Vesta Pro 600 VAC Manuale utente

Vesta Pro 600 / 800 VAC
Uninterruptible Power System
USER MANUAL
USER MANUAL


IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS –This manual
contains important instructions for models
Vesta Pro 600/800VAC that should be
followed during installation and
maintenance of the UPS and batteries.
Safety – CAUTION!
This UPS utilizes voltages that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user serviceable parts.
Only factory service personnel may perform repairs.
Internal battery voltage is 12Vdc. Sealed, lead-acid, 6 cells battery.
Connection to any other type of receptacle other than a two-pole,
three-wire grounding receptacle may result in s shock hazard as well
as violate local electrical codes.
In the event of an emergency, turn the power switch to the “off”
position–on and disconnect the power cord form the AC power
supply to properly disable the UPS
Do not allow any liquids or any foreign object to enter the UPS. Do
not place beverages or any other liquid-containing vessels on or near
the unit.
This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in locations where there is standing or
running water, or excessive humidity.
Do not plug the UPS input into its own output.
Do not attach a power strip or surge suppressor to the UPS.
Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum
cleaners to UPS
To reduce the risk of overheating the UPS, do not cover the UPS’
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space heaters
or furnaces.

Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
Do not dispose of battery or batteries in a fire. The battery may
explode.
Do not open or mutilate the battery or batteries. Released
electrolyte is harmful to the skin and eyes. It may be toxic.
A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when working
on batteries :
1) Remove watches, rings, or other metal objects from the hand.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on the top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminal.
Servicing of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep
unauthorized personnel away from batteries.
When replacing batteries, replace with the same number of the
sealed lead-acid batteries.
This pluggable type A equipment with battery already installed by the
supplier is operator installable and may be operated by laymen.
During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads does
not exceed 3.5mA.
The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.

System Description
Front Panel—
1. LCD Back-Light
2. Power “ON/OFF” Switch
Back Panel—
1. Communication Port(Option)
2. Modem/Phone Line Surge Protection
3. AC Output
4. AC Input
5. FUSE
6. BREAKER

Installation and Operation
Installing the UPS is as easy as following the steps shown. Be
aware of the Power Switch must be kept in the “ON” position,
otherwise, the UPS will be disabled and your equipment will not be
protected during a power failure.
1. Inspection
Remove the UPS from its packaging and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
repack the unit and return it to the place of purchase.
2. Placement
Install the UPS unit in any protected environment that provides
adequate airflow around the unit, and is free from excessive dust,
corrosive fumes and conductive contaminants. Do not operate your
UPS in an environment where the ambient temperature or humidity is
high. On the other hand, place the UPS unit away from monitor at least
20cm to avoid interference.
3. Charging
This unit is shipped from the factory with its internal battery fully
charged. However, some energy may be lost during shipping so the
battery should be recharged before using it. Plug the unit into an
appropriate power supply and allow the UPS to charge fully by leaving
it plugged in for 8 hours.

4. Computer Connection
Connect one computer-related device into each of the power
receptacles supplied on the back of the UPS (maximum of three
devices).
5. Modem/Phoneline Connection
Plug incoming internet line into the “In” socket at the back of the UPS.
Use one more Internet line cable and plug one end of the Internet line
cable to the “Out” socket at the back of the UPS. Plug the other end to
the modem input socket as shown.
6. Serial Cable Connection
To allow for unattended system shutdown for your operating system,
connect the serial cable as per diagram below.

7. Turn On/Off
To turn on the UPS unit, press the power switch lightly. To turn off
the UPS unit, press the power switch again (When swith ON,The LCD
lighting.)
8. LCD Display Specification
When LCD start to work, it will display all information for 3s
a. When in normal mode, it will display as below.

b. When in AVR mode, it will display as below. And the mark
will flicker every 1second.
c. When in battery mode, it will display as below. And the mark
will flicker every 1second.
Note: If I/P-V<20V,input voltage will display “000”
d. When in off charging mode, it will display as below.
Note: the output voltage always is displayed as “000” in off
charging mode.
e. When in fault mode, it will display as below. “FAULT”
character and the reason of fault only.

6).Load level definition:
Load LEVEL Load bar Indication
0%~25%
25%~50%
50%~75%
75%~100%
7).Battery capacity definition:
Battery LEVEL Battery bar Indication
Battery voltage≤11V
11V≤Battery voltage≤11.5V
11.5V≤Battery voltage≤12.5V
Battery voltage≥12.5V
8).When over load, the mark will flicker every 1second.
9).When battery low, the mark will flicker every 1second.
Questo manuale è adatto per i seguenti modelli
1
Indice
Altri manuali Vesta UPS
Manuali UPS popolari di altre marche

Pylontech
Pylontech Victron & Pylontech US5000 Manuale utente

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manuale utente

Mecer
Mecer ME-1000-WTU Manuale utente

Mustek
Mustek PowerMust 530(B) Plus Manuale di installazione e funzionamento

Emerson
Emerson Liebert NXL series Manuale utente

MAKELSAN
MAKELSAN BOXER SERIES Manuale utente