Tyler N5D Manuale

Installation & Service
Manual
N5D, N5DH, N5DL, N5DSC
This manual has been designed to be used in conjunction with the
General (UL/NSF) Installation Service Manual.
Save the Instructions in Both Manuals for Future Reference!!
This merchandiser conforms to the American National Standard Institute & NSF International Health and Sanitation standard ANSI/NSF 7 - 2003.
RINTED IN Specifications subject to RE LACES ISSUE ART
IN U.S.A. change without notice. EDITION 10/05 DATE 5/06 NO. 9037155 REV. D
Tyler Refrigeration * Niles, Michigan 49120
NARROW MULTI-DECK DAIRY/DELI MERCHANDISERS
Medium Temperature Refrigerated Display Cases

CONTENTS
N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 2 May, 2004
Page
Specifications
N5D/N5DH/N5DL Specification Sheets . . . . . . . . . . . . . . . . . . . . . . . 4
N5DSC Specification Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Pre-Installation Responsibilities . . . . . (See General-UL/NSF I&S Manual)
Installation Procedures
Carpentry Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Case ull-Up Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Electrical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Plumbing Procedures . . . . . . . . (See General-UL/NSF I&S Manual)
Refrigeration Procedures . . . . . (See General-UL/NSF I&S Manual)
Defrost Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Defrost Control Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation Procedure Check Lists (See Gen.-UL/NSF I&S Manual)
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
N5D/N5DH/N5DL Domestic & Export (50Hz) 4’ Case Circuits . . . . . 9
N5D/N5DH/N5DL Domestic & Export (50Hz) 6’ Case Circuits . . . . 10
N5D/N5DH/N5DL Domestic & Export (50Hz) 8’ Case Circuits . . . . 11
N5DSC Domestic & Export (50Hz) 4’ and 6’ Case Circuits . . . . . . 12
Canopy Lighting Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Optional Shelf Light Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Cleaning and Sanitation . . . . . . . . . . . . (See General-UL/NSF I&S Manual)
Component Removal and Installation Instructions for Cleaning 15
Mirrors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Shelves and Shelf Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Bottom Trays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Front Air Ducts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Rear Duct anels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Discharge Air Honeycomb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Top Duct . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Lower Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Upper Cladding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Installation & Service Manual N5D, N5DH, N5DL, N5DSC
November, 2005 Page 3
Page
General Information
NSF Product Thermometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Service Instructions
Preventive Maintenance . . . . . . (See General-UL/NSF I&S Manual)
Troubleshooting Self-Contained Units . . . . . . . . . . . . . . . . . . . . . 17
Light Servicing
Ballast and Lighting Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Fan Blade and Motor Replacement (See Gen.-UL/NSF I&S Manual)
Color Band and Bumper Replacement (See Gen.-UL/NSF I&S Man.)
Parts Information
Operational Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Cladding and Optional Trim Parts List . . . . . . . . . . . . . . . . . . . . . 20
TYLER Warranty . . . . . . . . . . . . . . . . . (See General-UL/NSF I&S Manual)
The following Narrow Medium Temperature Dairy and Deli Merchandiser models are covered
in this manual:
MODELS DESCRIPTION
N5D 3’, 4’, 6’ 8’ REMOTE MULTI-DECK DAIRY/DELI MERCHANDISER
N5DH 4’, 6’ 8’ REMOTE DEEP WELL MULTI-DECK
DAIRY/DELI MERCHANDISER
N5DL 4’, 6’ 8’ REMOTE LOW FRONT MULTI-DECK
DAIRY/DELI MERCHANDISER
N5DSC 4’ 6’ SELF-CONTAINED MULTI-DECK DAIRY/DELI MERCHANDISER

N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 4 December, 2006
SPECIFICATIONS
N5D/N5DH/N5DL Narrow Multi-Deck Dairy/Deli Merchandisers

Installation & Service Manual N5D, N5DH, N5DL, N5DSC
Page 5November, 2005

N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 6 December, 2006
N5DSC Narrow Multi-Deck Dairy/Deli Merchandisers (Self-Contained)

Installation & Service Manual N5D, N5DH, N5DL, N5DSC
May, 2006 Page 7

N5D, N5DH, N5DL, N5DSC Tyler Refrigeration
Page 8 May, 2004
INSTALLATION PROCEDURES
Carpentry Procedures
Case Pull-Up Locations
The N5D, N5DH, N5DL and N5DSC models
have four pull-ups at each end of the case.
ull-ups A, B, C and D are located as shown
and should be install-ed and tightened starting
with A and finishing with D.
See “General-UL/NSF I S Manual” for line-
up assembly instructions.
Electrical Procedures
Electrical Considerations
CAUTION
Make sure all electrical connections at com-
ponents and terminal blocks are tight.
NOTE
Since the lower front cladding is shipped
loose, the wiring has immediate access.
Case Fan Circuit
This circuit is to be supplied by an uninter-
rupted, protected 120V circuit. The case fan
circuit is not cycled during defrost on any of
these models.
Fluorescent Lamp Circuit
N5D/N5DH/N5DL/N5DSC case lighting is
supplied by 800MA HO horizontal lights. It
is controlled by a light switch in each case.
The standard lighting is 1-row of high output
800MA canopy lights. N5D/N5DH/N5DL/
N5DSC also offers up to 4 rows of T-8 shelf
lights with remote electronic ballasts.
Self-Contained Circuit
N5DSC cases are self-contained units.
Specific information on self-contained units,
not listed on the specifications sheets on
pages 6 and 7, should be obtained directly
from TYLER Refrigeration.
Defrost Information
See “General-UL/NSF I S Manual” for
operational descriptions for Off Time
defrost control.
Defrost Control Chart
Defrost
Defrost Defrosts Duration Term.
Type Per Day (Min) Temp.
N5D(H/L)
Off Time 4 24 -----
N5DSC
Off Time 6 28 -----
WIRING DIAGRAMS
ELECTRICIAN NOTE - OVERCURRENT
PROTECTION
120V circuits should be protected by 15 or 20 Amp
devices per the requirements noted on the cabinet
nameplate or the National Electrical Code, Canadian
Electrical Code - Part 1, Section 28. 208V defrost
circuits employ No. 12 AWG field wire leads for field
connections. On remote cases intended for end to
end line-ups, bonding for ground may rely upon the
pull-up bolts.
The following wiring diagrams on pages 9
thru 14 will cover the N5D, N5DH, N5DL and
N5DSC case circuits and the lighting
circuits.

May, 2004 Page 9

Page 10 May, 2004
Questo manuale è adatto per i seguenti modelli
4
Altri manuali Tyler Merchandiser
Manuali Merchandiser popolari di altre marche

True
True GDIM-26 Manuale utente

Structural Concepts
Structural Concepts Oasis Mobile Series Istruzioni per l'installazione

Hussmann
Hussmann Q2-SS Istruzioni operative originali

Haussmann
Haussmann RL Manuale utente

Howard McCray
Howard McCray R-CDS32E-4 Manuale utente

Hussmann
Hussmann microSC SHM-A Series Manuale utente