MODEL A ORGANS
7. Temporarily position the SSP-1C chassis on the
mounting pan. The shielded wire should be facing the
right and the edge of the right mounting flange should
be about 1-1/2" in from the end of the pan. Mark the
pan with the location of the 2 small mounting holes on
each mounting flange. Drill a 7/64" hole at each mark.
8. Secure the SSP-1C to the mounting pan with 4) #6 x
1/4" sheet metal screws.
9. Reinstall the mounting pan on the two support brackets
using 2) #8-32 x 3/8" screws, along with original
lockwashers and nuts at each end.
10. Route the SSP-1C shielded cable into the rheostat box. Solder the inner conductor to the lug where the original red wire
was soldered. Solder the shield to the ground lug where the original black wire was soldered. Replace rheostat box
cover.
11. Mate one wire of the SSP-1C zip cord with the AC wires grouped in step 1 using a yellow wire nut. Mate the remaining
wire of the zip cord with the AC wires grouped in step 2 using a yellow wire nut.
NOTE: The terminal strip on the SSP-1C allows easy connection of the output and tremolo control wires. Each wire should
have approximately 5/16" of insulation removed. Wires are attached by loosening (but not removing) the terminal screw,
placing the wire under the clamping bar, and re-tightening the screw.
NOTE: This pre-amp contains all necessary switching circuitry for 122 and similar type Leslie tone cabinets.
12. If a 122 type Leslie is being used, remove the Leslie 8,000 kit from organ (if present). Attach one of the tremolo switch
wires to the LC terminal. Attach the second tremolo switch wire to the end GND terminal.
13. If a 122 type Leslie is being used, connect its red and black signal wires to the G1 and G2 terminals. Connect its ground
wire to the GND terminal.
14. If a Hammond tone cabinet is being used, connect its red and black signal wires to the G3 and G4 terminals. Connect its
ground wire to the GND terminal.
15. Dress all leads and secure where necessary with supplied twist ties. Re-connect AC power to organ.
16. Adjust tone control to customer preference.
This completes normal installation.
ALL OTHER MODELS
Install a plastic spacer in each of the 2 large holes in the
right SSP-1C mounting flange. Position the SSP-1C
chassis on the channel so that the left mounting flange is
over the left two threaded mounting posts. Secure using
2) #8-32 x 3/8" screws. On organs with a chorus
generator, it may be necessary to move the oil tube
slightly for clearance.
Place a sheet of paper under the channel to catch any
metal chips. Through each of the plastic spacers,
carefully drill a 7/64" hole through the channel.
Secure the right end of the SSP-1C with 2) #6 x 3/4"
sheet metal screws.
-2-