UseTECH FlowTimer+ Detect V2 Manuale utente

FlowTimer+ Detect Set V2
Direct water detection
with the FlowTimer+ system
Operating instructions

Publisher
usetech GmbH
Tanzplatz 10
D- 55130 Mainz
Phone:
+49 (0) 6131 - 921325
Website:
www. use-tech.com
Document
number
FlowTimer+ Detect Set_V2_Manual_EN_V1
Original operating instructions
Date of issue
14.09.2020
Print date
14.09.2020
Copyright
usetech GmbH
This documentation including all its parts is protected by copyright.
Any use or modification outside the narrow limits of copyright law
without the consent of the company usetech GmbH is prohibited
and punishable by law.
This applies in particular to duplications, translations, microfilming
and storage in electronic systems as well as processing in these.

Table of contents
09/20 FlowTimer+ Detect Set V2 1
Table of contents
Table of contents.........................................................................1
1General .................................................................................2
1.1 Explanation of symbols .........................................................2
2Technical data......................................................................4
2.1 Version sensor ......................................................................4
2.2 Environmental and climatic conditions (splitter)....................4
2.3 Service life.............................................................................4
3Intended use.........................................................................5
3.1 Non-intended use..................................................................6
4System description FlowTimer+ Detect Set V2..................7
4.1 Scope of delivery FlowTimer+ Detect Set V2 .......................7
5Installation............................................................................8
5.1 Mounting the FlowTimer+ Detect Set V2 ..............................8
5.2 Placement of splitters and cables .........................................8
5.3 Electrical connection .............................................................9
5.4 Cascading the set................................................................10
6Operation and function......................................................11
6.1 Operating states..................................................................11
6.1.1 Normal operation...........................................................................11
6.1.2 Restarting the system....................................................................11
7Troubleshooting, maintenance .........................................12
7.1 Maintenance........................................................................12
8Packaging, transport, storage...........................................13
9Disposal and EC Declaration of Conformity.....................14

General
09/20 FlowTimer+ Detect Set V2 2
1 General
The operating instructions describe the entire life cycle of the
system. Keep these instructions in a place where they are easily
accessible to every user and available again to every new owner of
the system.
NOTE
The operating instructions contain important safety
information!
Failure to follow these instructions can lead to dangerous
situations.
The operating instructions must be read and understood.
1.1 Explanation of symbols
DANGER
Warns of an imminent danger!
Failure to do so will result in death or serious injury.
WARNING
Warns of a possibly dangerous situation!
Failure to do so may result in serious injury or death.
CAUTION
Warns of a possible hazard!
Failure to do so may result in moderate or minor injury.
NOTE
Warns of property damage!
Failure to do so may result in damage to the system or
equipment.
denotes important additional information, tips and
recommendations that are important for your safety and the
proper functioning of the system.

General
09/20 FlowTimer+ Detect Set V2 3
refers to information in these operating instructions or in
other documentation.
Action steps
The defined sequence of action steps makes it easier for
you to use the system correctly and safely.
Result
Here you will find the result of a sequence of action steps
described.

Technical data
09/20 FlowTimer+ Detect Set V2 4
2 Technical data
2.1 Version sensor
Probes: Stainless steel electrodes
Connection: 1 m cable with FlowTimer+ I/O connector
2.2 Environmental and climatic conditions (splitter)
Ambient temperature: +5°C - 40°C
Protection class: IP20
Location of splitter, I/O cable and connector: Suitable for indoor
use only
2.3 Lifetime
The function of the FlowTimer+ Detect Set V2 must be checked
by a specialist at the specified intervals (see also chapter 9.3.).

Intended use
09/20 FlowTimer+ Detect Set V2 5
3 Intended use
Please observe the instructions in these operating instructions as
well as the operating conditions and permissible data in
accordance with the data sheet so that the system functions
properly and remains operational for a long time. In case of non-
observance of these instructions as well as in case of unauthorized
interventions in the system, any liability on our part is void, as well
as the warranty on system and accessories!
An external water sensor can be connected directly to the
FlowTimer+ I/O port. In this case, however, no FlowTimer+ Hub or
other water sensor can be connected, as the connection is already
occupied.
The FlowTimer+ Detect Set V2 contains additional parts for splitting
the FlowTimer+ I/O connection. Thus, a FlowTimer+ Hub and an
external water sensor, or several water sensors can be connected
in series.
If the water sensor detects conductive drinking water, it is
immediately shut off via the FlowTimer+.
An alarm reset can only be performed via the connected
FlowTimer+ or its supply voltage.
Any other use or use that goes beyond this is considered improper
use. Usetech GmbH is not liable for any damage resulting from this.
The risk is borne solely by the user.

Intended use
09/20 FlowTimer+ Detect Set V2 6
3.1 Use not in accordance with the intended purpose
Unintended use in the sense of foreseeable misuse is considered
to be:
The supplied I/O splitter must not be used instead of a
FlowTimer+ Hub to connect FlowTimer+ devices to each other!
It can only be used within an I/O connection between
FlowTimer+ and FlowTimer+ Hub to connect water sensors!
The water sensor is only suitable for electrically conductive
drinking water.
The FlowTimer+ Protect is not supported directly, but only
indirectly via a group alarm via FlowTimer+ and FlowTimer+
Hub.
No telephones, ISDN, other devices or adapters may be
connected.

System description FlowTimer+ Detect Set V2
09/20 FlowTimer+ Detect Set V2 7
4 System description FlowTimer+ Detect Set V2
4.1 Scope of delivery FlowTimer+ Detect Set V2
Fig. 4.1: Scope of delivery FlowTimer+ Detect Set V2
1
Water sensor with 1 m cable
2
I/O connector for FlowTimer+
3
I/O connection cable 1 m
4
I/O splitter with three I/O ports

Installation
09/20 FlowTimer+ Detect Set V2 8
5 Installation
5.1 Mounting of the FlowTimer+ Detect Set V2
The water sensor can be screwed to a wall, among other things.
To prevent triggering by only superficial moisture, please
keep a small distance between the sensor and the
ground.
If possible, also keep a small distance between the
sensor and the wall to speed up the drainage of water at
the sensor after an alarm.
5.2 Splitter and cable placement
Route the splitter and all I/O cables higher than the water
sensor to protect the splitter and connectors from water
in the event of flooding.
Indice
Manuali Sistema idrico popolari di altre marche

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuale utente

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuale utente

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuale utente

Microline
Microline T.F.C.-4 Manuale

Eureka Forbes
Eureka Forbes Aquaguard Select Manuale utente

Cetetherm
Cetetherm AquaEfficiency Manuale utente