Venue Lighting Effects THINTRI 38 LED Manuale utente

THINTRI 38 LED
THINTRI 64 LED
OWNER’S MANUAL
by
TM

2
by
TM THINTRI 38 LED / THINTRI 64 LED
OWNER’S MANUAL
TABLE OF CONTENTS
BEFORE YOU BEGIN .......................................... 3
What Is Included ................................................. 3
Unpacking Instructions........................................ 3
Claims ............................................................ 3
Text Conventions................................................. 3
Symbols .............................................................. 3
Product at a Glance ............................................ 3
Safety Instructions .............................................. 4
INTRODUCTION .................................................. 5
Product Overview................................................ 5
Product Dimensions............................................ 6
SETUP................................................................... 7
AC Power ............................................................ 7
Fuse Replacement.............................................. 7
Power Linking ................................................. 7
Mounting ............................................................. 8
Orientation...................................................... 8
Rigging ........................................................... 8
OPERATION ......................................................... 9
Control Panel Operation ..................................... 9
Menu Map........................................................... 9
DMX Linking...................................................... 10
Configuration (DMX)..................................... 10
DMX Personality and Starting Address............. 10
DMX Channel Assignments and Values ........... 11
8-CH............................................................. 11
3-CH............................................................. 11
Configuration (Standalone)............................... 12
Automatic Programs..................................... 12
Auto-Program Speed.................................... 12
Sound-Active Mode ...................................... 12
Sound Sensitivity.......................................... 12
Preset Color Mode ....................................... 12
Custom Color Mixing.................................... 13
Dimmer Speed ............................................. 13
Master/Slave Mode (wired) ............................... 13
MAINTENANCE.................................................. 14
TECHNICAL SPECIFICATIONS........................ 15
CUSTOMER SUPPORT ..................................... 16
WARRANTY........................................................ 16
The Venue by Proline ThinTri 38 and ThinTri 64 LED Par lights are extra bright, vibrant, lightweight and
compact which makes them great lights for clubs, parties, Houses of Worship and mobile DJs. These units
can be used as a “stand alone” fixtures in sound-activated mode, or controlled via DMX controllers.

3
www.venuelightingeffects.com
BEFORE YOU BEGIN
WHAT IS INCLUDED
• ThinTri 38 or ThinTri 64 LED Lights • Power Cord
UNPACKING INSTRUCTIONS
Carefully unpack the product immediately and check the container to make sure all the parts are in the package
and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear damaged from shipping, or show
signs of mishandling, notify the carrier immediately, not Venue by Proline. Failure to report damage to
the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to shipping, or concealed
damage, file a claim with Venue by Proline within 7 days of delivery.
TEXT CONVENTIONS
CONVENTION MEANING
1-512 A range of values
50/60 A set of values of which only one can be chosen
Settings A menu option not to be modified
MENU > Settings A sequence of menu options to be followed
<ENTER> A key to be pressed on the product’s control panel
ON A value to be entered or selected
SYMBOLS
SYMBOL MEANING
Electrical warning. Not following these instructions may cause
electrical damage to the product, accessories, or the user.
Critical installation, configuration, or operation information. Not
following these instructions may make the product not work,
cause damage to the product, or cause harm to the operator.
Important installation or configuration information. The product
may not function correctly if this information is not used.
Useful information.
PRODUCT AT A GLANCE
Use on Dimmer Sound-Active Master/Slave Auto-ranging
Power Supply User-Serviceable
Outdoor Use DMX Auto Programs Replaceable
Fuse

4
by
TM THINTRI 38 LED / THINTRI 64 LED
OWNER’S MANUAL
SAFETY INSTRUCTIONS
Please read the following Safety Notes carefully before working with the product. The Notes include important
safety information about installation, usage, and maintenance.
• Always connect the product to a grounded circuit to avoid the risk of electrocution.
• Always disconnect the product from the power source before cleaning or replacing the fuse.
• Avoid direct eye exposure to the light source while the product is on.
• Make sure the power cord is not crimped or damaged.
• Never disconnect the product from power cord by pulling or tugging on the cord.
• If mounting the product overhead, always secure to a fastening device using a safety cable.
• Make sure there are no flammable materials close to the product when operating.
• Do not touch the product’s housing when operating because it may be very hot.
• The product is not intended for permanent installation.
• Always make sure that the voltage of the outlet to which you are connecting the product is
within the range stated on the decal or rear panel of the product.
• The product is for indoor use only! To prevent risk of fire or shock, do not expose the
product to rain or moisture.
• Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from
adjacent surfaces.
• Be sure that no ventilation slots on the product’s housing are blocked.
• Never connect the product to a dimmer.
• Make sure to replace the fuse with another of the same type and rating.
• Never carry the product from the power cord or any moving part. Always use the hanging/
mounting bracket.
• The maximum ambient temperature (Ta) is 104 °F (40 °C). Do not operate the product at
higher temperatures.
• In the event of a serious operating problem, stop using the product immediately.
• Never try to repair the product. Repairs carried out by unskilled people can lead to damage
or malfunction. Please contact the nearest authorized technical assistance center.
• To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
• Keep this User Manual for future use. If you sell the product to someone else, be sure that
they also receive this document.

5
www.venuelightingeffects.com
INTRODUCTION
PRODUCT OVERVIEW
THINTRI 38 LED
THINTRI 64 LED
Lenses
BACK PANEL VIEWFRONT VIEW
Display
Menu Buttons
Microphone
DMX In/Out
Fuse Holder
Power In/Out Safety Loop
9.9ʺ
(251.5 mm)
2.9ʺ
(75 mm)
3.3ʺ
(84 mm)
Lenses
BACK PANEL VIEWFRONT VIEW
Power In/Out
Microphone
DMX In/Out
Display
Menu Buttons
Fuse Holder
Safety Loop
8.78ʺ
(223 mm)
3.11ʺ
(79 mm)
3.3ʺ
(84 mm)

6
by
TM THINTRI 38 LED / THINTRI 64 LED
OWNER’S MANUAL
Lenses
BACK PANEL VIEWFRONT VIEW
Power In/Out
Microphone
DMX In/Out
Display
Menu Buttons
Fuse Holder
Safety Loop
8.78ʺ
(223 mm)
3.11ʺ
(79 mm)
3.3ʺ
(84 mm)
Lenses
BACK PANEL VIEWFRONT VIEW
Display
Menu Buttons
Microphone
DMX In/Out
Fuse Holder
Power In/Out Safety Loop
9.9ʺ
(251.5 mm)
2.9ʺ
(75 mm)
3.3ʺ
(84 mm)
THINTRI 64 LED
PRODUCT DIMENSIONS
THINTRI 38 LED

7
www.venuelightingeffects.com
SETUP
AC POWER
The ThinTri 38/64 have an auto-ranging power supply and it can work with an input voltage range of 100 to 240
VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the
current value listed on the product’s back panel, or refer to the product’s specifications chart. The listed current
rating indicates the product’s average current draw under normal conditions.
Always connect the product to a protected circuit (circuit breaker or fuse). Make sure the
product has an appropriate electrical ground to avoid the risk of electrocution or fire.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely
disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat
or dimmer channel serves only as a 0 to 100% switch.
FUSE REPLACEMENT
1. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
2. Pry the fuse holder out of the housing.
3. Remove the blown fuse from the holder and replace with a fuse of the
exact same type and rating.
4. Insert the fuse holder back in place and reconnect power.
Disconnect the product from the power outlet before replacing the fuse.
Power Linking
The product provides power linking via the Edison outlet located in the back of the product.
Please see the diagram below for further explanation.
1st Product
2nd Product
3rd Product
You can power link up to 31
ThinTri-38 or 14 ThinTri-64
products on 120 VAC.
Fuse Holder

8
by
TM THINTRI 38 LED / THINTRI 64 LED
OWNER’S MANUAL
MOUNTING
Before mounting the product, read and follow the safety recommendations indicated in the Safety Notes.
Orientation
The ThinTri 38/64 may be mounted in any position; however, make sure adequate ventilation is provided
around the product.
Rigging
• Before deciding on a location for the product, always make sure there is easy access to the product
for maintenance and programming purposes.
• Make sure that the structure onto which you are mounting the product can support the product’s
weight. See the Technical Specifications for weight information.
• When mounting the product overhead, always use a safety cable. Mount the product securely to a
rigging point, whether an elevated platform or a truss.
• When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity.
• When power linking multiple products, mount the products close enough for power linking cables
to reach.
• The bracket adjustment knobs allow for directional adjustment when aiming the product to the
desired angle. Only loosen or tighten the bracket knobs manually. Using tools could damage
the knobs.
Mounting Clamp
Double-Bracketed
Yoke
Safety Cable
Bracket Adjustment
Knob (x2)

9
www.venuelightingeffects.com
OPERATION
CONTROL PANEL OPERATION
To access the control panel functions, use the four buttons located underneath the display.
Please refer to the Product Overview to see the button locations on the control panel.
BUTTON FUNCTION
<MENU> Press to find an operation mode or to back out of the current menu option
<UP> Press to scroll up the list of options or to find a higher value
<DOWN> Press to scroll down the list of options or to find a lower value
<ENTER> Press to activate a menu option or a selected value
MENU MAP
MODE PROGRAMMING STEPS DESCRIPTION
3-CH d 1–d512 3-channel DMX mode
8-CH 8-channel DMX mode
C
(PRESET COLORS)
C1 Static red
C2 Static green
C3 Static blue
C4 Static cyan
C5 Static magenta
C6 Static yellow
C7 Static white
P--
(AUTO PROGRAM)
P1 3-color program (snap)
P2 3-color program (pulse)
P3 7-color program (snap)
P4 7-color program (fading)
S-- S 1–S100 Program speed for P1–P4
Snd
(SOUND-ACTIVE)
Snd1 3-color program (sound-active)
Snd2 7-color program (sound-active)
SenS u 0–u100 Sound Sensitivity Setting
U--
(CUSTOM COLORS)
r000–r255
Custom static colors
Combines red, green, and blue
g000–g255
b000–b255
dIM
OFF
Dimmer speed mode, fast to slow,
or off
dIM1
dIM2
dIM3

10
by
TM THINTRI 38 LED / THINTRI 64 LED
OWNER’S MANUAL
DMX LINKING
The ThinTri 38/64 works with a DMX controller.
Configuration (DMX)
Set the product in DMX 3-CH or 8-CH mode to control with a DMX controller.
1. Connect the product to a suitable power outlet.
2. Connect a DMX cable from the DMX output of the DMX controller to the DMX input socket on
the product.
DMX PERSONALITY AND STARTING ADDRESS
When selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode
uses. If you choose a starting address that is too high, you could restrict the access to some of the product’s
channels. The ThinTri 64/38 uses up to 8 DMX channels in an 8-CH DMX mode, which defines the highest
configurable address to 505.
To select the starting address, do the following:
1. Press <MENU> repeatedly until 3-CH or 8-CH shows on the display.
2. Press <ENTER> and d 1–d512 will show on the display.
3. Use <UP> or <DOWN> to select the starting address.
4. Press <ENTER>.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Venue Lighting Effects Proiettore