Universal Remote Control TRF-ZW2 Manuale utente

i
TRF- W2
Z-Wave Gateway
Owner’s Manual
®

Congratulations on your choice!
TRF-Z 2 Owner's Manual © 2015 Universal Remote Control, Inc.
The information in this manual is copyright protected. No part of this manual may be
copied or reproduced in any form without prior written consent from Universal
Remote Control, Inc.
UNIVERSAL REMOTE CONTROL, INC. SHALL NOT BE LIABLE FOR OPERATIONAL,
TECHNICAL OR EDITORIAL ERRORS/OMISSIONS MADE IN THIS MANUAL.
The information in this manual may be subject to change without prior notice.
URC - Control the Experience is a registered trademark of Universal Remote Control, Inc.
Total Control is a registered trademark of Universal Remote Control, Inc.
All other brand or product names are trademarks or registered trademarks of their
respective companies or organizations.

Table of Contents
READ ME FIRST 1
CONGRATULATIONS 2
FEATURES AND BENEFITS 2
PACKAGE CONTENTS 3
DEVICE LAYOUT 4
INSTALLATION 6
USING THE TRF-ZW2 7
RESTRICT INSTALLER OFFSITE ACCESS 8
HARDWARE SPECIFICATION 9
LIMITED WARRANTY STATEMENT 10
END USER AGREEMENT 12
FEDERAL COMMUNICATIONS COMMISSION COMPLIANCE STATEMENT 13

1
ead Me First
• Please read this manual before using the device to ensure safe and proper use.
• If you have difficulty installing this product, or require more information, please contact U C Technical Support
via phone at (914) 835-4484 or e-mail: techsupport@universalremote.com
• U C is not liable for performance issues caused by apps supplied by providers other than U C.
• Modifying the device’s firmware or installing software from unofficial sources may result in device malfunctions
and data corruption or loss. These actions are violations of your U C license agreement and may void your
warranty.
• For use exclusively with compatible U C Control Systems.
The TRF- W2 was designed to work in conjunction with a compatible URC control and automation system. To learn more about it’s
uses and applications, visit the T F-ZW2’s product web-page
• Programmable only by a U C Certified Professional Custom Integrator
To fully control and automate your system, your professional custom integrator must have detailed knowledge of each component,
the local area network (LAN) architecture as well as Wi-Fi configuration and other system connections. Once configured to operate
with your URC control system most changes to the TRF- W2, or the system, may be performed locally (at your home), or from any
remote location (via internet with your permission).
• U C reserves the right to change product features, screen designs, available content, and specifications without
notice
Important Note
By default your professional integrator, after system setup is complete,
continues to have access to your -Wave system via the URC
Web portal. This includes the ability to remotely control
your -Wave devices. URC recommends disabling this access; follow
instructions on page 8 to do so.

™
2
Congratulations
Thank you for purchasing URC’s TRF-ZW2 Z-Wave Gateway. The TRF-ZW2 communicates with your Z-Wave devices and your
compatible URC control system, integrating them seamlessly together into a single user interface for control. Incorporating this gateway as
part of a URC control system enables a myriad of potential additions to your home. Easily expand your system by adding virtually any
Z-Wave enabled device to your connected home. Options include URC’s Vivido Lighting and many third party products such as door locks,
thermostats, sensors, and more. For a complete list of compatible products see the TRF-ZW2’s product web page.
Features and Benefits
Z-Wave Plus Certified
Z-Wave plus and the next generation hardware platform offer enhanced features, capabilities, and improve
the overall end-user experience. For more information visit the Z-Wave alliance web-site.
Improved performance features include:
•Improved battery life for Z-Wave devices not connected to a power source
•Improved range creates a more robust network and reduces the need for Z-Wave repeaters
•Provides more than twice the bandwidth
•Network wide inclusion (pairing) allows for easier installation and expansion
•Enhanced self-healing for improved reliability and user experience
New User Interface
The TRF-ZW2 incorporates the new UI7 User Interface. Modern and attractive, it st reamlines programming and general control of Z-Wave
devices for both the dealer and end-user. The platform includes URC Vivido specific programming: device parameters, easy association,
and intuitive instructions for configuring our lighting devices. UI7 includes an end-user setup wizard that makes it easy for you to add
devices, change scenes, manage your account and more.
New Compact Design
The TRF-ZW2’s smaller form factor allows for more convenient installation in previously prohibitive spaces.
®

Features and Benefits
Easy Setup Wizard
End-User Setup Wizard allows intuitive setup with simple Q&A format; adding devices is made easy with preconfigured settings for many
of the most popular products available in today’s marketplace.
Wi-Fi Enabled
Wi-Fi connectivity allows for optimized placement and simplified installation.
Package Contents
What’s Included with your new product
•TRF-ZW2 Z-Wave Extender
• 12V Power Adaptor
• Ethernet Cable
•Warranty Card
If any of these items are missing, contact URC’s Technical Support Department at (914) 835-4484
3

Device Layout
Connections
• 12V Power eceptacle: connects to the included DC adapter
• Ethernet Port: bridges the TRF- W2 and your local area network (LAN)
• USB Port: provides features and support for advanced applications
4
12V Power eceptacle
J-45 Ethernet Port
USB Port

Device Layout
LED Indicator Lights
Service LED
• On - Cloud service connected and working properly
•Off - No cloud service installed
•Flashing - Cloud service not communicating
Z-Wave LED
•On - Z-Wave function enabled
•Off - Z-Wave function disabled
•Flashing Slowly - Unit in Include (Pairing) Mode
•Flashing Quickly - Unit in Exclude (Unpairing) Mode
Wi-Fi LED
• On - Wi-Fi enabled
• Off - Wi-Fi disabled
• Flashing - Indicates traffic over Wi-Fi
WAN LED
•On - Ethernet is connected
•Off - Ethernet is disconnected
•Flashing - Indicates traffic over ethernet
Power LED
•On - Power on/normal operation
•Off - Power off
•Flashing - Booting/firmware upgrade
Z-Wave LED
Wi-Fi LED
WAN LED
Power LED
5
Service LED

2
Device Layout
Button Layout
Sync button: Used to include and exclude devices from the
Z-Wave network (see page 7 for details)
WPS button: Enables Wi-Fi Protected Setup Mode (should only be
used by qualified integrator, or as directed by URC Technical Support)
eset button: For use only when directed by technical support
Installation
Device Connections
Use the supplied network (Ethernet) cable to connect the TRF-ZW2’s
Ethernet port to your local area network (router or network switch)
Connect the supplied DC adapter to the TRF-ZW2 and plug the adapter into
an AC receptacle
Upon power-up the TRF- W2 checks for an available firmware upgrade. If an
upgrade is available it is installed automatically. The update process takes 15
minutes or less and is indicated by the Power LED flashing. When the Power
LED assumes its normal state (solid green), the TRF- W2 is ready for use.
Sync button WPS button eset button
1
1
2
6

Installation
Setup Through Web-portal
End-user
As an end-user your URC certified custom professional integrator performs the initial setup of your Z-Wave system. An e-mail is sent to the
address you provide your integrator; this includes a temporary password granting you access to the Z-Wave User Portal. Your installer can
assist in familiarizing you with the available features, or more information can be found on the TRF-ZW2’s product web-page.
Professional Integrator
URC certified integrators begin setup of the Z-Wave system by accessing the URC Z-Wave Dealer Portal as prompted by URC software.
Using the T F-ZW2
Manually Including and Excluding Z-Wave Devices
Z-Wave devices are normally paired, or unpaired, with the Z-Wave gateway via the web-portal. It is possible however, to complete the
process manually.
Including a device
1. To include your Z-Wave devices press the Sync button once. The Z-Wave light blinks slowly, once every second, to indicate that it is
in inclusion (pairing) mode
2. Follow the pairing/unpairing instructions for the Z-Wave device (devices have manufacturer-specific instructions)
3. When paired successfully the TRF-ZW2’s Z-Wave LED flashes rapidly for less than a second, then return to inclusion state
4.Pressing the Sync button again returns the unit to normal operating mode
Excluding a device
1. To exclude your Z-Wave devices you’ll need to press and hold the Sync button for 3 seconds. The Z-Wave light blinks faster, twice
every second to indicate that it is in exclusion mode
2. Follow the pairing/unpairing instructions for the Z-Wave device
3. When unpaired successfully the Z-Wave LED flashes rapidly for less than a second, then return to exclusion state
4. Pressing the Sync button returns the unit to inclusion state. A second press returns the unit to normal operating mode
7
Indice
Manuali Portale popolari di altre marche

LST
LST M500RFE-AS Manuale utente

Kinnex
Kinnex Media Gateway Manuale utente

2N Telekomunikace
2N Telekomunikace 2N StarGate Manuale utente

Mitsubishi Heavy Industries
Mitsubishi Heavy Industries Superlink SC-WBGW256 Manuale utente

ZyXEL Communications
ZyXEL Communications ZYWALL2 ET 2WE Manuale utente

Telsey
Telsey CPVA 500 - SIP Manuale utente