Tritech 0747-SOM-00002 Manuale utente

0747-SOM-00002-01 Page 1 of 28
Diver Mounted Display
(Tethered)
Product Manual
0747-SOM-00002

0747-SOM-00002-01 Page 2 of 28
Table of Contents
Help & Support .........................................................................................................................................................3
Warning Symbols.....................................................................................................................................................4
Introduction...............................................................................................................................................................5
General Overview.....................................................................................................................................................5
Technical Specification..........................................................................................................................................6
Physical Dimensions 1200ik & 720ik..................................................................................................................6
DMD SCU Specifications........................................................................................................................................7
Monocle Specifications..........................................................................................................................................8
Subsea Computer (SSC) Specifications............................................................................................................9
Tether Specifications..............................................................................................................................................9
Hardware Installation & Configuration.............................................................................................................10
DMD SCU..................................................................................................................................................................10
DMD Instrument Deployment Case...................................................................................................................13
DMD Sonar Deployment Case ............................................................................................................................15
DMD Diver to Surface - Deployment Case.......................................................................................................16
System Connections –SUBSEA........................................................................................................................17
System Connections –SURFACE .....................................................................................................................18
Assembly & Fitting of Sonar onto Mask (Using the OTS Accessory Rails)...........................................19
Assembly & Fitting of Monocle onto Mask (Using the OTS Accessory Rails) ......................................20
Monocle Orientation..............................................................................................................................................22
Power Up –System Switch On...........................................................................................................................23
Switch ON & Start-Up Sequence........................................................................................................................23
Software Display & Operation ............................................................................................................................25
Operational notes...................................................................................................................................................26
Dual Frequency Options ......................................................................................................................................26
System Power Down & Stowage........................................................................................................................28
Specifications for storage after unpacking.....................................................................................................28

0747-SOM-00002-01 Page 3 of 28
Help & Support
First please read this manual thoroughly (particularly the Troubleshooting section, if present). If a warranty
is applicable, further details can be found in the Warranty Statement, 0080- STF-00139, available upon
request.
Tritech International Ltd can be contacted as follows:
Mail
Tritech International Ltd
Peregrine Road
Westhill Business Park
Westhill, Aberdeenshire
AB32 6JL, UK
Telephone
+44(0)1224 744 111
Email
tritech-support@moog.com
Website
www.moog.com/tritech
Prior to contacting Tritech International Ltd please ensure that the following is available:
1. The Serial Numbers of the product and any Tritech International Ltd equipment connected directly or
indirectly to it
2. Software or firmware revision numbers
3. A clear fault description
4. Details of any remedial action implemented
Contamination
If the product has been used in a contaminated or hazardous environment you must de-contaminate the
product and report any hazards prior to returning the unit for repair. Under no circumstances should a
product be returned that is contaminated with radioactive material.
The name of the organisation which purchased the system is held on record at Tritech International Ltd and
details of new software or hardware packages will be announced at regular intervals. This manual may not
detail every aspect of operation and for the latest revision of the manual please refer to
www.moog.com/tritech
Tritech International Ltd can only undertake to provide software support of systems loaded with the
software in accordance with the instructions given in this manual. It is the customer's responsibility to
ensure the compatibility of any other package they choose to use.

0747-SOM-00002-01 Page 4 of 28
Warning Symbols
Throughout this manual the following symbols may be used where applicable to denote any particular
hazards or areas which should be given special attention:
Note
This symbol highlights anything which would be of particular interest to
the reader or provides extra information outside of the current topic.
Important
When this is shown there is potential to cause harm to the device due to
static discharge. The components should not be handled without
appropriate protection to prevent such a discharge occurring.
Caution
This highlights areas where extra care is needed to ensure that certain
delicate components are not damaged.
Warning
DANGER OF INJURY TO SELF OR OTHERS
Where this symbol is present there is a serious risk of injury or loss of
life. Care should be taken to follow the instructions correctly and also
conduct a separate Risk Assessment prior to commencing work.

0747-SOM-00002-01 Page 5 of 28
Introduction
General Overview
The DMD system has been designed to provide divers with the ability to navigate and carry out inspections
in zero visibility conditions.
Utilising the Gemini range of Multibeam imaging sonars allows the user to select the most suitable sonar for
the type of operation required. Employing a high degree of resolution and field of view the diver can opt for
either the Gemini 720ik or Gemini 1200ik Multibeam imaging sonars, both provide excellent range,
resolution and field of view. These high specification Multibeam imaging sonars provide a diver with a high
degree of confidence while working in zero visibility conditions and allow searches to be undertaken far
more efficiently than using conventional search pattern techniques. The DMD systems have been designed
to be used with the Inodive accessory rail system, allowing for the DMD system to be used with an
extensive range of dive masks and helmets. All of the Gemini sonars, when supplied with a DMD system,
are built-up with an Inodive interface to allow for seamless installation onto the dive mask/helmet.
Power and control of the DMD system can either be through a tethered connection to the surface, where
the topside operator controls what the diver sees, or the diver can work autonomously with no need for a
surface connection by utilising a diver battery pack and DMD hand controller.
The tethered system (DMD-T) is intended primarily for surface air dive systems where the supplied tether
connects the diver to the surface and control of the sonar is undertaken by the support team. The same
DMD-T system can be used by scuba divers, where it’s acceptable to be attached to the surface by the
tether.
The untethered system (DMD-U) allows the diver to operate totally independent of a surface connection,
with the diver himself taking control of the sonar operation. This is of particular benefit where a diver wishes
to operate in a covert fashion or where there may be hazards that the tether could get snagged on.
By using the DMD system, a diver has the ability to view the sonar image on the diver mounted monocle,
allowing the diver to quickly and efficiently locate targets of interest. The DMD-U system allows the diver to
adjust settings using a custom hand controller and record data of interest on the subsea computer, while
the DMD-T system allows the support diver on the surface to make any necessary adjustments to the sonar
settings and highlight any targets of interest for the diver to investigate.
The Inodive rail system simplifies the fitting and removal of the DMD system. This allows the sonar to be
removed from the mask/helmet and attached to a Gemini sonar pistol grip where this may at times offer
some advantage, such as difficult to reach areas or where a different sonar viewing angle may be
beneficial.
The innovative Monocle design allows for it to be accurately positioned on the divers helmet/mask and yet it
can also easily be lifted out of the divers view and later replaced back into the same position by the diver
when it’s required.

0747-SOM-00002-01 Page 6 of 28
Technical Specification
The system is designed to be used with our Gemini range of multibeam sonars –primarily the
1200ik with inodive mounting plate
720ik with inodive mounting plate
Physical Dimensions 1200ik & 720ik
Please refer to the 1200ik & 720ik manuals available on our website www.tritech.co.uk for full sonar
specifications

0747-SOM-00002-01 Page 7 of 28
DMD SCU Specifications
Surface Control Unit (SCU)
(only used with DMD-T)
SCU Rugged Case
Laptop - Toughbook 55
Power
Internal rechargeable power
Internal rechargeable battery
Duration of operation
>4hrs (for a dual battery system)
Up to 19 hours
IP rating
Weatherproof
IP53
Battery chemistry
Li-ion
Li-ion
Weight in air
8kg (plus laptop)
2kg

0747-SOM-00002-01 Page 8 of 28
Monocle Specifications
Monocle specification
Power requirement
0.5W @ +5V DC
Depth rating
100m
Display input
RGB, HSYNC, VSYNC
Display resolution
SVGA (800 X 600)
Connector
SubConn Micro Circular series
Weight in water
0.09kg

0747-SOM-00002-01 Page 9 of 28
Subsea Computer (SSC) Specifications
Subsea computer
Power requirement *1
10W @ 20 - 42 VDC
Depth rating
100m
Connectors
SubConn Micro Circular series
Weight in water
0.54kg
*1Does not allow for attached accessories
Tether Specifications
Tether (only used with DMD-T)
Cable length
100m
Connectors
SubConn Micro Circular series
Weight in water
0.073kg(per meter)

0747-SOM-00002-01 Page 10 of 28
Hardware Installation & Configuration
The full DMD system is contained within 4 separate rugged deployment transit cases
These are
DMD SCU
DMD Instrument Deployment Case
DMD Diver to Surface –Deployment Case
DMD Sonar Deployment Case
DMD SCU
The DMD SCU case is a self-contained rugged transit case featuring integrated connection points on its
rear which provide all the surface connections required which power run and deploy the system onto a
diver. Securely mounted within the DMD SCU are x2 Li-ion battery packs linked into an intelligent charging
circuit.
To comply with IATA shipping regulations the Toughbook laptop should not be retained within the
DMD SCU when the unit is presented for international air transportation. The ‘Air Transportation Fuses’ at
F1 & F2 on the rear of the SCU should be removed and stored separately (this will isolate the Li-Ion
batteries). The Toughbook should be shipped separately within a purpose defined space contained within
the DMD Instrument Deployment case
Earth Connection Tab
Audio Comms Pass thru
Main Tether Connection
Transportation fuses
DC power Input
Indice