Veria 802 Manuale utente

VERIA
User's guide
Videophone entry station
Model: VERIA 802
Please readthis manualcarefully before you use it
and keep it or a copy thereof in case of further need.

Model: VERIA 232S-W
Content
1.Features and main functions
2.Device function and description
2.1. Description of the equipment
2.2. Wiring
3.Contents of the package
4.Wiring diagram
4.1. Diagram of the wiring of the el.lock
4.11. Connection of the el.lock without an additional source
4.12 Connecting the el.lock with an additional source
4.2 2-wire bus and departure button
4.3 Wiring diagram
4.31. Wiring diagram of the 1-button entry station
4.32. Wiring diagram of the 2-button input station
5.User's guide
5.1.Warning
5.2 Length of connecting cables
5.3 Assembly
6. Technical specification

1. Product characteristics and main functions
← 2 wires, easy to connect
← Support for 2 locks
← 1 MPx HD color CMOS camera
← Automatic night light
←Surfaceand drain mounting possible
2. Features and description of the device
2.1. Description of the equipment
(1)
Speaker
(7)
Mounting hole for the box
(2)
Camera optics
(8)
Mounting boxes
(3)
Microphone
(9)
Front panel screws
(4)
Bell button
(10)
Connecting terminals
(5)
Bell label
(11)
SW1 DIP switch
(6)
Front panel
(12)
Alarm contact "Tamper"

2.2 Description of the wiring
(1)Lock control jumper: Set the power mode for the door lock.
(2)Password reset button: Press and hold the reset button and restart the door station.
The password is successfully reset after two beeps.
(3)Multi-user connector
(4)Connector for external door control
OPEN: Connect the exit button.
SENS: Connect the door status detection switch.
Setting the door status detection function: In the main menu of the 2-wire internal monitor
in Settings"
select the option "Device configuration" , go to the "List of input stations" to mark the door
station, in the menu "Add to the list of monitoring devices" select "Edit" , enter the correct
password and enter the modification interface. Enable "Check door status" and set
"Magnetic Contact Type" to "Normally Open" or "Normally Closed" as needed. Set the time
in "Longest door opening time". If the door is open, the door station detects its condition
and if the door does not close by the set opening time of the door, the door stationwill trigger an
acoustic alarm.
(5)Lock connector: 5-1 is for door lock, 5-2 is for gate lock
(6)2-wire bus connector: Connect the 2-wire bus.
(7)SW1 DIP switch: To set up bus contacts. (Read the wiring diagram in the user guide)
3. Contents of the package

Door station
1pc
Hex wrench
1pc
Screws
4pc
Dowle
4pc
4. Wiring diagram
4.1 Electrical lock wiring diagram
4.11. Connection of the electric lock without additional power supply.
Note: At a distance of up to 5 m of the entrance station and the electric lock, it is not
necessary to use an additional power supply of the lock.
Fig.1
(1) Supported door locks:
A: NC (normally closed) lock,turn off to unlock. DC12V lock support 0.35 A (Max).
B: NO(normally open)lock, on unlocks. DC12V lock support ≤2 A (Instant).
(2) Jumper settings: As shown in Figure 1.
(3) Set the type and time of unlocking the lock:
In the main menu of the 2-wire internal monitor in "Settings", select the option "Device
configuration",
go to the "List of entry stations" to mark the door station, in the menu "Add to the list of
monitoring devices" select "Edit" , enter the correct password and enter the modification
interface.
Select the lock type and set the unlock parameters "Alarm Status" to "On" or "Off" and the
required time in the "Unlock Time" menu.

4.12. Connection of the electric lock with an additional source.
Fig.2
(1) Supported door locks: NO (normally open) lock, it is unlocked by switching on.
AC/DC5V-24V lock support, ≤ 3A (Instant).
(2) Jumper settings: As shown in Figure 2.
(3) Set the type and time of unlocking the lock:
In the main menu of the 2-wire internal monitor in "Settings", select the option "Device
configuration",
go to the "List of entry stations" to mark the door station, in the menu "Add to the list of
monitoring
device" select "Edit" , enter the correct password and enter the modification interface.
Select the lock type and set the unlock parameters "Alarm Status" to "On" or "Off" and the
required time in the "Unlock Time" menu.
Set up Jumpers
Power
Gate Lock
Door Lock

4.2 2-wire bus andodz ozi button
(1) Outgoing button:Press the exit button to unlock the door or gate. To select a door or gate
lock, go to the "Entry stations list" section of the
2-wire internal monitor to "Outgoing button type".
(2) The 2-wire bus does not have polarity.
(3) 2-wire bus contact settings: You must have the 2-wire bus contacts set up correctly. The
last monitor on the 2-wire bus should have the SW1 switch set to ON, see Figure 1.
Other monitors shouldalso have the SW 1 switch set to OFF, see Figure 2.
Note: The SW1 switch is on on by default.
Figure (1) Figure (2)
SW1 ON SW1 OFF

4.3 Wiring diagram
4.31 Single-pressure input station wiring diagram
(A) 1 monitor and 1 entry station
(A-1) DC 24V ,1A Adapter Power Supply
(A-2) Power supply to DIN rail DC24V, 1A

(B) 2 monitors and 1 entry station
(B-1) DC 24V ,1A Adapter Power Supply
(B-2) Power supply to DIN rail DC24V, 1A

(C) 5 monitors and 1 input station (maximum 5 monitors possible, see Figure 1)
(D) 4monitors and 2 entry stations (see Figure 2)
Figure 1 Figure 2
Note: For the specified wiring B and C, the ROOM ADDRESS on all monitors must be set to
the same value. When you press the button at the entrance station, all monitors will ring.