Unitron 9646 Manuale utente

UserManual
Wideband to Quattro convertor
9646

Wideband to Quattro convertor (Ref. 9646) v1.0
2
CONTENTS
1.
I
NSTALLATION OF THE HARDWARE
...................................................... 3
2.
U
SE OF THE MODULE
........................................................................ 3
3.
T
ECHNICAL
S
PECIFICATIONS
............................................................. 4
4.
S
AFETY
I
NSTRUCTIONS
.................................................................... 5
5.
C
ONDITIONS OF WARRANTY
............................................................... 6
No part of this manual may be copied, reproduced, transmitted, transcribed or translated into any language
without permission.
Unitron reserves the right to change the specifications of the hardware and software described in these manuals
at any time.
Unitron cannot be held liable for any damages resulting from the use of this product. Specifications
are subject to change without notice. 10/16
©Unitron - Frankrijklaan 27 - B-8970 Poperinge - Belgium
T+32 57 33 33 63 F+32 57 33 45 24
email sales@johansson.be
www.johansson.be - www.unitrongroup.com

Wideband to Quattro convertor (Ref. 9646) v1.0
3
1.
INSTALLATION OF THE HARDWARE
2.
USE OF THE MODULE
This Wideband to Quattro convertor allows you to make a hybrid installation where classic 4-
wire applications (with Quattro or quad LNBs) coexist with new 2-wire wideband applications.
When upgrading your classic Quattro or Quad LNB to a wideband LNB, which will support the
newest multi-tuner STBs, the 9646 enables you to keep using the classic STBs.
Basically, the 9646 converts both wideband polarities (V & H / 290-2340MHz) back into the
standard 4 polarities (VL, HL, VH, HH / 950-2150MHz).
The 9646 can be connected directly to the wideband LNB or further down the trunks, by using
for instance a wideband tap (Johansson ref. 9656).

Wideband to Quattro convertor (Ref. 9646) v1.0
4
Important : DC must be provided on VL to power the 9646 and the wideband LNB (DC power
pass from VL to V).
3.
TECHNICAL SPECIFICATIONS
9646
Inputs - 2
Outputs - 4
Input frequency (MHz) MHz 290 – 2340
Output frequency (MHz) MHz 950 - 2150
Input/output connectors Ohm 75 (F type Female)
Output level dBµV 55 to 80
Input level dBµV 54 to 79
Conversion gain dB 0 to 5
Isolation dB 26
Return loss dB >=8 (Typ 12)
Band and polarity -
V : Vertical 290-2340MHz input
H : Horizontal 290-2340MHz input
VL : Vertical low-band 950-1950MHz output
HL : Horizontal low-band 950-1950MHz output
VH : Vertical hi-band 1100-2150MHz output
HH : Horizontal hi-band 1100-2150MHz output
DC input voltage V 10 – 20
Max DC current consumption mA < 150 @ 20 Volt
Power supply - From STB or multiswitch (VL)
Dimensions mm 90x80x40

Wideband to Quattro convertor (Ref. 9646) v1.0
5
4.
SAFETY INSTRUCTIONS
Read these instructions carefully before connecting the unit
To prevent fire, short circuit or shock
hazard:
Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
To avoid any risk of
overheating
:
Install the unit in a well aery location and keep a minimum distance of 15 cm around the
apparatus for sufficient ventilation
Do not place any items such as newspapers, table-cloths, curtains,
on the unit that might cover the ventilation holes.
Do not place any naked flame sources, such as lighted candles, on the apparatus
Do not install the product in a dusty place
Use the apparatus only in moderate climates (not in tropical climates)
Respect the minimum and maximum temperature specifications
To avoid any risk of electrical
shocks
:
Connect apparatus only to socket with protective earth connection.
The mains plug shall remain readily operable
Pull out power plug to make the different connections of cables
To avoid electrical shock, do not open the housing of adapter.
Maintenance
Only use a dry soft cloth to clean the
cabinet.
Do not use solvent
For repairing and servicing refer to qualified
personnel.
Dispose according your local authority’s recycling processes

Wideband to Quattro convertor (Ref. 9646) v1.0
6
5.
CONDITIONS OF WARRANTY
Unitron N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production indicated on
it. See note below.
If during this period of warranty the product proves defective, under normal use, due to
defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace the
product. Return the product to your local dealer for reparation
THE WARRANTY IS APPLIED ONLY FOR DEFECTS IN MATERIAL AND WORKMANSHIP
AND DOES NOT COVER DAMAGE RESULTING FROM:
Misuse or use of the product out of its specifications.
Installation or use in a manner inconsistent with the technical or safety standards in
force in the country where the product is used
Use of non-suitable accessories (power supply, adapters...).
Installation in a defect system.
External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
Production date or serial number on the product is illegible, altered, deleted or
removed.
The product has been opened or repaired by a non-authorized person.
NOTE
Date of production is YYWW format, example 1447 = year 2014 – week 47.
For the serial number barcodes, the date corresponds to the 4 first numbers
UNITRON NV
Frankrijklaan 27
B-8970 Poperinge
Belgium
T +32 57 33 33 63
F +32 57 33 45 24
sales@johansson.be
www.johansson.be
Indice
Altri manuali Unitron Convertitore multimediale

















