Trotec PCPS 11-20V Manuale utente

TRT-BA-PCPS11-20V-PCPS12-20V-TC2021-23-002-EN
PCPS 11-20V / PCPS 12-20V
EN
ORIGINAL INSTRUCTIONS
CORDLESS COMPRESSOR AND
CORDLESS AIR PUMP

2 EN
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Table of contents
Notes regarding the instructions ..........................................2
Safety .....................................................................................2
Information about the device................................................6
Transport and storage...........................................................8
Start-up..................................................................................9
Operation .............................................................................12
Available accessories..........................................................14
Errors and faults..................................................................14
Maintenance ........................................................................15
Disposal ...............................................................................16
Declaration of conformity ...................................................16
Notes regarding the instructions
Symbols
Warning of electrical voltage
This symbol indicates dangers to the life and health of
persons due to electrical voltage.
Warning of explosive substances
This symbol indicates dangers to the life and health of
persons due to potentially explosive substances.
Warning
This signal word indicates a hazard with an average
risk level which, if not avoided, can result in serious
injury or death.
Caution
This signal word indicates a hazard with a low risk
level which, if not avoided, can result in minor or
moderate injury.
Note
This signal word indicates important information (e.g.
material damage), but does not indicate hazards.
Info
Information marked with this symbol helps you to carry
out your tasks quickly and safely.
Follow the manual
Information marked with this symbol indicates that the
instructions must be observed.
Wear hearing protection
Information marked with this symbol indicates that you
should wear hearing protection.
You can download the current version of the instructions and
the EUdeclaration of conformity via the following link:
PCPS 11-20V
PCPS 12-20V
https://hub.trotec.com/?id=45184
Safety
General Power Tool Safety Warnings
Warning
Read all safety warnings, instructions, illustrations
and specifications provided with this power tool.
Failure to follow all instructions listed below may result
in electric shock, fire and/or serious injury.
Save all warnings and instructions for future
reference.
The term power tool in the warnings refers to your mains-
operated (corded) power tool or battery-operated (cordless)
power tool.
General Power Tool Safety Warnings– Work area
safety
•Keep work area clean and well lit. Clutter or dark areas
invite accidents.
•Do not operate power tools in explosive atmosphere,
such as in the presence of flammable liquids, gases or
dust. Power tools create sparks which may ignite the dust
or fumes.
•Keep children and bystanders away while operating a
power tool. Distractions can cause you to lose control.
General Power Tool Safety Warnings– Electrical
safety
•Power tool plugs must match the outlet. Never modify
the plug in any way. Do not use any adapter plugs with
earthed (grounded) power tools. Unmodified plugs and
matching outlets will reduce risk of electric shock.
•Avoid body contact with earthed or grounded surfaces,
such as pipes, radiators, ranges and refrigerators.
There is an increased risk of electric shock if your body is
earthed or grounded.

EN 3
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
•Do not expose power tools to rain or wet conditions.
Water entering a power tool will increase the risk of
electric shock.
•Do not abuse the cord. Never use the cord for carrying,
pulling or unplugging the power tool. Keep cord away
from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electric shock.
•When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
•If operating a power tool in a damp location is
unavoidable, use a residual current device(RCD)
protected supply. Use of an RCD reduces the risk of
electric shock.
General Power Tool Safety Warnings– Personal
safety
•Stay alert, watch what you are doing and use common
sense when operating a power tool. Do not use a
power tool while you are tired or under the influence of
drugs, alcohol or medication. A moment of inattention
while operating power tools may result in serious personal
injury.
Use personal protective equipment. Always
wear eye protection. Protective equipment such
as a dust mask, non-skid safety shoes, hard hat or
hearing protection used for appropriate conditions
will reduce personal injuries.
•Prevent unintentional starting. Ensure the switch is in
the off-position before connecting to power source
and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or
energising power tools that have the switch on invites
accidents.
•Remove any adjusting key or wrench before turning
the power tool on. A wrench or a key left attached to a
rotating part of the power tool may result in personal
injury.
•Do not overreach. Keep proper footing and balance at
all times. This enables better control of the power tool in
unexpected situation.
•Dress properly. Do not wear loose clothing or
jewellery. Keep your hair and clothing away from
moving parts. Loose clothes, jewellery or long hair can be
caught in moving parts.
•If devices are provided for the connection of dust
extraction and collection facilities, ensure these are
connected and properly used. Use of dust collection can
reduce dust-related hazards.
•Do not let familiarity gained from frequent use of tools
allow you to become complacent and ignore tool
safety principles. A careless action can cause severe
injury within a fraction of a second.
General Power Tool Safety Warnings– Power tool
use and care
•Do not force the power tool. Use the correct power tool
for your application. The correct power tool will do the
job better and safer at the rate for which it was designed.
•Do not use the power tool if the switch does not turn it
on and off. Any power tool that cannot be controlled with
the switch is dangerous and must be repaired.
•Disconnect the plug from the power source and/or
remove the battery pack, if detachable, from the power
tool before making any adjustments, changing
accessories, or storing power tools. Such preventive
safety measures reduce the risk of starting the power tool
accidentally.
•Store idle power tools out of the reach of children and
do not allow persons unfamiliar with the power tool or
these instructions to operate the power tool. Power
tools are dangerous in the hands of untrained users.
•Maintain power tools and accessories. Check for
misalignment or binding of moving parts, breakage of
parts and any other condition that may affect the
power tool's operation. If damaged, have the power
tool repaired before use. Many accidents are caused by
poorly maintained power tools.
•Keep cutting tools sharp and clean. Properly maintained
cutting tools with sharp cutting edges are less likely to
bind and are easier to control.
•Use the power tool, accessories and tool bits etc. in
accordance with these instructions, taking into
account the working conditions and the work to be
performed. Use of the power tool for operations different
from those intended could result in a hazardous situation.
•Keep handles and grasping surfaces dry, clean and
free from oil and grease. Slippery handles and grasping
surfaces do not allow for safe handling and control of the
tool in unexpected situations.
General Power Tool Safety Warnings– Battery tool
use and care
•Recharge only with charger specified by the
manufacturer. A charger that is suitable for one type of
battery pack may create a risk of fire when used with
another battery pack.

4 EN
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
•Use power tools only with specifically designed battery
packs. Use of any other battery packs may create a risk of
injury and fire.
•When battery pack is not in use, keep it away from
other metal objects, like paper clips, coins, keys, nails,
screws or other small metal objects, that can make a
connection from one terminal to another. Shorting the
battery terminals together may cause burns or a fire.
•Under abusive conditions, liquid may be ejected from
the battery; avoid contact. If contact accidentally
occurs, flush with water. If liquid contacts eyes,
additionally seek medical help. Liquid ejected from the
battery may cause irritation or burns.
•Do not use a battery pack or tool that is damaged or
modified. Damaged or modified batteries may exhibit
unpredictable behaviour resulting in fire, explosion or risk
of injury.
•Do not expose a battery pack or tool to fire or
excessive temperature. Exposure to fire or temperature
above 130°C may cause explosion.
•Follow all charging instructions and do not charge the
battery pack or tool outside the temperature range
specified in the instructions. Charging improperly or at
temperatures outsides the specified range may damage
the battery and increase the risk of fire.
General Power Tool Safety Warnings– Charger use
and care
•This charger can be used by children aged
from8years and above and persons with reduced
physical, sensory or mental capabilities or lack of
experience and knowledge if they have been given
supervision or instruction concerning use of the
appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
•Never insert non-rechargeable batteries into the
charger. A charger that is suitable for one type of battery
pack may create a risk of fire and explosion, when used
with another battery pack or non-rechargeable batteries.
• Only charge the Li-Ion battery "Multiflex20–
2.0DC" (capacity of 2.0 Ah= 5 battery cells) with the
charger "Multiflex 20– 2.0 AC". The battery voltage must
match the battery charging voltage of the charger.
General Power Tool Safety Warnings– Service
•Have your power tool serviced by a qualified repair
person using only identical replacement parts. This will
ensure that the safety of the power tool is maintained.
•Never service damaged battery pack. Service of battery
packs should only be performed by the manufacturer or
authorized service providers.
Intended use
Only use the device PCPS 11-20V for:
• for inflating car tyres, bicycle tyres, inflatable toys, sports
equipment and beach items
• for measuring the current pressure level of an inflatable
object
whilst adhering to the technical data.
Info
Please note that the pressure gauge is not calibrated.
Only use the device PCPS 12-20V for:
• for inflating and deflating common inflatables with a large
volume such as air mattresses, swimming pools, rubber
dinghies or camping equipment
whilst adhering to the technical data.
We recommend using the power tool with original Trotec
accessories.
Foreseeable misuse
The device PCPS 12-20V is not intended for inflating bicycle or
car tyres.
Any other use than the one described in the chapter "Intended
use" is regarded as reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
• have read and understood the instructions, especially the
Safety chapter.
Safety signs and labels on the battery and the charger
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.

EN 5
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
The following safety signs and labels are attached to the
battery:
Warning of explosion risk!
These symbols indicate the following:
Do not expose the battery pack or tool to fire or
excessive temperature! Do not let the battery come into
contact with water or fire! Avoid direct sunlight and
moisture. There is a risk of explosion!
Never charge the battery at ambient temperatures
below10°C or above40°C. Charging improperly or at
temperatures outsides the specified range may damage
the battery and increase the risk of fire.
Observe the correct disposal of the battery!
This symbol indicates the following:
Ensure that the battery is disposed of correctly and
never dispose of it in waste water or public waters.
The battery contains irritating, caustic and toxic
substances that pose significant risks to people and the
environment.
The following safety signs and labels are attached to the
charger:
This symbol indicates the following:
Read the instructions or operating manual before
charging the battery.
This symbol indicates the following:
Only use the charger for charging the battery in dry
interior spaces. Do not charge the device outdoors.
Personal protective equipment
Wear hearing protection.
Excessive noise can lead to hearing loss.
Residual risks
Warning of electrical voltage
Electric shock from insufficient insulation.
Check the device for damages and proper functioning
before each use.
If you notice damages, no longer use the device.
Do not use the device when the device or your hands
are damp or wet!
Warning of electrical voltage
Work on the electrical components must only be
carried out by an authorised specialist company!
Warning of electrical voltage
Before any work on the device, remove the mains plug
from the mains socket and the battery from the device!
Hold onto the mains plug while pulling the power cable
out of the mains socket.
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
Warning of explosive substances
Do not expose the battery to temperatures
above 45°C! Do not let the battery come into contact
with water or fire! Avoid direct sunlight and moisture.
There is a risk of explosion!
Warning
Dangers can occur at the device when it is used by
untrained people in an unprofessional or improper way!
Observe the personnel qualifications!
Warning
The device is not a toy and does not belong in the
hands of children.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
Caution
Keep a sufficient distance from heat sources.
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Note
The device is not suitable for continuous operation. To
prevent overheating, the device must not be used non-
stop for more than 10minutes(PCPS 11-20V)
or 20minutes(PCPS 12-20V).
Should the device be overheating nonetheless, remove
the battery.
Allow the device to cool down sufficiently before
switching it back on.
Behaviour in the event of an emergency/ emergency
stop function
Emergency stop:
Removing the battery results in the function of the device
stopping immediately. Leave the battery out in order to secure
the device against accidental switch-on.

6 EN
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Behaviour in the event of an emergency:
1. Switch the device off.
2. In the event of an emergency, remove the battery from the
device: Hold the release button of the battery and pull the
battery off the device as described in chapter "Removing
the battery".
3. Do not insert the battery if the device is defective.
Information about the device
Device description
The cordless compressor PCPS 11-20V is suited for blowing up
bicycle tyres, car tyres as well as inflatable toys or sports
equipment such as footballs.
The device is equipped with an integrated pressure gauge.
Upon reaching the desired pressure value, the device will be
switched off automatically.
The cordless air pump PCPS 12-20V is suited for inflating and
deflating inflatable products with a large volume such as air
mattresses or rubber dinghies.
Device depiction
Cordless compressor PCPS 11-20V
1
2
3
4
3
5
6
7
8
9
No. Designation
1Mount for valve adapters
2Handle
3Air inlet
4Mount for compressed-air hose
5Control panel
6Battery holder
7On/off switch
8LED work light
9Union nut
Cordless air pump PCPS 12-20V
10
11
12
13
14
15
No. Designation
10 Air inlet (deflating)
11 Handle
12 Battery holder
13 On/off switch
14 LED work light
15 Air outlet (inflating)

EN 7
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Accessories
16
27
28
17
18
26
25
24
23 22
19
20
21
No. Designation
16 Battery
17 Quick charger
18 Red battery LED (battery charging)
19 Nozzle attachments for air pump
20 Compressed-air hose with threaded connector
21 Presta valve adapter
22 Dunlop valve adapter
23 Ball needle
24 Universal adapter, short (2pieces)
25 Universal adapter, long
26 Green battery LED (quick charger ready for operation)
27 3-stage battery level indication
28 Release button
Scope of delivery
• 1 x Cordless compressor PCPS 11-20V
• 1 x Cordless air pump PCPS 12-20V
• 1x Rechargeable battery
• 1x Quick charger
• 1x Compressed-air hose with threaded connector
• 1x Dunlop valve adapter
• 1x Presta valve adapter
• 1x Ball needle
• 1x Universal plastic adapter with 3nozzle attachments for
air pump
• 2x Universal adapter, short
• 1x Universal adapter, long
• 1 x Transport case
• 1x Manual
Technical data
Parameter Value
Model PCPS11-20V PCPS12-20V
Nominal voltage 20 V 20 V
Max. pressure 7bar (100psi) -
Max. air flow rate - 70 m³/h
Weight 1.2 kg 1 kg
Battery Multiflex20 – 2.0 DC
Type Li-ion
Nominal voltage 20 V
Nominal capacity 2.0Ah
Rechargeable cells 5cells
Capacity 40Wh
Quick charger Multiflex20 – 2.0 AC
Input
Nominal voltage 230 – 240 V / 50 Hz
Power consumption 65 W
Output
Nominal voltage 21.5 V
Charging current 2.4 A
Fusing 3.15A (slow-blowing)
Charging time 1 h
Cable length 1.5 m
Protection class II /
Vibration information according to EN62841
Vibration emission
valueah
Uncertainty K
2.6 m/s²
1.5 m/s²
0.3 m/s²
1.5 m/s²
Sound values according to EN62841
Sound pressure
level LpA
85 dB(A) 82 dB(A)
Sound power
level LWA
96 dB(A) 93 dB(A)
Uncertainty KWA 3 dB(A) 3 dB(A)

8 EN
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Wear hearing protection.
Excessive noise can lead to hearing loss.
Information on noise and vibration:
• The specified total vibration and noise emission values
were measured by means of a test procedure standardized
in EN62841 and can be consulted for the comparison of
one power tool with another.
• The specified total vibration and noise emission values
can also be used for preliminary load assessment.
• The actual vibration and noise emission may differ from
the stated values during operation of the power tool. This
depends on how the power tool is used and especially on
the type of workpiece being processed. Try to keep the
vibration load to a minimum. Exemplary measures for
reducing the vibration load include wearing gloves during
operation of the tool and the limitation of working hours.
All parts of an operating cycle must be considered for this
(e.g. times at which the power tool is switched off and
times when it is switched on but runs without load).
Transport and storage
Note
If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.
Transport
For transporting the device, use the transport case included in
the scope of delivery in order to protect the device from external
influences.
Before transporting the device, observe the following:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable of
the charger out of the mains socket.
• Allow the device to cool down.
• Remove the battery from the device.
The supplied Li-ion batteries are subjects to the requirements of
dangerous goods legislation.
Observe the following when transporting or shipping Li-ion
batteries:
• The user may transport the batteries by road without any
additional requirements.
• If transport is carried out by third parties (e.g. air transport
or forwarding company), special requirements as to
packaging and labelling must be observed. This includes
consulting a dangerous goods specialist when preparing
the package.
– Only ship batteries if their housing is undamaged.
– Mask open terminals with tape and pack the battery in
a way that it cannot move inside the packaging.
– Please also observe any other national regulations.

EN 9
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Storage
Before storing the device, observe the following:
• Switch off the device.
• Hold onto the mains plug while pulling the power cable of
the charger out of the mains socket.
• Allow the device to cool down.
• Remove the battery from the device.
• Clean the device as described in the Maintenance chapter.
• For storing the device, use the transport case included in
the scope of delivery in order to protect the device from
external influences.
• Do not store Li-ion batteries which are completely
discharged. Storing discharged batteries can lead to a
deep discharge and thus damage the battery.
When the device is not being used, observe the following
storage conditions:
• Dry and protected from frost and heat
• Ambient temperature below 45°C
• Protected from dust and direct sunlight inside the transport
case
Start-up
Unpacking the device
• Take the transport case out of the packaging.
Warning of electrical voltage
Electric shock from insufficient insulation.
Check the device for damages and proper functioning
before each use.
If you notice damages, no longer use the device.
Do not use the device when the device or your hands
are damp or wet!
• Check the contents of the transport case for completeness
and look for damages.
Warning
Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.
• Dispose of the packaging material according to the
national regulations.
Charging the battery
Note
The battery can be damaged in case of improper
charging.
Remove the charger's mains plug before inserting or
removing the battery.
Never charge the battery at ambient temperatures
below 10°C or above 40°C.
The battery is partially charged upon delivery to avoid damage
to the battery caused by a deep discharge.
Prior to initial start-up and when the battery is low (only the red
LED in the battery level indication(27) is illuminated), the
battery should be charged. To do so, please proceed as follows:
1. Slide the battery(16) onto the quick charger(17) upside
down until it locks in place.
1 h
16
27
17
26
18
2. Insert the mains plug of the quick charger(17) into a
properly fused mains socket.
ðThe red battery LED(18) lights up.
ðCharging requires approx. one hour.
3. Wait until the red battery LED(18) goes off and the green
battery LED(26) lights up.
ðThe battery(16) is fully charged.
4. Hold onto the mains plug while pulling the power cable of
the quick charger(17) out of the mains socket.
ðThe battery(16) and the quick charger(17) may have
become warm during charging.
Allow the battery(16) to cool down to room
temperature.
5. Take the battery(16) out of the quick charger(17) by
pressing and holding the release button(28) and pulling
the battery(16) off the quick charger(17).

10 EN
cordless compressor and cordless air pump PCPS 11-20V / PCPS 12-20V
Inserting the battery
1. Slide the battery(16) onto the device until it locks in place.
16
28
Removing the battery
1. Detach the battery(16) from the device by pressing and
holding the unlocking button(28, I.) and pulling the battery
off the device(II.).
I.
II.
2. If required, charge the battery(16) as described in the
section Charging the battery.
Checking the battery status
The battery comes with an integrated battery level indication.
The battery status is displayed as follows by the three LEDs of
the battery level indication(27):
LED colour Meaning
Green – Orange – Red maximum charge / power
Orange – Red medium charge / power
Red weak charge – Recharge the
battery.
1. Press on the battery icon(29) on the battery(16).
ðYou can read the battery status from the battery level
indication(27).
27 29
Exchanging the valve adapter (cordless compressor)
Depending on the field of application, the following valve
adapters can be connected either directly to the device or via
the optional compressed-air hose(18).
No. Designation Description
21 Presta valve adapter To be used with Presta valves
22 Dunlop valve adapter To be used with Dunlop valves
23 Ball needle To be used with footballs or
the like
24 Universal adapter, short To be used with air mattresses
or the like
25 Universal adapter, long To be used with air mattresses
or the like
Info
We recommend using the cordless compressor with
connected compressed-air hose.
1. Unscrew the union nut(9).
9
31
20
30
2. Insert either the (optional) compressed-air hose(20) with
its connector side(31) or the valve
adapter(21, 22, 23, 24, 25) by rotating it clockwise.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Trotec Compressore
Manuali Compressore popolari di altre marche

Emerson
Emerson Copeland Scroll Digital HLR Series Manuale di istruzioni

Drawmer
Drawmer 1968 MKII Manuale utente

Badger Air-Brush
Badger Air-Brush X-Air 80-8 Manuale di istruzioni

Omnitronic
Omnitronic CL-166 Manuale utente

Scheppach
Scheppach HC24V Istruzioni per il montaggio

Ingersoll-Rand
Ingersoll-Rand centac C950 Manuale tecnico












