Walking the Zone to Commission Installation
1. Rotate the lux knob fully clockwise for daylight operation, set the time control to min
(Anti-clockwise) and the sensitivity to maximum (clockwise).
2. Turn on the power at the isolating switch. The load device should turn on for a short
period of time.
3. Wait 30 seconds for the circuit to stabilise.
4. If not already adjusted, direct the sensor toward the desired area, adjusting the elbow
joint on the sensor arm. Loosen all nuts on sensor before adjusting.
5. Have another person move across the centre of the detection area and slowly adjust the
angle of the sensor arm until the light is switched on. Your sensor is now aimed at your
selected area.
6. Adjust the time control to the desired level.
7. Adjust the sensitivity (if required) to limit detection range. This can be tested via walk
testing.
8. Adjust the lux control by rotating anti-clockwise to revert to night time operation. If the
lights are required to switch on earlier, e.g. dusk; wait for the desired light level, and
slowly turn the lux knob clockwise while someone walks across the centre of the detection
area. When the lights switch on, release the lux control knob.
Manual Override Feature
When the power is initially turned ON, the fitting operates in AUTO mode. In this mode, the
sensor turns the light ON and OFF automatically.
The manual override function means that the fitting can be put permanently “ON”. In this
mode the PIR sensor is disabled.
Resetting the Fitting into “Manual Mode”
9. To bypass the “auto mode” and set the fitting into “manual mode”, turn the wall switch
“OFF” and “ON” once within 3 seconds.
Wall switch action: OFF ON
10. Wait for 3 seconds and the light will turn “ON” permanently and the fitting will be in the
“manual mode”.
Note: If the wall switch action is done more than twice, the fitting may not enter into “manual mode”.
Setting the Fitting into “Auto Mode”
1. To change back to “auto mode”, turn the power “OFF” and wait for about 10 seconds,
then turn it back “ON” again turning the switch “ON” once only.
Wall switch action: OFF, wait 10 seconds ON
2. The PIR sensor will enter into the “Warm-up” mode and the lights will stay “ON” for 10
seconds, then will turn “OFF”.
3. Now wait for about 10 seconds for the circuit to stabilise and the fitting will operate now
in “auto mode”.
Warning: The manual override is linked with the lux setting, and switching on the manual
override will only function at night if the sensor settings are set to functioning in the dark.
It will only work during the day if the lux level is set to daylight.