UeeVii CPE450 Manuale utente

Outdoor CPE
Model: CPE450
--Quick Installation Guide--
Note:
A. Thank you for order and using our product, please read the manual carefully
before use. If there are any problems during the use, please contact us in time;
B.The installation of this device requires some network knowledge. If you can't
install it, please let us know or contact a professional.
Tech Service Email: support@tomlov.com

Contents
1. Get Started to Know Your Wireless Bridge
2. CPE Bridge For Video Transmission Introduction
3.Outdoor CPE Function
4.Outdoor CPE Specification
5. Connection Diagram
6. Digital Display Wireless Bridge Set Up
7. How to Access and Setting the CPE Via PC
8.Bridge Configuration (WEB UI)
9. Field Applications
10.Wireless Surveillance Connection for Elevator Well
11.Tips
01
01
02
02
03
04-05
06-07
09-10
11-12
13
14

1. Get Started to Know Your Wireless Bridge:
01
Package Included
2 x Outdoor Wireless Bridge
2 x PoE Adapter
2 x Metal Cable Tie
1 X User Manual
Note: This wireless bridge is
powered by a PoE adapter
through a network cable, so does
not require a DC power supply.
The DC power adapter and cable
are not included in the package.

3.Outdoor CPE Function:
2. CPE Bridge For Video Transmission Introduction:
CPE is widely used in highways, reservoir river monitoring, elevator monitoring
systems, site crane monitoring systems, port terminal monitoring systems,
marine aquaculture monitoring systems and so on.
CPE Video Bridge Transmission usually consists of two devices in AP and
Client mode respectively. At the Client-side (Receiving side) CPE connects with
IP Camera, at the AP side (Transmitting side) CPE connects with a video
recorder. The AP can be receiving wireless data transmitted from multiple
Clients, and it is easy and convenient for centralized management of the
remote equipment.
1. Long-distance 5.8G wireless transmission equipment
2.Support point-to-point, point-to-multipoint mode
3.Transmission distance up to 3km(Barrier-Free)
4.WDS networking mode, video network dual compatible.
5. Dialing to set the transmitter and receiver, and also support the PC to modify
the IP settings.
6.Dynamic MIMO power saving mode (DMPS) and automatic power-saving
transmission (APSD)
In addition to helping you in remote monitoring, wireless bridges can also help
you extend the network signal to warehouses, barns, garages, and other
buildings near your home.
02

4.Outdoor CPE Specification:
5. Connection Diagram:
5.1 . Transmitting Side:
Master control:AR9344
DRAM:DDR2 64MByte
FLASH:8MByte
Wired Interface:10/100Mbps LAN*2
CPE Transmission rate: 300Mbps (not network rate)
Transfer method: Direct Sequence Spread Spectrum (DSSS)
Modulation: OFDM/BPSK/QPSK/CCK/DQPSK/DBPSK
Network Standard:IEEE802.11n,IEEE802.11a ,IEEE802.3u
Supporting agreement: CSMA/CA TCP/IP,IPX/SPX,NetBEUI,DHCP,NDIS3,N-
DIS4,NDIS5
Frequency Range: 4900~6100MHz
Power consumption: ≤3W
Power scheme: POE 24V 1A
Antenna gain: 14DBi
Management settings:WEP management,Telnet,Serial
Encryption:WEP encryption 64/128bits, WPA, WPA2, 802.1x
Operating temperature:-30℃~65℃
03
Model: CPE450

6. Digital Display Wireless Bridge Set Up:
6.1 Connection Diagram:
5.2. Receiving Side:
The digital display bridge is simply connected by dialing. After setting Bridge 1
and Bridge 2 to A and B mode, set the two bridges to the same number(1,2,3
,...,F)through the “reset” button, then the two bridges can be automatically
connected without using a computer for IP setting. The dialing settings are only
connected using a point-to-point bridge, which is not suitable for point-to-multi-
point connections.
04
*It is strongly recommended to pair the wireless bridge in this way.

6.2
Before connecting the power supply, move the bridge 1 to the A end through
the A-B button, and the bridge 2 moves to the B end through the A-B button,
the A end represents the receiving mode, the B end represents the transmitting
mode; The bridge 1 and the bridge 2 are respectively set after A and B.
Connect the bridge to the power supply, the digital display shows “L” and
flashes, and the “L” disappears to indicate that the configuration connection is
successful.
6.4 LED Indication Chart:
6.3
The reset button to set the led digital display, click once the startup configura-
tion status, continue to click, the number will increase, can be continuously
increased.
Assume that a pair of bridges with a number of 3 is configured After bridge 1
set to 3, after the bridge 2 set to 3, first the LED light will flash, then "L" flashes
to indicate the application is being configuration, please be patient, When "L"
flashes, it will become the number "3", and the number "3" will continue to flash
until the bridge 1, bridge 2 is connected after the success, the LED display “3”
is always on, not flashing, indicating that the bridge 1 and bridge 2 has been
successfully networked.
WLAN
LAN1/LAN2
PWR
LED
LED
LED
Point Light
RST
RST
After the bridge is connected successfully, the WLAN light will be on,
not connected the WLAN light will not be lit.
The data connection is successful, the LED light is on, otherwise, it
is not bright.
Power indicator, the LED is on after the power is connected
Digital display LED display "H" indicates manual configuration status
Digital display LED display "L" and flashing indicates settings status
Digital display LED flashing indicates edit the config or conne cting
A, B status lights, lighting is B mode, no lighting is A mode.
Click once, the LED display number increases, looping from 0, 1, ..., F.
Press over 10s, release the "reset" button, the system automatically
restarts
05

7. How to Access and Setting the CPE Via PC
6.5 LED Number & IP Chart:
LED A IP B IP 2.4G ID 5.8G ID
0 192.168.255.100 192.168.255.200 0
1 192.168.255.101 192.168.255.201 1
0
2 192.168.255.102 192.168.255.202 2
165
3 192.168.255.103 192.168.255.203 3
161
4 192.168.255.104 192.168.255.204 4
157
5 192.168.255.105 192.168.255.205 5
153
6 192.168.255.106 192.168.255.206 6
149
7 192.168.255.107 192.168.255.207 7
48
8 192.168.255.108 192.168.255.208 8
44
9192.168.255.109 192.168.255.209 9
40
a 192.168.255.110 192.168.255.210 10
36
b 192.168.255.111 192.168.255.211 11
140
c 192.168.255.112 192.168.255.212 13
132
d 192.168.255.113 192.168.255.213 96
124
e 192.168.255.114 192.168.255.214 50
116
f 192.168.255.115 192.168.255.215 55
108
100
Step 1. Use a PoE adapter to power the wireless bridge through a network
cable. Pay attention to the "PoE" and "LAN" ports marked on the PoE adapter,
and power is supplied by POE instead of a DC power interface.
Step 2. Use a network cable to connect the CPE "LAN" port, connect the
network cable other ends to the PoE Adapter "POE" port, use another network
cable to connect to the "LAN" port of the PoE adapter, and connect the other
end of the network cable to the computer's "LAN" port.
Step Description:
06

Step 3. Find the number of the Wireless Bridge CPE digital display tube. For
example, the number is 1 and the CEP is the A master bridge, then the IP of
this CPE is 192.168.255.101; if the CPE is the B slave bridge, then the IP
address of the CPE is 192.168.255.201.(There is a table corresponding to a
number and IP in the manual)
Step 4. Very important step: Modify your computer's IP address, change your
computer's IP address to 192.168.255.xxx(192.168.255.xxx cannot be the
same as the IP of the CPE), make your computer's IP and the bridge's IP
address be on the same network segment so that you can access them.
Please refer to the manual to modify the computer IP address step or Google
searches how to modify the computer IP address, it is very simple.
Step 5. After you modify your computer's IP address, you open the computer
browser and enter the IP address of the wireless bridge to access. For exam-
ple, enter 192.168.255.101 to access.
Step 6. Enter the account password "admin/admin" to access, and set after
successful access.
7.1 How to Configure Your PC IP As 192.168.255.xxx:
a. Find the network icon in the lower right corner and click Open Network
and Internet Settings.
07

c. Find the network connection you are using and right click on Properties.
b. Select Ethernet and Click the Change Adapter Option.
d. Double-click the IPV4 setting,
select the IP address below,
enter the IP and confirm.
e. Configure your PC IP as
192.168.255.xxx (xxx is a figure
2-254), note that the set PC IP cannot
be the same as the IP of the CPE.
08
255
255
Indice
Altri manuali UeeVii Hardware di rete
Manuali Hardware di rete popolari di altre marche

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manuale utente

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manuale utente

Yudor
Yudor YDS-16 Manuale utente

D-Link
D-Link ShareCenter DNS-320L Manuale utente

Samsung
Samsung ES1642dc Istruzioni per l’uso

Honeywell Home
Honeywell Home LTEM-PV Istruzioni per il montaggio