Vector Fog BY100 Manuale utente

INSTRUCTION MANUAL
CAUTION MARKS
Please read this manual before using this equipment.
Avoid fogging chemicals upwind.
Flammable butane gas (Cartridge Type)
It is advised to wear ear plugs to protect the user from the high noise produced by the machine.
The interior of the machine heats up to extremely high temperatures. Do not add fuel or
chemicals during the operation of the machine or when it is hot after use.
You must wear protective equipment (face/breathing mask, protective clothing, gloves,
etc.) when handling potentially hazardous chemicals.
When fogging outdoors, you should only fog for short periods at a time and when there is not
much wind. When fogging indoors you should start at the furthest part of the building and work
your way back until you get to the entrance or exit.
It is essential to read the chemical manufacturer’s instructions before you start applying, including
diluting ratio and safety precautions.
Only experienced personnel should operate this equipment.
You must exercise caution when connecting the propane/butane canister, in order to avoid the
risk of fire.

Discharge
Point Coil Safety
Mesh
Chemical
Control
Valve
Chemical
Tank
Pump Handle
Gas
Cartridge
Locking
Point
Dilution Tank
(Water or Oil)
Pump
Burner
Solution
Supply Line
2
Customer Service
Vectorfog®
10 Industrial Ave, Suite 4, Mahwah, NJ 07430, USA
Tel: +1 844 780 6711
inf[email protected] www.vectorfog.com
SPECIFICATIONS
BY100 Mini Fogger
2.8 Liters
400 ml
Duel Function: Water or Oil based
2 LPH
Propane/Butane Gas Cartridge
1-5 Liters
1.70 Kg
2.50 Kg
610x175x400 (mm)
Model
Dilutant Tank (Water or Oil)
Chemical Tank
Fogging
Flow Rate
Fuel
Chemical Output
Net Weight
Gross Weight
Dimensions
Accessories
1. BY100 Mini Fogger
2. Plastic Pump
3. Shoulder Strap
4. Manual
Vectorfog® BY100 Mini Foggers are powered by a standard propane or butane gas
cartridge. The gas is ignited by a pietzo and the gas heats the metal coil tube. The water
or oil dilutant is then heated and mixed with the chemical to create a fog or mist. Thanks
to its portability, the BY100 is ideal for fogging pesticides and disinfectants in a multitude
of locations such as in homes, patios, parks, silos, chicken coops and greenhouses.

CHECKLIST BEFORE STARTING THE UNIT
3
Unpacking the Unit
Manual
When unpacking the unit, please make
sure that the machine is not damaged
and that all accessories mentioned in
this manual are not missing.
Fill the Fuel Tank
Unscrew the tank counter-clockwise
from the main body. Fill the tank with
the dilutant of your choice. Water for
water based fogging or oil for oil based
fogging. Do not add more dilutant than
needed. Do not overfill the tank. When
finished with filling the tank, screw the
tank tightly back to the main body in a
clockwise direction.
Dilutant
Tank
Fill the Chemical Tank
(quimicos)
Pre-mix chemical with an oil or water
based emulsifier prior to filling the
chemical tank. Please refer to chemical
manufacturers instructions for correct
ratio. Fill the special chemical mixture
into the chemical tank. It is important
not to add more chemical mixture than
is needed. Please check level on the
window located on the side of the
machine. Maximum level is 350ml.
When you finish filling the tank, close
the tank cap tightly.
Note: Leaving remaining chemicals in
the tank after use could affect the
performance of the machine in the
following session as deposits may
solidify.
Chemical Level
Indicator
Chemical
Tank
Plastic
Pump
BY100 Mini Fogger Shoulder
Strap

4
To Turn Machine On
Connect the propane/butane gas
cartridge to the main body. Make sure it
is locked into position. Turn the gas
supply on by turning the valve counter
clockwise, as shown in the diagram. To
start the machine, press the ignition
switch located on the left hand side of
the machine. It is necessary to keep the
machine on for about 10 seconds (if
water fogging) and/or 30 seconds (if oil
fogging) to warm up before opening the
chemical valve.
To Start Fogging
Once the machine has warmed to the
required temperature, turn the chemical
valve counter clockwise as shown in the
diagram below and press the trigger to
start fogging. When the trigger is
released, the fogging will pause.
Note: When oil fogging, please make sure
the oil has been consumed. Any oil still left
in the coil after use could cause it to block
and not work on the next session.
To Turn Machine Off
Release the trigger. Turn the chemical
supply valve clockwise to stop the
supply of chemical. Turn off the gas
supply by turning the valve clockwise as
shown on the diagram below. Remove
gas cartridge.
Note: When storing the machine, please
make sure no dilutant or chemicals are
left in the tanks.
Chemical Level
Indicator

Part No.
1-1
1-2
Burner Net Set
Burner Control Valve Set
Part Name
Part No.
2-1
2-2
Jet Nozzle
Coil Set
2-3-1 Coil Connecting Bolt
2-3-2
2-3-3
Ring 6mm
Coil Nut
2-3-4 Pump Pipe
2-4 Pump Set
Part Name

Part No.
3-1
3-2
Chemical Control Valve Set
Chemical Tank
Part Name
Part No.
4-1-1
4-1-2
Chemical Supply Pipe
Ring 4mm
4-1-3
4-1-4
Chemical Supply Pipe Nut (S)
Chemical Supply Pipe Nut (B)
Part Name
Part No.
5-1
5-2
Insulator
Ignition Switch
Part Name

Part No.
6-1-1
6-1-2
Case
Pump Handle
6-1-3 Pump Wire
6-1-4
6-1-5
Ball
Pump Plastic
6-1-6 Pump Spring
6-1-7 Chemical Tank Lid
6-1-8
6-1-9
Chemical Control Handle
Chemical Tank Cover
6-1-10 Cover Molding
6-2
6-3
Safety Net
Fuel Tank
6-4 Gas Control Handle
Part Name

PRODUCT WARRANTY
This product is warrantied for twelve months from the date of original purchase. Any defect that arises due to
faulty materials or workmanship will either be replaced or repaired during this period by the seller or authorized
distributor from whom you purchased the unit. Transportation charges or duties shall be borne by Purchaser.
Purchaser must register the product for warranty coverage on the website (VECTORFOG.COM/WARRANTY). Proof
of purchase is required to register.
The warranty is subject to the following provisions:
• The warranty does not cover normal wear, accidental damage, misuse or damage resulting from use for a
purpose for which it is not designed; altered in any way; or subjected to any but the specified voltage if applicable.
• The product must be operated only by trained and skilled personnel and it must be correctly handled and
operated in accordance with the instructions contained within this manual. The functional safety of the unit (e.g.
by trial fogging with water) must be checked before putting the unit in operation. Any loose or leaking valves or
lines should be repaired and fixed. If functional safety is not ensured, do not put the unit into operation.
• The warranty will be rendered invalided if the product is re-sold, fitted with non-original spare parts or damaged
by inexpert repair.
• Chemical solutions must be officially approved for the intended application and the material safety data sheet of
the chemical solution should be checked prior to operation. HOCL (Hypochlorous Acid) is a powerful oxidizing
agent and is not recommended for use with this machine. Using a home-made HOCL solution with this machine is
not covered under our 12 month warranty. If not approved for acid resistance, the pH-value should be limited to a
range between 4 - 10 at 200 PPM. Using solutions out of the pH-value 4 - 10 will make the warranty null and void.
After use, fog with clean water for about 3 minutes to remove any chemicals still left in the system. Ensure all the
water is used up and the machine is dried prior to storage. Damage caused by corrosion will invalidate the
warranty!
• Any formation of aerosols or fogs from flammable substances or acids releasing oxygen and a mixture with air
and/or dust always involves the risk of fire and/or explosion if there is a source of ignition. Observe the explosion
limit of all solutions and avoid over dosage accordingly. Only use non-inflammable liquids (without a flash point)
for treatments in rooms where a dust explosion hazard exists. Unit is not explosion proof.
• Operators owe a duty of care to prevent unreasonable risk of harm or injury. Operators should not fog towards
hot surfaces or electric cables nor fog in rooms where temperatures exceed 35°C. Position the unit in a safe and
upright position with the hand piece hooked or carry it with the strap over your shoulder. In case of stationary use,
do not leave the unit unattended.
• If the machine stops fogging unintentionally, turn off the unit immediately. If the issue persists, contact the
supplier, distributor or Vectorfog®. After a return due to malfunctioning of the unit, the supplier, distributor or
Vectorfog® will inspect the unit to determine whether or not warranty service applies. Upon arrival at the facility,
inspection will take 7 - 14 business days. Vectorfog® will then contact the Purchaser with an evaluation of the
product warranty.
• Specifications are subject to change without notice. The manufacturer disclaims any liability for the incidental or
consequential damages. The warranty is in addition to and does not diminish your statutory or legal rights. In the
event of a problem with the product within the warranty period call the Customer Helpline: (US) +1 844 780 6711

www.vectorfog.com
NL OFFICE | KOREA OFFICE | US OFFICE
TEL: (NL) +31 (20) 899 0992 | (KOREA) +82 (0)70 4694 2489 | (US) +1 201 482 9835
EMAIL: [email protected]
Indice
Altri manuali Vector Fog Macchina del fumo

Vector Fog
Vector Fog C20 Manuale utente

Vector Fog
Vector Fog VECTORFOG H500 Manuale utente

Vector Fog
Vector Fog H100 Manuale utente

Vector Fog
Vector Fog DC20P Manuale utente

Vector Fog
Vector Fog Z500 Manuale utente

Vector Fog
Vector Fog C20 Manuale utente

Vector Fog
Vector Fog C20 Manuale utente

Vector Fog
Vector Fog VECTORFOG H400 Manuale utente

Vector Fog
Vector Fog C20 Manuale utente

Vector Fog
Vector Fog DC20+ ULV FOGGER Manuale utente