Vertex PWC3000 Guida rapida

VERTEX
Water Products
PureWaterCooler
Water Dispenser
OWNERS INSTALLATION
MANUAL
™
VERTEX WATER PRODUCTS
Models
PWC3000/2000/600
3 Temp - Room, Hot, Cold
PWC1000/1010/500
2 Temp - Hot, Cold
Montclair, CA - USA

WARNING
1) Installing this cooler in an area were water may cause severe or costly dam-
age is not recommended. If Installation of this cooler is in an area where incidental
water spillage may cause severe or costly damage it is recommended that a water
detector and shut-off valve accessory be installed as well. Vertex P/N LC-8021
2) Water supply connection to coolers are to be made with the flexible plastic
tubing provided. If connecting a hard copper line to cooler connection the Bulkhead
fitting on back of cooler must be replaced with a proper metal fitting.
3) Do not position the cooler where it can be hit or bumped by Vacum cleaners
or floor waxing machines This can cause breaks in the waterline, connection fittings
and compressor tubing.

Table of Contents
1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 2
2.0 Receiving . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 3
3.0 Description, Model 2000 and 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 3
4.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 10
5.0 Description, Model 1000 and Model 1010 . . . . . . . . . . . . . . . . . . . pg. 12
6.0 Other Models 500/600/1000RF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 15
7.0 Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 16
8.0 Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 16
9.0 Cleaning and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 18
10.0 Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 19
11.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 20
12.0 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 21
List of Figures
Figure 1. Assembly Drawing, Model PWC 2000 and PWC 3000 . . pg. 4
Figure 2. Flow Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 5
Figure 3. Filter Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 5
Figure 4. Installation Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 6
Figure 5. Water Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 7
Figure 6. Drain Connections for RO filter . . . . . . . . . . . . . . . . . . . . . . pg. 8
Figure 7. Quick Connect Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 9
Figure 8. Model 1000 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 12
Figure 9. Water Connection / 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 13
Figure 10. Front of Model 1000 cooler with door opened . . . . . . . . . . pg. 14
Figure 11. RO Membrane Installation . . . . . . . . . . . . . . . . . . . . . . . . . . pg. 17
– 1 –

1.0 INTRODUCTION
The VERTEX Pure Water Cooler products are a means to produce and dispense
good-tasting, safe water without using “bottles of stored water”.
The Pure Water Cooler taps into your city or well water supply to efficiently fil-
ter out tastes and odor, and to remove molecular contaminants by using reverse
osmosis technology: The Models are:
2000 and 3000 Model. These are 3-temperature units which provides room tem-
perature filtered water, chilled (cold) water, nominally at 44ºF, and hot water, nomi-
nally at 180ºF. In addition, it has a re-boil function which brings the hot water to boil
temperature of 212ºF. There is also a room temperature spigot.
1000 Model. This is a two temperature unit which provides chilled water nom-
inally at 44ºF and dispenses hot water at nominally 180ºF.
1010 Model. This provides chilled water at nominally 44ºF and room tempera-
tures. No hot water is provided.
All three models are made as “R” or “F” versions. The “R” versions have reverse
osmosis filtration which makes good tasting, safe water from city or well water. This
consists of a 5-micron sediment filter, a carbon (GAC) 10-micron filter and a 50-gal-
lon per day RO membrane. The filters remove sediment and dirt and the taste and
odor of chlorine and other contaminants. The reverse osmosis stage removes mole-
cular contaminants from the water. The “R” version requires a drain line connection
to the drain trap to remove rejected water to the sewer.
The “F” version has the sediment and carbon filters, but not the RO membrane;
therefore, it does not require a drain line connection.
CAUTION: The filter version “F” must be used only with softened water or
water that has less than 3.5-grains of hardness to prevent scaling and premature
burnout of the heating elements.
There are 3 other models, all versions of the basic models described above:
500 Model. This is a countertop model of the Model 1000 2-
temperature system.
600 Model. This is a countertop model of the Model 2000 3-
temperature system.
1000R/F Model. This is a Model 1000 2-temperature model with a
0.5 cu. ft. refrigerator at the bottom of the cabinet
instead of a filter.
The above three models do not have filters; they require that the pure water be
made externally and supplied to the Pure Water Cooler. An option is available which
adds a filterpack system that can be mounted on the backside of the cooler.
Please read all the instructions in this manual before operating this unit.
– 2 –

2.0 RECEIVING THE COOLER
2.1 Unpacking (All Models)
The PureWaterCooler™ is shipped completely assembled and ready to operate.
Remove the top of the box and slide the PureWaterCooler™ out and save the box and
packing materials.
2.2 Inspection
Inspect the cooler for shipping damage. Look at the exterior panels to see if they
have been dented or damaged. Check the dispensing spigots in the front. Open the
bottom panel to assure that the filter system is intact. For Model 2000 only look
below the filter assembly in the back to see if the compressor is secure and has not
broken from the mounting. Inspect filter system to see that nothing is damaged or dis-
lodged from shipping.
3.0 Description (Model 2000 and 3000)
3.1 Description
The assembly drawing is shown in Figure 1. The Model 2000/3000
PureWaterCooler™ has 3 tanks There is a main holding water tank with float valve mech-
anism which controls a solenoid valve on the water feed line to maintain a constant level
of filtered water. There is a separate hot tank with internal heaters and a cold tank, cooled
by external coils. The hot tank is at the top level of the cooler, and has a vent hole to per-
mit hot water vapors to exit. The cold tank is lower inside the cabinet. Both tanks are fed
by gravity from the main holding tank. The controls for the cooler are on the front panel
as shown in Figure 1.
– 3–

The internal flow of water to the tanks and dispensers is shown in Figure 2. The
arrangement of the water filter system in the bottom of the cabinet is shown in Figure 3.
This is where ordinary city or well water is converted into good tasting, clean, safe
drinking water.
– 4 –
Figure 1
Assembly Drawing PWC 2000 & PWC 3000
COVER
SNAP-ON
TOP COVER
STEAM EXHAUST
COVER
HOT WATER
TANK COVER
HOT WATER
TANK
MAIN WATER
TANK COVER
MAIN WATER
TANK
CONTROL PANEL
MAIN OUTLET
TUBE
COLD WATER
RELEASE LEVER
ROOM WATER
RELEASE LEVER
HOT WATER
RELEASE LEVER
CUP BASE
SNAP-ON
FRONT PANEL RELEASE BUTTONS
WATER LEVEL INDICATOR
CONTROL PANEL

– 5–
Figure 2
Flow Schematic (Model 2000 & 3000)
Vent Float Type
Water Level Control
Main Water Tank
Cold Tank
Electric Heating
Coil Inside Tank
Check Valve
Drain
Water Spigots Purified Water Inlet
(from filters)
Hot Room Cold
Figure 3
Filtration Schematic. Front of cooler with panel removed.

3.2 Positioning the Cooler
There are some precautions in locating and using the PureWaterCooler™. See
the items in Figure 4 below. In addition, the cooler must be located near the supply
water, and for the “R” version with reverse osmosis filter, there must be access to a
drain trap to which the reject water from the RO is delivered. Normally, this can be
found in a bathroom, or kitchen sink. Flexible 1/4-inch plastic tubing may be used
for the feed and discharge connections. Normally, these connections should be with-
in 25-feet of the cooler.
– 6 –
Do not touch STEAM HOLE or open
HOT WATER TANK COVER while
dispenser is in use (Model 2000)
Be sure to use correct power volt-
age, plug dispenser’s power plug
directly into electrical socket.
Figure 4
Installation Precautions
Provide a minimum of 4 inches of
space between wall and dispenser
Do not put dispenser in a hot place-
near stove or radiator. Do not put hot
plate on top lid, or lighted cigarette

– 7 –
3.3 Cooler Water Connections
(See Fig.5) When received, the water connections on the back have color coded
tube sections with red shipping plugs in them. These tube sections must be removed
before making water connections. To remove the tube sections see figure 7
“Disconnect”. The 1/4" plastic tubing should be used for making the Feed Water and
Drain connections. If hard copper tubbing is used for the Feed Water and Drain con-
nections the bulkhead fittings must be changed to a metal fitting.
.
Figure 5
Back View of Cooler Water Connections

3.4 Feed Water Connections
To connect the feedwater, use the supplied self-piercing saddle valve to connect
to the cold water supply line under the sink. Attach the 1/4-inch tubing to the com-
pression fitting on the side of the valve. Clamp the saddle valve over copper or plas-
tic feed line (cold water only). Turn the handle on the valve until the needle stem
pierces the tube. Then retract the needle 1-2 turns to start water flow. See Photo inset.
3.5 Drain Connection (Applies to all models with Reverse Osmosis (R-version))
The black drain line in the back (Fig. 5) must be hooked to the drain line ahead
of the normal sink water trap.
See Figure 6 below. Place the 2 part drain saddle on the drain pipe before the
drain trap. Allow proper space for the drilling operation. Tighten the saddle bolts
evenly on both sides. Using the opening in the drain outlet saddle as a guide, drill a
1/4” hole in the drain pipe. Clean any debris out of the drain saddle connection.
Connect the drain line to the cooler using the 1/4” black tubing supplied.
– 8 –
Figure 6
Drain Connections for RO filter
Vertical
Mount
Foam
Sealing
Washer
Compression
Fitting
1/4” tube
(black)
Horizontal
Mount
Do Not
Mount Here
Disposal
Sink Sink
Maximum Displacement
from Top Center – 30˚
RO Drain Line
Valve with
Piercing Point
1/4” Line to Cooler
Saddle Valve
Clamp
Copper
Water
Line
Questo manuale è adatto per i seguenti modelli
5
Indice
Altri manuali Vertex Distributore d'acqua

Vertex
Vertex PWC-7000 Manuale utente

Vertex
Vertex PWC600 Manuale utente

Vertex
Vertex PWC-450 Manuale utente

Vertex
Vertex PureWaterCooler PWC-3500 Guida rapida

Vertex
Vertex PureWaterCooler PWC-1800 Manuale utente

Vertex
Vertex PureWaterCooler PWC-400 F Guida rapida

Vertex
Vertex PWC-450 F Manuale utente

Vertex
Vertex PureWaterCooler PWC-400 Manuale utente

Vertex
Vertex PureWaterCooler PWC-8000 Guida rapida

Vertex
Vertex PWC-500 Manuale utente