UseTECH FlowTimer+ Remote Set Manuale utente

FlowTimer+ Remote Set
433 Mhz / 2 channel radio control system
for the FlowTimer+ system
Instruction manual

Publisher
usetech GmbH
Tanzplatz 10
D- 55130 Mainz
Telephone:
+49 (0) 6131 - 921325
website:
www. use-tech.com
Document
number
FlowTimer+ Remote_Set_Manual_EN_V1
Original operating instructions
Date of issue
24.11.2020
Print date
24.11.2020
Copyright
usetech GmbH
This documentation including all its parts is protected by copyright.
Any use or modification outside the narrow limits of the copyright
law without the consent of usetech GmbH is inadmissible and liable
to prosecution.
This applies in particular to duplications, translations, microfilming
and storage in electronic systems as well as processing in these.

Table of contents
11/20 FlowTimer+ Remote Set 1
Table of contents
Table of contents.........................................................................1
1General information.............................................................3
1.1 Explanation of symbols .........................................................3
2Technical data......................................................................5
2.1 Radio water detector.............................................................5
2.2 Radio remote control.............................................................5
2.3 Environmental and climate conditions (splitter, receiver)......5
2.4 Lifetime..................................................................................5
3Intended use.........................................................................6
3.1 Unauthorized use ..................................................................7
4System description FlowTimer+ Remote Set.....................8
4.1 Scope of delivery FlowTimer+ Remote Set...........................8
5Installation............................................................................9
5.1 Placement of the radio water sensors...................................9
5.2 Placement of receiver, splitter and cables ............................9
5.3 Electrical connection .............................................................9
5.4 Commissioning....................................................................10
5.5 Teach water sensor.............................................................11
5.6 Teach remote control ..........................................................12
5.7 Deleting the programming...................................................13
5.8 Functional test.....................................................................13
6Operation and function......................................................14
6.1 Operating states..................................................................14
6.1.1 Normal Operation..........................................................................14
6.1.2 Restarting the system....................................................................14
6.1.3 Battery pre-alarm...........................................................................14

Table of contents
11/20 FlowTimer+ Remote Set 2
7Troubleshooting, maintenance .........................................15
7.1 Maintenance........................................................................15
8Packing, transport, storage...............................................16
9Disposal and conformity ...................................................17

General information
11/20 FlowTimer+ Remote Set 3
1 General information
The operating instructions describe the entire life cycle of the
system. Keep this manual in a way that it is easily accessible to
every user and available again for every new owner of the system.
NOTE
The operating instructions contain important safety
information!
Non-observance of these instructions can lead to dangerous
situations.
The operating instructions must be read and understood.
1.1 Symbol explanation
DANGER
Warns of an immediate danger!
Non-compliance will result in death or serious injury.
WARNING
Warns of a potentially dangerous situation!
Failure to observe this warning may result in serious
injury or death.
CAUTION
Warns of a possible danger!
Non-compliance can result in medium or light injuries.
NOTE
Warns of material damage!
Failure to do so may damage the system or equipment.
indicates important additional information, tips and
recommendations that are important for your safety and the
proper functioning of the system.

General information
11/20 FlowTimer+ Remote Set 4
refers to information in this operating manual or in other
documentation.
Action steps
The defined sequence of action steps facilitates the correct
and safe use of the system.
Result
Here you will find the result of a sequence of action steps
described.

Technical data
11/20 FlowTimer+ Remote Set 5
2 Technical data
2.1 Wireless water detector
Operating voltage: 12 V (1x 27A/12V battery)
Battery life approx.: 12 months
Transmission frequency: 433 MHz
Permissible ambient temperature: 0 °C ...+40 °C
Dimensions: L 70 x W 30 x H 20 mm
2.2 Radio remote control
Operating voltage: 6V (2x CR2016 battery)
Battery life approx.: 12 months
Transmission frequency: 433 MHz
Permissible ambient temperature: 0 °C ...+40 °C
Dimensions: L 53 x W 37 x H 14 mm
2.3 Environmental and climatic conditions (splitter,
receiver)
ambient temperature: +5°C - 40°C
Protection class: IP20
Receiver, splitter, I/O cables and connectors: For indoor use
only
2.4 Lifetime
The function of the Remote Set must be checked at the intended
intervals (see also chapter 7.1.)

Intended use
11/20 FlowTimer+ Remote Set 6
3 Intended use
Please observe the instructions in this operating manual as well as
the operating conditions and permissible data according to the data
sheet to ensure that the system functions properly and remains
operational for a long time. In case of non-observance of these
instructions as well as in case of unauthorized interventions in the
system, any liability on our part is void, and the warranty on the
system and accessories is also void!
The FlowTimer+ Remote Set consists ofthree 433 Mhz radio water
sensors (modified Sonoff DW2-RF door sensors), a radio remote
control and a KTNNKG 2 channel radio receiver.
The radio receiver must be located at the installation site of
FlowTimer+. The wireless water sensors can be up to 50 meters
away (depending on the environment) (bathroom, kitchen, etc.).
If a radio water sensor detects conductive drinking water,
FlowTimer+ is immediately shut off via the radio receiver. Any
number of wireless water sensors can be taught-in.
The learnable radio remote control can shut off the water or reset
the FlowTimer+.
The FlowTimer+ Remote Set contains additional parts to split the
FlowTimer+ I/O connector. This allows you to connect additional
FlowTimer+ accessories if required.
An alarm reset can be done via the connected FlowTimer+ or via
the second channel of the radio receiver via radio remote control.
Any other or further use is considered to be improper. usetech
GmbH shall not be liable for any damage resulting from such use.
The risk is borne solely by the user.

Intended use
11/20 FlowTimer+ Remote Set 7
3.1 Use not in accordance with regulations
Unauthorized use in the sense of a foreseeable misuse is
considered to be improper use:
The supplied I/O Splitter must not be used instead of a
FlowTimer+ Hub to connect FlowTimer+ devices to each other!
It can only be used within an I/O connection between
FlowTimer+ and FlowTimer+ Hub to connect accessories!
The water sensors are only suitable for electrically conductive
drinking water.
The FlowTimer+ Protect is not directly supported, but only
indirectly via a group alarm via FlowTimer+ and FlowTimer+
Hub.
No telephones, ISDN, other devices or adapters may be
connected.
The Sonoff 433 RF Brigde cannot be used with the modified
DW2-RF sensor!
Therefore the EweLink App is also not usable!

System description FlowTimer+ Remote Set
11/20 FlowTimer+ Remote Set 8
4 System description FlowTimer+ Remote Set
4.1 Scope of delivery FlowTimer+ Remote Set
Fig. 4.1: Scope of delivery FlowTimer+ Remote Set
1
Radio Receiver
2
Wireless water sensor (3 pieces)
3
Radio remote control (battery included)
4
battery 27A/12V (3 pieces)
5
I/O Splitter
6
I/O connection cable 1m
7
DC extension cable 1m
8
DC input cable
9
DC output cable
10
I/O receiver cable
16
Throwing Antenna