1. Client PC requirement
Minimum requirements for a monitoring client PC
OS: Windown 10 64 bit
CPU: I5
Memory: 8G
Graphics card: nVIDIA independent/video memory 2G,
Ethernet Card(NIC): 100Mbps

2
2. Product dimension and appearance
Unit (mm)
USS-TIC500
1 Infrared camera lens
2 visual camera lens
3 Power connector
4 Network connector

3
3. Installation
The distances in below picture indicate the optimal
distance between objects, the black body and the
camera.
4. Mounting brackets and equipment
Please make sure the power is off before the
equipment is installed. The equipment installation steps
are as follows:
(1) Install the device on a tripod or stand.
(2) Connect the network cable and power cable.
(3) Start the PC, double-click the desktop startup icon,
the software automatically connects to the device, and
the system can work normally.
PC Client
(Software Only)
Blackbody
Thermal Camera

4
5. Install the black body
Please make sure the power is disconnected before
installing the black body. The equipment installation
steps are as follows:
(1) Set up on a tripod or stand.
(2) Install the black body on the prepared tripod.
(3) Connect the black body power cord and turn on the
black body switch.
6. Software start interface
Description
1. Tool list
2. Record button, infrared / visible light image can be
recorded for convenient secondary analysis
3. Alarm history picture
4. Real-time infrared image
5. Real-time visible light image
1
2
3
45
6
78

5
6. Focus control button to adjust the sharpness of
human infrared imaging
7. Alarm capture: infrared image
8. Alarm capture: visible light
Explanation:
The alarm snapshot displays the currently captured
alarm image by default; you can also double-click any
picture in the "Alarm History Picture" to zoom in to the
bottom for viewing and analysis.
Icon list
No
Icon
Description
1
Add analysis: Click the icon and
pop-up menu button , you
can draw point analysis, line analysis,
frame analysis, circle analysis on the
infrared chart for point or area
temperature measurement
2
Area arming: Click the icon to arm
the area, and the pop-up menu button
will automatically add 3
* 3, 4 * 4, 5 * 5, 6 * 6, 8 * 8 grids to the
infrared image. Capture the highest
temperature. This mode is suitable for
places where there are a lot of
detected targets, and multi-zone
temperature measurement is
performed at the same time.
3
Face recognition: Enable face
recognition mode, automatically draw
an analysis frame on the face area,
and display the highest temperature in

6
the area
4
Delete analysis: delete all analyses
(including points, lines, boxes, circles)
5
Hide / show analysis
6
Hide / Show Blackbody: After enabling
blackbody correction, click the icon
to control the display / hide of the
blackbody area on the infrared image.
To enable blackbody correction, you
can "Enable external blackbody
calibration" in "System Settings"-
"Temperature Parameters" The next
button to "ON"
7
System settings: You can set and view
the "temperature measurement
parameters", "analysis settings",
"alarm settings", "other settings",
"about" in order.
8
Color palette: five pseudo-color
switching of iron red, rainbow, medical,
black hot, and white hot
9
Blanks: perform blanking and
temperature correction
10
Take a photo: take an infrared + visible
light photo
Historical picture alarm
When the temperature of the human body exceeds the
set 37.5 ℃, it will alarm and automatically capture the

7
picture and display it in the right area of the interface.
7. Tips
1. Avoid measure body temperature ;
- After running or exercising for a long time
- After stay in an air-conditioned environment
2. Increase accuracy of measuring when hot or cold
- When the body temperature is too low, for example, in
the morning and evening in winter, when the thermal
imager measures the temperature, the measured
person needs to pull down the collar slightly, which can
accurately reflect the body surface temperature;
*When the temperature is around the room temperature,
measuring the forehead can accurately reflect the body
surface temperature.
3. Remember, the forehead temperature is lower than
the axillary temperature.
The body surface temperature is measured. The
normal forehead temperature is about 2 ° C lower than
the temperature of the armpit, and the forehead is
greatly affected by the environment. Therefore, it is
normal to refer to the temperature of the armpit as a
medical measurement in clinical clinics.
www.videosec.com