
Page 5
2

Hygiene Equipment
Designed for People
4
Manufacturer
TR Equipment AB
Rundelgatan 2
SE-573 35 Tranås
Sweden
www.trequipment.com
Phone: +46 (0)140 38 50 60
Group subsidiaries:
USA
TR Group Inc. Phone: +1 (800) 7526900
www.trequipment.com
information@trequipment.com
United Kingdom:
TR Equipment Ltd Phone: +44 (0) 844 335 8386
www.trequipment.com
Germany:
TranspoRehamed GmbH Phone: +49 (0) 212-645850-0
www.transporehamed.de

Hygiene Equipment
Designed for People
5
Introduction
Dear Customer,
Thank you for choosing one of our quality products. We hope you enjoy the TR 900 bathtub.
This manual shall, in conjunction with staff training, ensure that the operator/user is always using and/or
operating the TR 900 correctly.
New colleagues must be trained by qualified and experienced staff.
TR Equipment AB requires that each user has read and understands the entire operating manual and that
they can apply the instructions as specified. This applies to anyone who was not present at the in-service.
This instruction manual should generally be kept easily accessible for every user. Copying the whole manual is
encouraged since its sole purpose is to improve the standard of training and safety.
Please order another copy from us if the instruction manual is lost or unusable, or if it has become illegible
over time.
If you need further information, do not hesitate to contact TR Equipment AB or one of our qualified partners.
Warning
Mandatory to read the Operating manual before using the equipment.
Warning
Make sure you have read, understood, and applied the information on the following pages
before using the bathtub.

Hygiene Equipment
Designed for People
6
Unpacking
When you receive a TR 900 bathtub from us it’s placed on a pallet surrounded by a wooden crate wrapped in
plastic. Start unpacking by carefully cut and remove the plastic. DO NOT use any sharp tools that may scratch
the bathtub.
Unscrew the wooden crate from the pallet.
Carefully lift the wooden crate away from the pallet. When lifted, do so briefly and use at least two people.
We advise to use the transport Wheel beam and ramp (Options) to get the bathtub off the pallet and to get the
bathtub in place.
Place the Wheel beam under the chassis. Position the Wheel beam just behind the adjustable feet.
Carefully
roll the tub off the pallet.

Hygiene Equipment
Designed for People
7
Installation instructions
The TR 900 bathtub is delivered fully assembled, ready to be connected to water and power supply at the
customer’s premises and should be installed according to local guidelines and regulations.
When the bathtub is in place adjust the adjustable feet to get the
bathtub chassis in level (Blue line).
The tub must be cleaned before the first use!
Bathroom layout
Recommended room size is 2400mm x 3000mm, or larger.
Plumbing
TR900 is delivered with an installation kit containing 2pcs 500mm connecting hoses R20, 2pcs ball valves
R20, and 2pcs check valves. DO NOT bend the connecting hoses.
If your TR900 is equipped with a cleaning unit, the installation kit contains 1pcs 500mm connecting hose R15
and 1pcs check valve. DO NOT bend the connecting hose.
Installation of the bathtub shall be performed by certified plumber according to national/local regulations.
To eliminate pipe debris, it is essential that supply pipes are thoroughly flushed before the bathtub is being
connected. The drainage hose shall be connected to floor- or wall drainage. To level the bathtub, adjust the
adjustable feet.
Autofill
Set the shower flowrate by adjusting the ball valve inside the panel. The ball valve is located on the pipes of
the shower unit inside the panel.
Installation kit
R20
Hot
-
and Cold Water
Installation kit
R15
Cleaning unit
Warning
The bathtub may only be used after it has been successfully and correctly installed.

Hygiene Equipment
Designed for People
8
Installation instructions
Electrical
The bathtub is designed for 100-120V – 50/60Hz, 10A or 220/240V – 50/60Hz, 10A.
The control box for the lifting actuator is specified for 110-230VAC, +/-10%.
Voltage outside these norms will damage the linear actuator and control box.
The bathtub must be connected to the mains via a cord that is connected to a GFCI, Ground Fault Circuit
Interrupter, including an easily accessible switch near the bathtub (Not supplied by TR Equipment).
Warning
Polarity and grounding must be correct. Improper connection may result in injury.
Warning
The bathtub may only be used after it has been successfully and correctly installed.
All electric conduit, fitting and wiring to bath supplied must be installed by a certified
electrician in accordance with national/local regulations. Main switch, main fuse and Ground
Fault Circuit Interrupter are NOT included at delivery and must be supplied by others.

Hygiene Equipment
Designed for People
9
Installation instructions

Hygiene Equipment
Designed for People
10
Installation instructions
Questo manuale è adatto per i seguenti modelli
3
Indice
Altri manuali TR Vasca
Manuali Vasca popolari di altre marche

Lyons
Lyons Elite ETLxx663219 Series Manuale utente

Woodbridge
Woodbridge BJ500 Istruzioni per il montaggio

Whirlpool
Whirlpool Ariel ARL-702 Manuale utente

TEIKO
TEIKO EXCELLENT DUO Manuale utente

American Standard
American Standard Colony 5-1/2' x 32" Manuale utente

American Standard
American Standard 3052OD.X0X Guida rapida