1. Important Safety Instructions --------------------------------------- p. 4
1.1 General
1.2 Symbols & Messages
1.3 Safety Instructions
1.3.1 Transportation
1.3.2 Ambient Conditions
1.3.3 Installation
1.3.4 Operation
1.3.5 Service & Maintenance
1.3.6 Storage
2. Get Acquainted with the C³V ----------------------------------------- p. 7
2.1 Front Panel Overview
2.2 Models & Output Ratings
3. Operation ------------------------------------------------------------------- p. 9
3.1 General
3.2 Description
3.3 Output (Reading) Mode & Setting Mode
3.4 Switching between Two Modes
4. Keys: Special Functions --------------------------------------------- p. 12
4.1 Normal Operations
4.2 Special Functions
4.3 Default Output State
5. C³V Series Communication Interfaces --------------------------- p. 14
5.1 Communication Data Rate
5.2 C³V Series with RS232 Interface
5.2.1 RS232 Connection to PC
5.3 C³V Series with USB Interface
5.4 C³V Series with RS485 Interface
5.4.1 RS485 Termination Resistor Installation & Wiring
5.4.2 RS485 Address Settings

P.3
6. C³V Series Communication Protocol ----------------------------- p. 17
6.1 Communication between PC and C³V Series
6.2 Message Terminator of Protocol: CR LF
6.3 Data Format (PC to C³V Series)
6.3.1 ADDR (PC to C³V Series)
7. Automatic Fan Speed vs Temperature Control --------------- p. 23
7.1 PWM Fan Speed Control
7.2 Over Temperature Protection (OTP) Alarm
8. C³V Series Wiring and Connections ------------------------------- p. 24
8.1 All Connections
8.2 Special Connector to Prepare
8.3 Wire Size Table
8.4 Type of Panel Layouts
9. Mounting and Ventilation -------------------------------------------- p. 27
9.1 Flat Mount
9.2 Erect Mount
10. C³V Series Specifications ------------------------------------------- p. 29
11. Appendix ------------------------------------------------------------------ p. 31

P.4
1. Important Safety Instructions
1.1 General
This chapter contains important safety instructions for fully utilizing the C3V Series DC
Power Supply. It is important that this manual is read and understood by all persons
prior to transporting, installing, operating, servicing, or maintaining the product.
1.2 Symbols & Messages
The following symbols mainly appear in this chapter and may be found in other
chapters and on the product itself.
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury
Indicates a potentially hazardous situation which, if not
avoided, may result in death or serious injury
Indicates a potentially hazardous situation which, if not
avoided, may result in moderate or minor injury
Electrical shock risk
Fire risk
Attention
EMI risk
High temperature
Condensation
Earth terminal
1.3 Safety Instructions
1.3.1 Transportation
When transporting the product, please ensure that the original packaging is used to
prevent damage to the product.

P.5
1.3.2 Ambient Conditions
The product is designed for indoor use.
Condensation may occur after the product was shipped, or
subject to a sudden change in an atmosphere of temperature or
humidity. Do not use the product for at least two hours to
ensure it is dry before turning it on.
Do not place the product in high humidity area.
Do not expose the product to direct sunlight or any heat source.
Do not block the ventilation openings at the enclosure of the
product.
Do not place any heavy objects on the product.
1.3.3 Installation
The product is constructed to Protection Class I. Connect the product
to an earthed wall receptacle with a power cord approved by relevant
International Standards.
The product is rated at AC input 85~264V, 47~63Hz mains.
1.3.4 Operation
Be careful! A change from open circuit to short circuit could result in
high current sparks and cause injury to eyes. An instantaneous
power circuit change from short to open may induce high voltage and
arcing, causing shock and injury to eyes.

P.6
1.3.5 Service & Maintenance
The product operates at hazardous high voltage (near DC 380V or
AC 267V). Only qualified personnel can carry out servicing or
maintenance.
Always use a properly rated voltage sensing device to confirm that all
power is off.
Before attempting any service, disconnect the product from all power
supply and ensure that no harmful residual voltage remains at the
terminals of bulk capacitors.
Replace the fuse only with the same amperage and voltage ratings
to avoid risk of fire.
This is a Class A device which may cause RF interference
within the home.
The product should only be operated when the case is securely
closed, with all screwed tightened.
While operating the product, the wearing of metal or other
conducting jewelry such as chains, bracelets, rings, etc. is not
recommended.
1.3.6. Storage
Location: Indoor
Relative Humidity: <80%
Temperature: -10℃ ~ 70 ℃

P.7
2. Get Acquainted with C³V Series
2.1 Front Panel Overview
Panel display:
1 Display Meter
4-digit meter displays voltage, current and internal
temperature of the product.
For auxiliary uses of system parameters setup.
2 Output key Turns the output on/off.
3 Enter key Circulatory mode selection. Up/Down inputs confirmation.
4 Up key Input increments.
5 Down key Input decrements.
6 V-LED
Green “V” denotes unit = ”VOLT” for meter display.
Lit state: Meter display in Output (Reading) mode.
Blinking: Meter display in Setting mode.
7 A-LED
Orange “A” denotes unit = ”AMPERE” for meter
display.
Lit state: Meter display in Output (Reading) mode.
Blinking: Meter display in Setting mode.
8 cc-LED
Red “cc” symbol.
Off state: Output in constant voltage (CV) mode.
Lit state: Output in constant current (CC) mode.

P.8
9 Output LED
Green “ON” symbol.
Off: Output Off.
Lit: Output On.
10 Output terminals Ground terminal, negative terminal, and positive
terminal, respectively.
11 Model & output
ratings See 2.2
2.2 Models & Output Ratings
C³V series consists of 3 models and ratings as listed below:
Model 2010 4005 6003
Voltage 0 - 20V 0 - 40V 0 - 60V
Current 0 - 10A 0 - 5A 0 - 3.5A
Power 200W 200W 210W

P.9
3. Operation
3.1 General
C³V Series integrates two power supplies – constant voltage (CV) and constant
current (CC). These two power supplies exclusively operate, and outputs do not
exceed user-preset limit. CV or CC states are dependent on and limited by the
comparison between load conditions and C³V Series settings.
3.2 Description
C³V Series utilizes the Up and Down keys to set desired voltage and current outputs.
Real time voltage and current are displayed on the Display Meter. Pressing the Enter
key momentarily switches between different operation modes.
The V-LED and A-LED indicate the selected operation mode. The CC-LED indicates
that the power supply currently being in CC Output (Reading) mode.
3.3 Output (Reading) Mode & Setting mode
Output (Reading) Mode
Upon AC powering on the C³V Series, the unit automatically enters “Output (Reading)
Mode” and the green V-LED illuminates. The values shown on the Display Meter refer
to the last used data. Pressing the Enter key momentarily, you can read the voltage,
current (if a load was connected) and internal temperature. The outputs are controlled
by preset CC and CV values, as shown in the graph below.

P.10
Setting Mode
By pressing the Enter key for 3 seconds, you will hear a short beeping sound. This
indicates that the C³V Series has entered “Setting Mode”. “The V-LED OR A-LED
“ AND “ the respective decimal point ” will be blinking on the 4-digit Display Meter.
Use the Up or Down keys to set the desired voltage or current. Press the Enter key for
3 seconds to confirm. The C³V Series now reverts to “Output (Reading) Mode”. The
adjusted value is displayed in the graph below.