Vinteck V-10 CLIPPER Manuale utente

Vinteck sas
Di Guido Michetti & C.
10128 Torino Corso Vittorio Emanuele II, 123
Tel. + 39 – 339 7626891 fax + 39 - 011 – 547712
Laboratorio Via Limone 22 10141 Torino
Nr. Iscrizione RAEE IT08020000002500
(web) http://www.vinteck.com
(e-mail) [email protected]
V-10 CLIPPER
True-bypass MIDI switching Pedalboard
User manual
Ed. 01 rev. 4
SW: DCEA - 0862

Vinteck
V
-
10 CLIPPER
pag.2
Edizione 01 revisione0
_______________________________________________________
Contents
1 Instrument’s marking pag. 2
2 general warnings pag. 3
3 instructions manual pag. 3
4 technical description pag. 4
5 installation and connections (wiring) pag. 5
6 programming and MIDI manager pag. 8
7 spare parts pag. 13
8 warranty terms and conditions pag. 14
9 support pag. 14
_______________________________________________________________
1-instrument marking.
V-10 got in back side a little non removable area with serial and years of building.
It is very important to report this information in case of need of technical supply.
2- general warnings
o please read the operator manual before starting the use of V-8 and follow the
informations.
o Maintenance must be operated ALWAYS with the instrument not connected
to power supply
Thank you very much for purchase of V-8 pedalboard.
We really hope that it will be good friend for several ours of music. We ask you to
write us by email at [email protected]
any problems or any ideas about
hardware & software you think may be useful to us to built a better product.
We are anytime avalaible for any help you may need about how to use the V-8
Keep on rockin’ (blues, jazz, latin, fusion….)
Guido Michetti

Vinteck
V
-
10 CLIPPER
pag.3
Edizione 01 revisione0
V-8 is powered by an external 12 VDC 500mA. In no any case external power supply
must be opened or dissasembled.
In no any case the power plug and switch must be disassembled.
Vinteck declines all responsibility for damages to persons, animals and things caused
by the non-observance of such a provision.
Warning
- Use of the machine by not properly trained staff.
- Improper use of the machine.
- Electric energy defects
- Repairing and changes made without authorisation.
- Use of not original or not specific for the model parts.
- Partial or total non-observance of the instructions.
- Use of the machine against national specific laws.
- Calamity and unusual events.
Remaining risk
Definition of remaining risk: “A danger not completely reducible from the designing and the
safety devices, i.e. potential and not evident danger”.
Since the productive aiming, the mechanical qualities and the presupposed proper usage we
didn’t find any remaining risks, both during the design and the tests.
Anyway, we recommend:
- to let only trained staff using the machine;
- to check that the machine is supplied by an grounded single-phase electrical cable and the
plug has an effective earth terminal.
3- instructions manual
3.1 This manual is addressed to following subjects:
- Owner;
- Operators.
- Technical builder
3.2 Aiming of details in I.M.
The manual contains a clear description of all technical specifications of the machine aimed
at the transport, adjusting, maintenance, caution, location of remaining risks.
3.3 Using limits of I.M.
This manual can never replace an adequate experience of an operator and so it can only be
a memorandum of the main operations. We specify, moreover. That I.M. mirrors the technical
data at the moment of the purchase of the machine and that the manufacturer has the right to
bring up-to-date I.M. and machines without conform I.M. and previous models.
3.4 How to keep this I.M.
The operating instruction manual has to be kept in perfect state and has to be always
available for consultation. It has to follow the machine in case of transfer of property. It has to
be kept until the demolition of the machine itself,
To order the up-to-date versions of I.M. and for any further information, please contact
Vinteck sas or the nearest Vinteck sas dealer. We will be pleased to receive your
suggestions to improve our quality.

Vinteck
V
-
10 CLIPPER
pag.4
Edizione 01 revisione0
Note for the use of this machine in a foreign country: contingent laws and restrictions in place
for this kind of machine in the Country where it is used have to be respected also in the case
are not mentioned in this manual.
New updated release of the manual will be available on www.vinteck.com
4- V-10 CLIPPER : technical description
True bypass system, working with silver golden relays.
10 programmable loops, plus 2 extra loops for amps send return connections or non
automated effects. Loop 9 and 10 are stereo. A/B – A+B out controls.
It’s possible to connect 6 pedals in front of amps an 4 in effects loops, or 8 and 2. Otherwise,
all 10 in line in front of amp.
4 programmable switch completely independent from loops, for amps channel control.
Tuner OUT with MUTE Function MUTE activavle on flight, or programmed.
Programmable Buffer (max +4dB) indipendent for each patch.
Stereo OUT or programmable A/B A+B.
Any combination between loops, switch and MIDI program change is possible.
On any programs (1 to 120) it’s possible to assign any program change (MIDI MAPPING)
and up to 5 control change with independent channel and value.
12 banks, 10 programs each, total 120 programs.
Each bank may be activated or deactivated (form 0 to 11).
Direct acce on the fligh on loop, with MODE function program/loop
MIDI TAP TEMPO with external pedals, Control Change is assignable from 1 to 128.
MIDI channel manager input, output e 0/1 assignament.
MIDI external expression pedal managing, with Continuos control change
MIDI IN and MIDI OUT with eco THRU (all incoming command comes send out as they are)
High visibility LED display. 3 digit for programa number, up to 7 characters per program.
All programming operations may be done standing up.
External Power supply, 12 VAC or unstabilized DC, 600mA
Dimension 43 x 12 cm. High 4.5/6 cm.
5- installation and wiring
All connection are on the back of V-10 CLIPPER
Low from right to left of image::
Power IN Power supplì input. 12VAC or DC 0.6 A (note: may ne power as well in AC or DC. It is possible
to use lower power supply of 0.6 A, keep in mind that in that case will be not possible to activate in
same time all switch and loops. When power is connected V10 Clipper is active.
WARNING: Never open the external power supply. Inside there is 230 or 117 Volt power.
Opening of power supply is cause of warranty decline.
MIDI OUT MIDI out socket
MIDI IN MIDI IN socket

Vinteck
V
-
10 CLIPPER
pag.5
Edizione 01 revisione0
MN ST MONO STEREO switch. (in MONO connections 9R-R/S e 10R-R/S (right canne) are
deactivated, only left channels works. OUTPUTS A and B got same signal coming fron 9 and 10
left loops.
EXT SW external tap tempo temporary input
Exd expression pedal inputo (25 Kohm raccomended)
S1-2-3-4 Normalli Open contacts. To be use for amp channel, or any similar application.
OUT R OUT L signal outputs. OUT L = OUT A, OUT R = OUT B (on pedals indicated as A and B)
- LOOP1-10 loops managed by buttons 1 to 10
S SEND Segnal to input of effetc
R RETURN Segnal back from effect.
- X LOOP fixed llops. Usable for send/return of alway active pedals (in ex volume pedal)
See schematics. .
- IN Guitar or bass INPUT
TUNER Tuner output. Always on even in MUTE.
PEDALBOARD
leds show:
- 1-10 BLUE: loop 1 to 10
- S 1-4 RED switch on/off 1, 2, 3 AND 4 .
- MUTE orange MUTE on.
- BFR GREEN buffer on
OUT A e
OUT B YELLOW outputs A (LEFT) and B (RIGHT) ON
- P WHITE : PROGRAM FUNCTION ACTIVE
- L – BLUE. LOOP function active
- C ORANGE shows a control change function active
Buttons 1-10 got dual function: activation of single loop or recall of programs. While in programs mode button
allows to program the switches 1-to 4, the buffer, the A and B out and may recall as well up to 5 control changes
and MIDI functions.

Vinteck
V
-
10 CLIPPER
pag.6
Edizione 01 revisione0
WIRING EXAMPLES
Followings schematis are only examples. Nor to be inted as LOW !!! Personal choise in sound building
is the only real referement!
Ex 1. 8 effects in front, 2 effects in send/return. Mono.

Vinteck
V
-
10 CLIPPER
pag.7
Edizione 01 revisione0
Ex 2
8 effects in front, 2 stereo effects in Send return on 2 amps. Line insulator on amp 2. Midi management and
expressione MIDI pedal.

Vinteck
V
-
10 CLIPPER
pag.8
Edizione 01 revisione0
Ex 3
8 effects in front, 2 couple of effects in stereo in fronte of 2 amps. Line insulator on amp 2.
Volume pedal after distorsion pedals.

Vinteck
V
-
10 CLIPPER
pag.9
Edizione 01 revisione0
6- USE AND PROGRAMMING OF V-10 CLIPPER. MIDI MANAGEMENT
FUNCTIONS OF “MD” BUTTON
MD button
Make selection between LOOP and PROGRAM function of buttons 1 to 10
BLU LED “L” ON buttons 1 to 10 make direct activation of single loops
WHITE led ON button 1 to 10 recall programs
Other function:
While in programming mode MD button gives SAVE function, then close procedure.
Holding pressed MD with WHITE LED “P” on MIDI MAPPING function is activated.
Holding pressed MD with BLUE LED “L” on V10 goes in GLOBAL.
BUTTON “UP” and “DW” FUNCTIONS
UP BUTTON
With WHITE LED “P” ON increments the banks, from 0 to 11, if banks are active.
Other functions
In programming mode allows input in “control change assign to patch”
With BLUE LED “L” ON, holding pressed allows access to “BANK ACTIVATION” function.
DW BUTTON
With WHITE LED “P” ON decrements the banks, from 0 to 11, if banks are active.
Other functions
In programming mode allows input in “PATCH NAME ON DISPLAY”
MUTE Function
MUTE (silence oc pedalboard, with TUNER out Active) is activable pressing DW while in LOOP
MODE
MUTE is also assignable to any patch, if needed.

Vinteck
V
-
10 CLIPPER
pag.10
Edizione 01 revisione0
GLOBAL FUNCTION
GLOBAL allows predefinition of following operative parameters, as in following table.
But
ton
FUNCTION COMMAND
1
COMMAND 2 VALUE OUT
SAVE
DEF
A
ULT
1 MIDI in channel UP DW 0 – omni
1
-
16
MD 0
2
MIDI out canne,
MASTER
UP DW
1
-
16
MD
1
3
MIDI
numbering
0
-
127 / 1
-
128
UP DW
0
-
1
MD
1
4 External Tap Tempo
Control Change
UP DW 0-127 MD 80
5
Control Change assignament to
buttons 1 2 3 4 5
P1,P2,P3, P4,
P5
UP / DW
P
6
-
CC nr
0
-
120
MD
000
P
7
-
OUT channel
1
-
16
MD
1
P
8
-
CC value
0
-
127
MD
000
6 External expression pedal
Expression pedal calibration
Values assigament
P1,P 2, P3
UP, DW
P1- pedale value 0-255 MD 255-
255
P2
-
LOW limit
0
-
127
MD
000
P3
-
HIGH limit
0
-
127
MD
000
7
B
u
ffer ON / OFF global
UP, DW
P10
MD
OFF
8
9 Switch 1, 2, 3 e 4: latch, single
shot, dual shot
UP, DW
1,2,3,4
LATCH
SINGLE SHOT
DUAL SHOT
MD LAT
CH
10 BANKS activation UP, DW 1-10 ACTIVE
OFF
MD 1-on
GLOBAL FUNTION ENTER
With blue led “L” press and hold MD for 4 seconds
Display show GLOBAL
Press button corresponding to wanted function
1- MIDI input channel
Display show MIDI IN followed by a number from 00 to 16.
00 is OMNI, all channels ON.
Make selection with UP and DW (down).
Save and exit with MD
2- MIDI output channe
Display show MIDI OUT followed by a number from 1 to 16
Make selection with UP and DW (down).
Save and exit with MD
Nota: this selection is general, may be changed for any control change
Indice