1 2 3
65
98
4
7
B0
A
Vanderbilt International (IRL) Ltd.
Card reader
PP500-Cotag & PP500-EM
Installation Guide

PP500 Installation Guide 3
ENG
English
Data and design subject to change without notice.
© 2015 Copyright by Vanderbilt International (IRL) Ltd.
We reserve all rights in this document and in the subject thereof. By
acceptance of the document the recipient acknowledges these rights and
undertakes not to publish the document nor the subject thereof in full or in
part, nor to make them available to any third party without our prior express
written authorization, nor to use it for any purpose other than for which it
was delivered to him.

4 PP500 Installation Guide
ENG
Contents
General ........................................................ 5
About this document............................................................ 5
Safety........................................................... 6
Standards & guidelines.............................. 6
Power supply......................................................................... 8
Cable recommendations ...................................................... 8
Technical data............................................. 9
Reading distances ................................................................ 9
General features ....................................... 10
Power Up ............................................................................. 10
Addressable Entry/Exit (BCLINK)...................................... 10
Programming Mode ............................................................ 10
Timeout Period.................................................................... 10
Exit Programming Mode..................................................... 10
Preset Congurations (short commands) ........................ 11
Installation................................................. 12
Mechanical........................................................................... 12
Wiring ........................................................ 14
DC22 & DC12 connections................................................. 16
DC800 connections............................................................. 16
Granta 4422 connections ................................................... 17
SiPass Integrated ADD5100 connections......................... 18

PP500 Installation Guide 5
ENG
General
The PP500 can be connected to many of the
systems products like Vanderbilt Entro, DC800,
Granta and SiPass Integrated. The PP500 can be
ordered in two different variants supporting two
different reading technologies:
• Cotag technology (both active & passive)
• EM4102 technology
About this document
This document only serves as a Installation Guide
when using the PP500 with the main factory set-
ting and only the “short commands”.

6 PP500 Installation Guide
ENG
Safety
• Read the general safety precautions before
operating the device.
• Follow all warnings and instructions marked
on the device.
• Keep this document for reference.
• Always pass this document on together with
the product.
• The device has been approved for use in the
European Union. In countries outside the EU,
the local conditions and regulations need to be
checked before putting the device into service.
• Please also take into account any additional
country-specic, local safety standards or
regulations concerning project planning, op-
eration and disposal of the product.
• Maintenance work must only be carried out by
trained specialists.
Standards & guidelines
This product complies with the requirements of the
European Directives.
The EU declaration of conformity is available from:
Vanderbilt International (IRL) Ltd.
Clonshaugh Business and Technology Park
Clonshaugh, Dublin 17, Ireland

PP500 Installation Guide 7
ENG
European Directive 1999/5/EC on Radio Equip-
ment and Telecommunications Terminal Equip-
ment (R&TTE):
Compliance with the European Directive 1999/5/
EC has been proven by testing according to the
following standards:
EN 300 330-2 V1.3.1: 2006-04
EN 301 489-3 V1-4-1:2002-08
European Directive 2004/108/EC on Electro-
magnetic Compatibility (EMC):
Compliance with the European Directive
2004/108/EC has been proven by testing accord-
ing to the following standards:
EN 50130-4:1995 + A1:1998 + A2:2003
European Directive 2006/95/EC on Low-Voltage
Directive (Safety):
Compliance with the European Directive 2006/95/
EC has been proven by testing according to the
following standard:
EN 60950-1:2006

8 PP500 Installation Guide
ENG
Power supply
Any power supply connected to the PP500 must
conform to CE regulations regarding safety and
EMC. This includes conformity to SELV (Safety
Extra Low Voltage) according to EN 60950-1.
The supply line fuse shall, independent of host
system, not in any case exceed 10A.
Cable recommendations
The cables used for this product shall be screened
and not exceed 30 m. E g the Belden 9534/9538,
Li-YCY.
The screen shall be connected to any screen con-
nector (if this exist) in a door controller - otherwise
to the back plate of the PP500.
Note! - Due to the risc of potential differences in
the protection earth system of buildings, only one
(1) connection to earth shall be made in a system.

PP500 Installation Guide 9
ENG
Technical data
Power supply: 12 -24 V DC
Min. 10,5 V DC
Max. 35V DC
Power consumption PP500-EM:
24V DC: Typ 17 mA (408 mW), Max*): 31 mA (744 mW)
12V DC: Typ 32 mA (384 mW), Max*): 68 mA (816 mW)
*) While horn sounds
Power consumption PP500-Cotag:
24V DC: Typ 23 mA (552 mW), Max*): 40 mA (960 mW)
12V DC: Typ 44 mA (528 mW), Max*): 90 mA (1080 mW)
*) While horn sounds
Frequency range: EM: 125 kHz
Cotag: 66-132 kHz
Temperature range: -30° C to +50° C
IP Class: IP54
Dimensions (HxWxD) mm: 140x80x40
If needed, complete the installation with ush mounting
kit BB3.
Reading distances
EM4102 (passive): up to 5 cm
Cotag (passive): up to 5 cm
Cotag (active): up to 10 cm

10 PP500 Installation Guide
ENG
General features
Power Up
Power up will give a rising tone from the Buzzer/
Horn. The default power up conguration is
BCLINK.
Addressable Entry/Exit (BCLINK)
When the reader is using BCLINK conguration
the external jumper connections, denes the ad-
dress of the reader whether it is a Entry or an Exit
reader.
Programming Mode
Programming mode is enabled when powering
up the reader with the ‘B’ button pressed for 2
seconds. This is indicated by red and green LEDs
blinking.
Timeout Period
When the reader is in programming mode if no
cards are presented to the reader or short code
keys pressed the reader will automatically time out
and return to normal operation after 60 seconds.
Exit Programming Mode
Programming mode can be cancelled by press-
ing ‘B’ when red and green LEDs are ashing
together.