URC CAM-DC-O Manuale utente

Owner’s Manual
CAM-DC-O
Vandal/Weatherproof Network Camera

CAM-DC-O Vandal and Weatherproof Network Camera Owners Manual
©2013 niversal Remote Control, Inc.
The information in this Owner’s Manual is copyright protected. No part of this
manual may be copied or reproduced in any form without prior written consent from
niversal Remote Control, Inc.
niversal Remote Control, INC. shall not be liable for operational, technical or
editorial errors/omissions made in this manual.
The information in this Owner’s Manual may be subject to change without priornotice.
Total Control is a registered trademark of niversal Remote Control, Inc.
RC is a registered trademark of niversal Remote Control, Inc.
All other brand or product names are trademarks or registered trademarks of their
respective companies or organizations.
500 Mamaroneck Avenue, Harrison, NY 10528
Phone: (914) 835-4484 Fax: (914) 835-4532

TABLE OFCO TE TS
Introduction 1
eatures and Benefits 1
Parts Guide 1
CAM-DC-O Description 2
CAM-DC-O Description 3
Basic Installation 4
Communicating with the Camera 5
Navigating the Web Interface - Live View 6
Navigating the Web Interface - Admin 7
Specifications 8
Limited Warranty Statement 9
End User Agreement 12
Regulatory Information to the User 13
Declaration of Conformity 14

Page 1
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
Introduction
Congratulations on your purchase of the CAM-DC-O Vandal
and Weatherproof Surveillance Dome IP Camera! The
CAM-DC-O is an outdoor IP camera that allows for seamless
viewing over the network with Total Control interfaces such as
the TRC-1280, TKP-2000, TKP-7000 and future Total Control
graphical interfaces. Once networked, it relays video to these
devices or your PC.
Features and Benefits
• Viewable on Total Control’s TRC-1280, TKP-2000, TKP-
7000 and Complete Control™ KP4000 / 4000C
• Viewable on PCs, iPad®, iPhone® and iPod touch®
• Uses a progressive scan CMOS sensor, H.264/MJPEG
dual encoding and transmission with simultaneous dual
streaming capabilities.
• Camera uses a PoE power supply such as the M SPOE-8.
• The camera has a minimum Lux rating of 4.0 for color.
Parts Guide
The CAM-DC-O Vandal and Weatherproof Network Camera
includes:
1 - CAM-DC-O Outdoor Mini Dome Camera
1 - Attach Guide
1 - Bracket Screws
1 - Allen Wrench
1 - Quick Installation Manual

Page 2
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
CAM-DC-O Description
ront View
Dome Cover: Use the supplied allen wrench to open the
dome cover. Once it is opened, you can adjust the position of
the lens. Use a screwdriver to loosen the lens case and move
the camera lens to the desired position.
Note: If you need to focus the lens, use a Philips screwdriver to
loosen the screw and turn the lens until the image is clear.
LA : Plug an Ethernet cable from the camera’s LAN connection
to a PoE router or switch like URC's M S-POE8. (If a PoE
switch is not used, you must use a PoE injector to supply
power to the camera.)
Dome
Cover
LAN connection

Page 3
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
CAM-DC-O Description
Inside View
Reset: Pressing the “F.D” button will return the unit back to
factory default settings, including the Admin ID and
password.
Reset

Page 4
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
Basic Installation
ollow these basic steps to install the Vandal and
Weatherproof Network Camera CAM-DC-O.
1. Fasten the camera to your planned location.
2. Plug an ethernet cable to the LAN port of the camera.
Note: No separate power supply is needed as the camera
receives power via a PoE supply or a MFSPOE-8 router.

Page 5
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
Communicating with the Camera
An IP address is required to view the camera and modify
surveillance options. Once installed, locate the IP address
assigned by your router (which will differ from the default
address below). Your router contains a DHCP table which
displays each connected device and its IP address. IP
addresses normally resemble 10.20.30.40 or 192.168.1.xx.
or further information, refer to the router’s documentation.
The camera’s factory default options listed below may have
changed depending upon your router settings made by the
Custom Professional who installed your camera.
1. Enter the camera’s IP address into the web browser’s
address bar. RC recommends using Internet Explorer
to view the live surveillance.
2. The IP camera’s web interface opens. You now have
access to the Live View and Administration sections
described next.
actory Default
Admin ID root
Admin password root
IP address 10.20.30.40

avigating the Web Interface - Live View
Select from the options below to modify the Live View.
Channel Control
Displays multiple camera streams. It modifies the primary and
secondary streams (frame rate, image size, encoding, camera name,
rate control mode, image quality and group of pictures structure)
from the Admin page (Device Configuration> Camera & Motion).
Show Full/ ormal Screen
View live video in either full or normal screen. Also capture images
or video by hovering the mouse cursor over the top left corner to
reveal the Snapshot stream and Video icons. Press the Snapshot icon
to save JPEG images or the video icon to save AVI files to your PC.
The maximum AVI recording time is 10 minutes. Press ESC to exit.
Show image in original size
Displays image in its original resolution with zooming capability.
Use the mouse button or keys to zoom-in (+), zoom-out (-), and
original size (/).
Draw image by maintaining aspect ratio
its video to its original size or to the screen
(using the same aspect ratio). No zooming capability.
Draw image by filling the screen
Resizes the video to fill the entire screen. Zooming is not supported.
Enhanced Draw Mode On/Off
Enhances the image quality of a live video smaller than the original size.
About IP CCTV Information
Shows version information for the CCTV viewer.
Control Bar
Page 6
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA

Page 7
CAM-DC-O VA DAL A D WEATHERPROOF ETWORK CAMERA
avigating the Web Interface - Admin
Use the Admin interface to modify advanced features for the
camera. To gain acccess to the Admin site, enter the default
username and password (root and root).
Quick Configuration: A guided step-by-step walkthrough to
setup your camera’s configuration settings. Setup your Server
Name Setup, Date & Time, Network Configuration and IP-CCTV
DNS Setup.
System Configuration: View and/or modify system configuration
settings pertaining to the Server Name, Date & Time, Admin
Password, User Access Control and User Registration.
etwork Configuration: Assign the connection network settings
for IP, Netmask, Gateway, DNS, Network Ports, Bandwidth
Control, Network Status, IP-CCTV DNS and Port orwarding.
Device Configuration: Setup the connection between the
camera and server, by configuring the Serial Ports, adding
Privacy Zone screens, changing the Motion Detection
sensitivity, as well as modifying the camera name and image
quality for the Primary and Secondary streams.
Utilities: View the System Log file, Save the Configuration,
Reboot the camera, revert to the camera’s actory Default
state, and update the camera’s firmware from System Update.