V-TEK DT607C-S1 Manuale utente

USER MANUAL
DT607C-V1 / 201608
• Please read this manual carefully to ensure safe and correct operation
• Keep this manual for future reference
DT607C-S1 DT607C-S2
DT607C-S3 DT607C-S4
MODEL DT607C
2-WIRE SERIES


CONTENTS
PARTS AND FUNCTIONS
PartsNames 1
Mounting 1
External Motion Detection 2
SETUP INSTRUCTIONS 3
Functions Setting Up 3
Setting Door Station Address 4
Setting Door Station Calling Mode 4
Setting Unlock Mode 6
Setting Unlock Time 6
Setting Nameplate Illumination Mode 7
Setting Night View LED Illumination Mode 7
Setting Ring Tone 8
WIRING 9
Connecting Electric Lock 9
Connecting 1-Monitor Kit 10
Connecting Multiple Door Stations 10
Connecting Multiple Monitors 11
APPENDIX 13
Precautions 13
Specications13
Cable Requirments 14

-1-
Parts Names
PARTS AND FUNCTIONS
[11] [10]
[9]
[1]
[3]
[4]
[8]
[7]
[6]
[5]
[12]
[13]
[2]
[1] Microphone
[2] UNLOCK indicator
[3] CALL indicator
[4] Call button
[5] Nameplate
[6] Front panel
[7] Speaker
[8] Night view LED
[9] Camera lens
[10] Rain cover
[11] Mounting hook
[12] Connection port
[13] Screw hole
Mounting
1 2 3 4 5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
Rain cover
Rainy cover
The distance between
the top of main unit
and rain cover should
be not less than 3mm.
Main unit
Main unit
≥3mm
1. Connect the cable
2. Drill holes in the wall to match the size of screw stoppers,then attach the rain cover and
main unit to the wall.Distance between the top of main unit and rain cover should be not less
than 3mm
3. Install the name plate
4. Attach the front cover to the main unit
5. Use supplied allen key and the screws to x the cover
The installation height is suggested to 145~160cm

-2-
PARTS AND FUNCTIONS
Terminals description
Lock Control Jumper: To set lock type
Motion Detector Connection Port: To connect external PIR motion
detector
Main Connection Port: To connect the bus line and the electric lock
• L1,L2: Connect bus line, no-polarity
• PL: External lock power input, connect to the power positive (power +).
• S+: Lock power(+) output
• S-: Lock power(-) output, connect to the power(-) input of lock(only when lock is powered
from the Door Station)
1 2 3
Lock Control Jumper
PIR Motion Detector
Connection Port
+12V
GND
PIR
L1 L2
PL
S+ S-
Main Connection Port
External Motion Detection
The door station is equipped with a terminal to
connect external motion detector sensor
If the external motion detector is connected to
the system and it detect someone passing by, it
will turn on security light. Additional DT-RLC is
required
12V
Motion
detector
GND
PIR

-3-
SETUP INSTRUCTIONS
Functions Setting Up
KEY_1
KEY_2
KEY_3
KEY_4
KEY_SET
LED_UNLOCK
LED_TALK
LED_NAME
This section explains the settings of each
function. Please refer to the following table.
To perform the settings for the function
you want, you should remove door station
cover plate
Each operation is indicated by the lighting
up of the LED indicator on the unit and by
the sounding of the buzzer.
Order Setting items Setting range Default value
1 Setting door station address 0~3 0
2Setting door station
calling mode Standard/Group calling mode Standard calling mode
3 Setting the unlock mode 0:opened/1:closed 0:opened
4 Setting the unlock time 01 to 99 seconds 1 seconds
5Setting the nameplate
illumination mode On/Off/Auto On
6Setting night view LED
illumination mode On/Off/Auto Auto
7 Setting ring-back tone
Ringing ones
Ring continuously
No ring-back tone
Ringing ones

-4-
Setting Door Station Address
Setting Door Station Calling Mode
Total 4 addresses can be congured. It can be modied either before or after installation.
0 is default, to change the setting, please follow the steps:
UNLOCK Indicator:OFF
TALK Indicator:OFF Buzzer Beep+, Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep+
In standby mode, press
KEY_SET button once
Press KEY_1 button to set
as first door station
Press KEY_2 button to set
as second door station
Press KEY_3 button to set
as third door station
Press KEY_4 button to set
as fourth door station
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep
UNLOCK Indicator:OFF
TALK Indicator:OFF
Buzzer
Beep,Beep,Beep,Beep
ID=0,1st door station ID=1,2nd door station ID=2,3rd door station ID=3,4th door station
SETUP INSTRUCTIONS
• If setting mode has not been exited, you can change the address of door station by pressing KEY1~4
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button four times to exit the setting mode manually
There are two calling modes for door station: Standard calling mode and Group calling mode
Standard Calling Mode is default

-5-
• If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for10 seconds will exit the setting mode automatically
• Press KEY_SET button three times to exit the setting mode manually
SETUP INSTRUCTIONS
Refer to the manual for Video Monitor for more info about monitor address setting
Each call button will respond different addresses when set in different calling modes
Refer to the following for more information
Call buttonA: call the monitor with address 01 by default
Call buttonB: call the monitor with address 02 by default
Call buttonC: call the monitor with address 03 by default
Call buttonD: call the monitor with address 04 by default
Call buttonA: Call all monitors in group address from
00~15 (one of the monitor should be set to 00)
Call button B,C,D: Call all monitors in group address
from 16~31 (one of the monitor should be set to 16)
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button twice
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep+
Press KEY_1 button to
activate Standard calling
mode for door station
UNLOCK Indicator:OFF
TALK Indicator:ON
Buzzer
Beep, Beep
Press KEY_1 button again
to activate Group calling
mode for door station
Press KEY_1
A
B
C
A
B
C
D
A A
B
1.Standard Calling Mode
(Address range 01-04 default)
2.Group Calling Mode
To change this setting, please follow the steps:

-6-
SETUP INSTRUCTIONS
Setting Unlock Mode
There are 2 unlock modes, Normally opened and Normally closed
Normally opened is default.To change
it,
please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+
Press KEY_1 button to set
the unlock mode to
Normally opened
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep, Beep
Press KEY_1 button again
to set the unlock mode to
Normally closed
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually
Setting Unlock Time
Default unlocking time is 1s.Can be changed to anything from range 1s~99s
Follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep,Beep......
Press and hold on KEY_2
button. The time you holding
on is the new unlock time
• When entering time delayed setting, the buzzer soundsonesper second
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually

-7-
SETUP INSTRUCTIONS
Setting Nameplate Illumination Mode
There are 3 illumination modes for nameplate:Normally On,Normally Off and Auto
Normally On is default.To change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+
Press KEY_3 button to set
the nameplate illumination
mode to Normally On
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_3 button again
to set the nameplate illumina-
tion mode to Normally off.
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_3 button again and
again to set the nameplate
illumination mode to Auto
Press KEY_3
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3
circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually
Setting Night View LED Illumination Mode
There are 3 working modes for night view LED indicator:Normally On,Normally Off,Auto
Auto is default.To change the setting, please follow the steps:
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+, Beep
In standby mode, press
KEY_SET button three
times
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep+
Press KEY_4 button to set
the night view LED mode
to Normally On
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep
Press KEY_4 button again
to set the night view LED
mode to Normally Off
UNLOCK Indicator:ON
TALK Indicator:OFF
Buzzer
Beep, Beep,Beep
Press KEY_4 button again
and again to set the night
view LED mode to Auto
Press KEY_4
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing
KEY4 circularly
• The LED_NAME indicator will blink until the setting mode is exited
• No operation for 10 seconds will exit the setting mode automatically
• Press KEY_SET button twice to exit the setting mode manually