Important Notes
- 1 -
This section contains important information to ensure the user’s safety and prevent potential damaged to
property. Please read this section carefully and use the product accordingly.
●
Don't install the product in the place where the gap between the door and the frame is 3/16’’ (5mm) or more.
●
Make sure that no unauthorized person has access to the password.
●
Do not operate the product with wet hands, and keep liquids such as water or drinks away from the product,
or the product may malfunction or be damaged.
●
Do not use excessive force or sharp objects to turn the handle, as this can damage the product.
●
Make sure that the door is completely closed when going outside. The manufacturer does not assume the
responsibility for any harm caused by engagement of the lock on an improperly closed door.
●
Be sure to correctly match the poles (+/-) when installing the batteries. Install the batteries with the correct
poles (+/-).
●
Do not use water, benzene or alcohol when cleaning the product, as these fluids can cause product
malfunction.
●
Replace the batteries after the battery replacement alarm sounds.
●
According to the wireless communication environment, its battery may drain faster.
●
You must use AA Alkaline Battery and not use Lithium Battery or Rechargeable Battery.
Ultraloq Terms & Policies
Before using all Ultraloq products, please read all applicable terms, rules, policies and
usage provisions found at www.u-tec.com/company/privacy. By using your Ultraloq,
you agree to be bound by the U-tec Privacy Policy.
Need Help?
For technical documents and more information, please visit www.u-tec.com/support
Email: [email protected]

Packing List
- 2 -
ENGLISH
Interior Assembly Exterior Assembly Interior Assembly Mounting Plate Mortise
Ultraloq UL300
Fingerprint and Touchscreen Smart Lock
User Guide (V1.1)
User Guide
Spring
Screw DScrew A Screw C
Reset Needle
Backup Key
A
Spindle
B C
Screw B
B1 B2 B3
AA Alkaline Batteries
(May not be included
for some regions)
Bridge
(Optional)
Drill Template
2”
(50mm)
4”
(100mm)
UL300 Drill Template
V1.3
Fold
Centerline
Centerline
Centerline
Centerline
Centerline
Centerline
DOTTEDLINE MUST BE PLACED ON DOOR EDGE
MORTISEDEPTH
HorizontalCenter Line
Around3 feet(1 meter)
abovethe ground
UpUp
1”
(25mm)
1”
(25mm)
1
”
(25mm)
1
”
(25mm)
Backset
EDGEOF DOOR
StudScrew/ConnectionCable Hole
Spindle/HandleHole
ExtraSpindle Hole
StudScrew Hole
Centerline
9
/
16”
(15mm)
23
/
8”
(60mm)
91
/
2”
(240mm)
813/
16”
(224mm)
87/
16”
(212mm)
13/
8”
(35mm)
57/
16”
(138mm)
9
/
16”
(15mm)
9
/
16”
(14mm)

1. Door Dimensions
Installation Guide
- 3 -
Installation Video
Please scan this QR code to watch the easy step by step installation video before attempting to install
Ultraloq UL300. Or you can also view www.u-tec.com/lock/Ul300/guide directly.
If you have a new door,
please drill the holes
according to according to
the Drill Template.
Step 1
Measure to confirm that the door is
between 1-9/16'' to 4'' (40mm to 100mm)
Step 2
Measure to confirm that the
backset is 4’’ (100mm)
Step 3
Measure to confirm the other dimensions.
2”
(50mm)
4”
(100mm)
Fold
Centerline
Centerline
Centerline
Centerline
Centerline
Centerline
DOTTED LINE MUST BE PLACED ON DOOR EDGE
MORTISE DEPTH
Horizontal Center Line
Around 3 feet(1 meter)
above the ground
UpUp
1”
(25mm)
1
”
(25mm)
1
”
(25mm)
1
”
(25mm)
Backset
EDGE OF DOOR
Stud Screw
Connection Cable Hole
Spindle/Handle Hole
Extra Spindle Hole
Stud Screw Hole
Centerline
9
/
16”
(15mm)
9
/
16”
(15mm)
23
/
8”
(60mm)
91
/
2”
(240mm)
13/
8”
(35mm)
81 3/
16”
(224mm)
87/
16”
(212mm)
57/
16”
(138mm)
9
/
16”
(14mm)

2. Installing Mortise and Strike
- 4 -
2.1 Mortise Overview
Direction Switch: Used to Mortise Handing.
Latch: Used to lock and unlock.
Bolt: Used to lock and unlock for securer.
Spindle Hole: The spindle goes through this hole to drag Latch and Bolt.
Extra Bolt: Used for double locked.
Extra Spindle Hole: The cylinder tailpiece goes through this hole to drag Extra Bolt.
Latch
Bolt
Extra Bolt
Direction Switch
Spindle Hole
Extra Spindle Hole
ENGLISH

- 5 -
2. 2 Mortise Handing
Please make sure the inclined corner is facing the frame. If the Mortise is in the correct handing for the
door, you may skip the next section on Reversing the Mortise Handing.
Step 1. keep the Direction Direction Switch to the top all the way.
2.3 Reversing the Mortise Handing
Step 2. Push and hold the Latch into the Mortise entirely.
Step 3. While the Latch is inside the Mortise, rotate the Latch 180
o
.
Step 4. Release the Latch and it will come out of the Mortise.
Tip: When you release the Latch, please unstuck the small bolt from the side plate of the Mortise.
Step5. Release the Direction Switch to default location.

- 6 -
Keep the Bolt and Extra Bolt retracted (unlocked status), then insert the Mortise and tighten 4 Screws A.
2.5 Installing Strike
Attach the Strike to the jamb using 4 Screws A.
2.4 Installing Mortise
Note:
●
The Mortise position should be Latch on top and Bolt in the Bottom.
●
The inclined corner of the Latch must be facing towards the Strike in the door's frame.
●
Check the door holes dimensions and assure the Mortise fits. If it doesn't, please adjust the holes sizes.
Don't add hand pressure.
ENGLISH

- 7 -
3.1 Adjust the handle direction of the Exterior Assembly
Step 1.
Loose the screw inside the hole. Please don’t take the screw out during the operation.
Step 2.
Take out the handle and adjust it to the correct direction.
Step 3.
Tighten the screw to fix the handle.
3. Installing Exterior Assembly

- 8 -
3.2 Installing Exterior Assembly
Step 1.
Insert the spindle into the Exterior Assembly’s hole.
If the thickness of the door is between 1-9/16'' to 2-3/8'' (40mm to 60mm), please use Spindle A (3-1/8'', 80mm).
If the thickness of the door is between 2-3/8'' to 3-1/8'' (60mm to 80mm), please use Spindle B (4'',100mm).
If the thickness of the door is between 3-1/8'' to 4'' (80mm to 100mm), please use Spindle C (4-3/4'', 120mm).
Step 2.
Adjust the arrow pointing to the handle.
Note: This step is very important, otherwise UL300 handle can’t work correctly.
Step 3.
Pass the cable above the Mortise.
Step 4.
Insert two screw into the holes, and pass the Spindle through the Spindle hole of the Mortise.
Attach the Exterior Assembly on the door.
Note:
Before installing the Interior Assembly Mounting Plate, please keep steady the Exterior Assembly.
Be sure not to move it.
ENGLISH

- 9 -
Step 1.
Route the cable through the hole on Interior Assembly Mounting Plate.
Step 2.
Attach the Interior Assembly Mounting Plate on the door and tighten two Screws B.
If the thickness of the door is between 1-9/16'' to 2-3/8'' (40mm to 60mm), please use Screw B1.
If the thickness of the door is between 2-3/8'' to 3-1/8'' (60mm to 80mm), please use Screw B2.
If the thickness of the door is between 3-1/8'' to 4'' (80mm to 100mm), please use Screw B3.
Note:
1. The screw bolts of the Mounting Plate must face the installer.
2. Before tightening the screws completely, tighten one screw up to the middle, then, start with the second one,
this way you will have the right installation. After you have both screws up to the middle you can proceed and
tighten them completely.
Step 1.
Adjust the handle direction of the Exterior Assembly. The operation is the same with the exterior handle.
Step 2.
After confirming the Extra Bolt is retracted, rotate the Extra Bolt Knob to Unlock. The knob and the cylinder
tailpiece should be all vertical.
4. Installing in the interior Mounting Plate
5. Installing Interior Assembly
Indice
Lingue:
Altri manuali U-tec Serratura

U-tec
U-tec Ultraloq UL3 Manuale utente

U-tec
U-tec Ultraloq UL3 Manuale utente

U-tec
U-tec Ultraloq U-Bolt Pro Manuale utente

U-tec
U-tec UltraloqUL3 Manuale utente

U-tec
U-tec Ultraloq UL1 Manuale operativo

U-tec
U-tec Ultraloq UL3 Manuale utente

U-tec
U-tec Ultraloq UL3 Manuale utente

U-tec
U-tec Ultraloq UL3 Manuale utente

U-tec
U-tec Ultraloq U-Bolt Pro Manuale utente

U-tec
U-tec Ultraloq LATCH 5 FINGERPRINT Manuale utente