UTC Fire and Security Edwards BPS6A Manuale del prodotto

Remote Booster Power
Supply Technical
Reference Manual
P/N 3100485-EN • REV 04 • ISS 28AUG12

Copyright © 2012 UTC Fire & Security. All rights reserved.
Trademarks and
patents The Remote Booster Power Supply name and logo are trademarks
of UTC Fire & Security.
Other trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the
respective products.
Manufacture
r
Edwards, A Division of UTC Fire & Security
Americas Corporation, Inc.
8985 Town Center Parkway, Bradenton, FL 34202, USA
Certification
FCC compliance Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
FDN
Y
NYC Fire Department Certificate of Approval: MEA 476-91-E XIII
European Union
directives 1999/5/EC (R&TTE directive): Hereby, UTC Fire & Security
declares that this device is in compliance with the essential
requirements and other relevant provisions of Directive 1999/5/EC.
2002/96/EC (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see:
www.recyclethis.info.
2006/66/EC (battery directive): This product contains a battery that
cannot be disposed of as unsorted municipal waste in the European
Union. See the product documentation for specific battery
information. The battery is marked with this symbol, which may
include lettering to indicate cadmium (Cd), lead (Pb), or mercury
(Hg). For proper recycling, return the battery to your supplier or to a
designated collection point. For more information see:
www.recyclethis.info.
Contact information For contact information, see www.utcfireandsecurity.com.

Remote Booster Power Supply Technical Reference Manual i
Content
Important information iii
Limitation of liability iii
Remote Booster Power Supply FCC compliance iv
Introduction 1
Models covered 1
Compatibility 1
Installation procedure checklist 2
Getting started 3
Description 3
Component descriptions 4
Specifications 5
LED indicators 6
Installing the enclosure 7
Installing option modules in the enclosure 8
Installing the circuit board in the enclosure 10
Setting the jumpers 12
NAC Class A or Class B (JP1 and JP2) 12
Ground fault enable (JP3) 12
Battery charging (JP4) 13
UL 864 programming requirements 14
Setting the DIP switches 15
Sense 1 and 2 operation (SW1-1 to 3) 15
Synchronization control (SW1-4) 16
NAC circuit operation (SW1-5 to 8 and SW2-1 to 4) 17
Genesis mode for continuous NACs (SW2-5) 19
AC power loss reporting (SW2-6) 19
Auxiliary control during AC power loss (SW2-7) 19
Class A or B NAC configuration (SW2-8) 20

ii Remote Booster Power Supply Technical Reference Manual
Wire routing 21
Connecting the field wiring 22
AC power wiring 22
Battery wiring 22
NAC Class B wiring 24
NAC Class A wiring 25
Sense circuit wiring 26
AUX power wiring 26
Common trouble relay wiring 27
NAC wiring using CC1(S) modules 29
Installing the 3-TAMP tamper switch 34
Battery calculation worksheet 35
Notification appliance circuit calculations 37
Introduction 37
What you’ll need 37
Worksheet method 39
Equation method 40
Understanding BPS synchronization 43
Connection of booster power supplies 43
Synchronization of visible outputs 44
Synchronization of visible and audible outputs 44
Applications 46
Key 46
Genesis circuit notification 47
Conventional visible and audible circuit notification 48
Conventional visible and audible circuit to Genesis notification 49
Conventional audible or visible circuit to Genesis notification 50
Genesis visible circuit and conventional audible circuit to Genesis
notification 51
Conventional split mode circuit with fault tolerance notification 52
Genesis split mode circuit with fault tolerance notification 53
CDR-3 Coder to Genesis notification 54
CDR-3 Coder to conventional notification 55
CDR-3 Coder to Genesis visibles and conventional audibles 56
Access control power supply 57

Remote Booster Power Supply Technical Reference Manual iii
Important information
Limitation of liability
To the maximum extent permitted by applicable law, in no event will UTCFS be
liable for any lost profits or business opportunities, loss of use, business
interruption, loss of data, or any other indirect, special, incidental, or
consequential damages under any theory of liability, whether based in contract,
tort, negligence, product liability, or otherwise. Because some jurisdictions do not
allow the exclusion or limitation of liability for consequential or incidental
damages the preceding limitation may not apply to you. In any event the total
liability of UTCFS shall not exceed the purchase price of the product. The
foregoing limitation will apply to the maximum extent permitted by applicable law,
regardless of whether UTCFS has been advised of the possibility of such
damages and regardless of whether any remedy fails of its essential purpose.
Installation in accordance with this manual, applicable codes, and the instructions
of the authority having jurisdiction is mandatory.
While every precaution has been taken during the preparation of this manual to
ensure the accuracy of its contents, UTCFS assumes no responsibility for errors
or omissions.
Advisory messages
Advisory messages alert you to conditions or practices that can cause unwanted
results. The advisory messages used in this document are shown and described
below.
WARNING: Warning messages advise you of hazards that could result in injury
or loss of life. They tell you which actions to take or to avoid in order to prevent
the injury or loss of life.
Caution: Caution messages advise you of possible equipment damage. They tell
you which actions to take or to avoid in order to prevent the damage.
Note: Note messages advise you of the possible loss of time or effort. They
describe how to avoid the loss. Notes are also used to point out important
information that you should read.

iv Remote Booster Power Supply Technical Reference Manual
Remote Booster Power Supply FCC compliance
This equipment can generate and radiate radio frequency energy. If the
equipment is not installed in accordance with this manual, it may cause
interference to radio communications. This equipment has been tested and found
to comply with the limits for Class A computing devices pursuant to Subpart B of
Part 15 of the FCC Rules. These rules are designed to provide reasonable
protection against such interference when this equipment is operated in a
commercial environment. Operation of this equipment is likely to cause
interference, in which case the user, at his own expense, will be required to take
whatever measures may be required to correct the interference.

Remote Booster Power Supply Technical Reference Manual 1
Introduction
This installation manual is intended for use by installers and field technicians. It
provides the installation procedures, wiring diagrams, DIP switch settings, etc.
required to install and set up the Remote Booster Power Supply (BPS).
Models covered
The following table lists the booster power supply models that are covered in this
manual.
Catalog number Description
BPS6A 6.5 A booster power supply
BPS6A/230 6.5 A booster power supply
BPS6AC 6.5 A booster power supply
MIRBPS6A 6.5 A booster power supply
MIRBPS6A/230 6.5 A booster power supply
XLS-BPS6A 6.5 A booster power supply
XLS-BPS6A/230 6.5 A booster power supply
EBPS6A 6.5 A booster power supply
EBPS6A/230 6.5 A booster power supply
BPS10A 10 A booster power supply
BPS10A/230 10 A booster power supply
BPS10AC 10 A booster power supply
MIRBPS10A 10 A booster power supply
MIRBPS10A/230 10 A booster power supply
XLS-BPS10A 10 A booster power supply
XLS-BPS10A/230 10 A booster power supply
EBPS10A 10 A booster power supply
EBPS10A/230 10 A booster power supply
Compatibility
The input circuits of the booster power supply can be connected to 12 VDC or
24 VDC systems.
For details about device compatibility, refer to the Remote Booster Power Supply
Compatibility List (P/N 3100656).

2 Remote Booster Power Supply Technical Reference Manual
Installation procedure checklist
Follow these steps to install and set up the booster power supply (BPS).
Verify that all power and field wiring are de-energized before proceeding.
Unpack the equipment.
Review the “Getting started” section.
Review the applications: Review the applications to determine how you want
to use the BPS. See the “Applications” section.
Prepare the site: Make sure the installation location is free from construction
dust and debris and extreme temperature ranges and humidity.
Install the enclosure: See “Installing the enclosure” for enclosure dimensions.
Install option modules if required: See “Installing option modules in the
enclosure.”
Install the 3-TAMP tamper switch (if one is used): See “Installing the 3-TAMP
tamper switch.”
Set the jumpers: See “Setting the jumpers.”
Set the DIP switch options: See “Setting the DIP switches.”
Review wire routing: See “Wire routing.”
Check field wiring for shorts, opens, and grounds.
Connect the field wiring: See “Connecting the field wiring.”
Turn on the AC mains power.
Connect the battery compliment.
Verify that no defaults are displayed.
Test the system for proper operation.

Remote Booster Power Supply Technical Reference Manual 3
Getting started
Description
The 6.5 A and 10 A booster power supplies are designed to extend the power
capacity of an emergency communication, life safety, fire alarm, security, or
access control system. You can activate the BPS from options modules or from a
control circuit. It has four independent NAC/AUX circuits that are supervised,
when configured for NAC. It is also equipped with a fault relay that you can
configure for common trouble (with immediate AC failure indication), or as an AC
mains failure indication relay (with delayed output). The BPS’s sense input #1
also provides a common fault indicator by opening the output side of the sense
circuit.

4 Remote Booster Power Supply Technical Reference Manual
Component descriptions
Figure 1: Components
(1) (2) (3) (4)
(5)
(6)
(7)
(8)(9)
(10)
(11)
(12)
(1) Enclosure: Houses the electronics and two standby batteries
(2) Heat sink: Distributes heat away from the circuit board
(3) Circuit board: Provides connections for all circuits
(4) Tamper switch standoffs: 3-TAMP mounting standoffs
(5) Jumper JP3: Ground fault enable or disable option
(6) AC LED: AC power on
(7) Mounting brackets: Option module mounting brackets
(8) Jumpers JP1 and JP2: Class A or Class B NAC option
(9) DIP switches: Two eight-position DIP switches used for configuration
(10) Circuit LEDs: NAC, battery, and ground fault trouble LEDs
(11) Batteries: Up to two 10 Ah batteries fit in the enclosure. For larger batteries, use an external
battery cabinet (BC-1 or BC-2).
(12) Jumper JP4: Battery charging jumper
Questo manuale è adatto per i seguenti modelli
17
Indice