Table of contents
1 General.................................................................................................................... 4
1.1 Copyright © VIPA GmbH ................................................................................. 4
1.2 About this manual............................................................................................. 5
1.3 Safety information............................................................................................. 6
2 Hardware description............................................................................................. 7
2.1 Safety information for users.............................................................................. 7
2.2 Properties......................................................................................................... 8
2.3 Structure........................................................................................................... 9
2.3.1 Overview........................................................................................................ 9
2.3.2 Interfaces..................................................................................................... 11
2.3.3 Memory management.................................................................................. 14
2.4 Dimensions..................................................................................................... 15
2.5 General data................................................................................................... 17
2.6 Technical data................................................................................................. 18
2.6.1 67S-PNL0-JB............................................................................................... 18
2.6.2 67S-PNL0-JX............................................................................................... 21
3 Deployment Panel PC.......................................................................................... 24
3.1 Installation...................................................................................................... 24
3.2 Installation of the CFast card.......................................................................... 25
3.3 Commissioning............................................................................................... 26
3.3.1 Firmware update.......................................................................................... 26
3.3.2 VIPA Startup-Manager................................................................................. 27
3.4 Connection to a PLC system.......................................................................... 30
3.5 Operating system Windows Embedded Standard 7....................................... 31
3.5.1 General........................................................................................................ 31
3.5.2 Structure...................................................................................................... 32
4 BIOS setup............................................................................................................ 37
4.1 Overview......................................................................................................... 37
4.2 Main................................................................................................................ 38
4.3 Advanced........................................................................................................ 39
4.4 Chipset........................................................................................................... 44
4.5 Boot................................................................................................................ 47
4.6 Security........................................................................................................... 48
4.7 Save and exit.................................................................................................. 49
5 Installation guidelines.......................................................................................... 51
5.1 Basic rules for the EMC-equitable assembly of installations.......................... 51
5.2 EMC-equitable assembly................................................................................ 54
5.3 EMC-equitable cabling................................................................................... 55
5.4 Special precautions providing high noise immunity........................................ 58
5.5 Checklist for the EMC-compliant installation of controllers............................. 59
VIPA HMI Table of contents
HB160 | PPC | 67S-PNL0 | en | 18-18 3

1 General
1.1 Copyright © VIPA GmbH
This document contains proprietary information of VIPA and is not to be disclosed or used
except in accordance with applicable agreements.
This material is protected by the copyright laws. It may not be reproduced, distributed, or
altered in any fashion by any entity (either internal or external to VIPA), except in accord-
ance with applicable agreements, contracts or licensing, without the express written con-
sent of VIPA and the business management owner of the material.
For permission to reproduce or distribute, please contact: VIPA, Gesellschaft für Visuali-
sierung und Prozessautomatisierung mbH Ohmstraße 4, D-91074 Herzogenaurach, Ger-
many
Tel.: +49 9132 744 -0
Fax.: +49 9132 744-1864
EMail: [email protected]
http://www.vipa.com
Every effort has been made to ensure that the information contained in
this document was complete and accurate at the time of publishing. Nev-
ertheless, the authors retain the right to modify the information.
This customer document describes all the hardware units and functions
known at the present time. Descriptions may be included for units which
are not present at the customer site. The exact scope of delivery is
described in the respective purchase contract.
Hereby, VIPA GmbH declares that the products and systems are in compliance with the
essential requirements and other relevant provisions. Conformity is indicated by the CE
marking affixed to the product.
For more information regarding CE marking and Declaration of Conformity (DoC), please
contact your local VIPA customer service organization.
VIPA, SLIO, System 100V, System 200V, System 300V, System 300S, System 400V,
System 500S and Commander Compact are registered trademarks of VIPA Gesellschaft
für Visualisierung und Prozessautomatisierung mbH.
SPEED7 is a registered trademark of profichip GmbH.
SIMATIC, STEP, SINEC, TIA Portal, S7-300 and S7-400 are registered trademarks of
Siemens AG.
Microsoft and Windows are registered trademarks of Microsoft Inc., USA.
Portable Document Format (PDF) and Postscript are registered trademarks of Adobe
Systems, Inc.
All other trademarks, logos and service or product marks specified herein are owned by
their respective companies.
Contact your local VIPA Customer Service Organization representative if you wish to
report errors or questions regarding the contents of this document. If you are unable to
locate a customer service centre, contact VIPA as follows:
All Rights Reserved
CE Conformity Declaration
Conformity Information
Trademarks
Information product sup-
port
VIPA HMI
General
Copyright © VIPA GmbH
HB160 | PPC | 67S-PNL0 | en | 18-18
4

VIPA GmbH, Ohmstraße 4, 91074 Herzogenaurach, Germany
Telefax: +49 9132 744-1204
EMail: [email protected]
Contact your local VIPA Customer Service Organization representative if you encounter
problems with the product or have questions regarding the product. If you are unable to
locate a customer service centre, contact VIPA as follows:
VIPA GmbH, Ohmstraße 4, 91074 Herzogenaurach, Germany
Tel.: +49 9132 744-1150 (Hotline)
EMail: [email protected]
1.2 About this manual
This manual describes the Panel PC 67S-PNL0-... from VIPA. It contains a description of
the structure, project engineering and deployment. This manual is relevant for:
Product Order number as of state:
HW FW BS
PPC021 ES 67S-PNL0-... 01 V1.0.6 WindowsÒ Embedded Standard 7
The manual is targeted at users who have a background in automation technology.
The manual consists of chapters. Every chapter provides a self-contained description of a
specific topic.
The following guides are available in the manual:
nAn overall table of contents at the beginning of the manual
nReferences with page numbers
The manual is available in:
nprinted form, on paper
nin electronic form as PDF-file (Adobe Acrobat Reader)
Important passages in the text are highlighted by following icons and headings:
DANGER!
Immediate or likely danger. Personal injury is possible.
CAUTION!
Damages to property is likely if these warnings are not heeded.
Technical support
Objective and contents
Target audience
Structure of the manual
Guide to the document
Availability
Icons Headings
VIPA HMI General
About this manual
HB160 | PPC | 67S-PNL0 | en | 18-18 5

Supplementary information and useful tips.
1.3 Safety information
The system is constructed and produced for:
ncommunication and process control
ngeneral control and automation tasks
nindustrial applications
noperation within the environmental conditions specified in the technical data
ninstallation into a cubicle
DANGER!
This device is not certified for applications in
–in explosive environments (EX-zone)
The manual must be available to all personnel in the
nproject design department
ninstallation department
ncommissioning
noperation
CAUTION!
The following conditions must be met before using or commis-
sioning the components described in this manual:
– Hardware modifications to the process control system should only be
carried out when the system has been disconnected from power!
–Installation and hardware modifications only by properly trained per-
sonnel.
– The national rules and regulations of the respective country must be
satisfied (installation, safety, EMC ...)
National rules and regulations apply to the disposal of the unit!
Applications conforming
with specifications
Documentation
Disposal
VIPA HMI
General
Safety information
HB160 | PPC | 67S-PNL0 | en | 18-18 6

2 Hardware description
2.1 Safety information for users
VIPA modules make use of highly integrated components in MOS-Technology. These
components are extremely sensitive to over-voltages that can occur during electrostatic
discharges. The following symbol is attached to modules that can be destroyed by elec-
trostatic discharges.
The Symbol is located on the module, the module rack or on packing material and it indi-
cates the presence of electrostatic sensitive equipment. It is possible that electrostatic
sensitive equipment is destroyed by energies and voltages that are far less than the
human threshold of perception. These voltages can occur where persons do not dis-
charge themselves before handling electrostatic sensitive modules and they can damage
components thereby, causing the module to become inoperable or unusable. Modules
that have been damaged by electrostatic discharges can fail after a temperature change,
mechanical shock or changes in the electrical load. Only the consequent implementation
of protection devices and meticulous attention to the applicable rules and regulations for
handling the respective equipment can prevent failures of electrostatic sensitive modules.
Modules must be shipped in the original packing material.
When you are conducting measurements on electrostatic sensitive modules you should
take the following precautions:
nFloating instruments must be discharged before use.
nInstruments must be grounded.
Modifying electrostatic sensitive modules you should only use soldering irons with
grounded tips.
CAUTION!
Personnel and instruments should be grounded when working on electro-
static sensitive modules.
Handling of electrostatic
sensitive modules
Shipping of modules
Measurements and altera-
tions on electrostatic sen-
sitive modules
VIPA HMI Hardware description
Safety information for users
HB160 | PPC | 67S-PNL0 | en | 18-18 7

2.2 Properties
The VIPA Panel PC is a combination of industrial PC with state of the art performance
features and a touch panel with ideal display capabilities. The Panel PC is a compact and
modular embedded PC based on WindowsÒ Embedded Standard 7 - WES7. Besides the
extensive WES7 functions the Panel PC offers varied communication possibilities.
nWindowsÒ Embedded Standard 7
nMovicon 11 Win Standard 7 (67S-PNL0-JB)
n21.5" 16:9 TFT panel 16.7 M color
nPCAP, multitouch
nDisplay resolution 1920 x 1080
nIntelÒ Atom Processor D2550, Dualcore, 1.86GHz, 1M L2 Cache
nWork memory: 2x 204Pin DDR3 SO-DIMM Socket, 2GB DDR3
nUser memory: 16GB SSD
nCFast slot
n2 RS232/RS422/RS485 (switchable), 4 USB-A-, 2 Ethernet interfaces, VGA port and
Audio out
nMetal case
nPassive cooling
nEasy mounting via integrated pivoted lever
nProtection class IP65 (frontal)
Order data
Type Order number Description
PPC021 ES 67S-PNL0-... 21.5'' TFT color, 2x RS232/RS422/RS485, 4x USB-A, 2x Ethernet
RJ45, VGA, Audio out
General
VIPA HMI
Hardware description
Properties
HB160 | PPC | 67S-PNL0 | en | 18-18 8

2.3 Structure
2.3.1 Overview
1 Slot for voltage supply (DC 12-30V)
2 VGA interface
3 Reset button
4 RS232/RS422/RS485 interface COM 2
5 RS232/RS422/RS485 interface COM 1
6 4x"Host"-USB-A interface
7 RJ45 jack for Ethernet communication LAN 2
8 RJ45 jack for Ethernet communication LAN 1
9 3.5mm Audio Line out
10 Power switch (pushbutton)
11 Slot for CFast storage media
12 Display with touch sensitive area (touch screen)
Front view
VIPA HMI Hardware description
Structure > Overview
HB160 | PPC | 67S-PNL0 | en | 18-18 9

1 Slot for voltage supply (DC 12-30V)
2 VGA interface
3 Reset button
4 RS232/RS422/RS485 interface COM 2
5 RS232/RS422/RS485 interface COM 1
6 4x"Host"-USB-A interface
7 RJ45 jack for Ethernet communication LAN 2
8 RJ45 jack for Ethernet communication LAN 1
9 3.5mm Audio Line out
Please make sure that the Panel PC always has to be supplied with
external voltage!
1 Slot for CFast storage media
2 Power switch (pushbutton)
The Panel PC starts automatically when the power supply is switched on.
But you can change the configuration in the BIOS setup so that the Panel
PC has to be switched off by the power switch.
Ä
‘Restore AC Power
Loss’ on page 46
After a Windows
Ò
‘Shut down’ the Panel PC can be switched on again
by means of the power switch at any time.
During operation the Panel PC switches to the sleep mode by briefly
pushing the power switch. By pushing the power switch again the sleep
mode is switched off.
Bottom view
Top view
VIPA HMI
Hardware description
Structure > Overview
HB160 | PPC | 67S-PNL0 | en | 18-18 10
Indice
Altri manuali VIPA Pannello touch

VIPA
VIPA PPC 67S-PNL0 Manuale utente

VIPA
VIPA TP 608C CAN Manuale utente

VIPA
VIPA TP 606C Manuale utente

VIPA
VIPA 608-1BC41 Manuale utente

VIPA
VIPA 606-3B1E0 Manuale utente

VIPA
VIPA 605-3B1F0 Manuale utente

VIPA
VIPA HMI 610-3B2I0 Manuale utente

VIPA
VIPA HMI TP 612C Manuale utente

VIPA
VIPA TP 610C Manuale utente

VIPA
VIPA TP 608C CAN Manuale utente

VIPA
VIPA 62M-JEE0 Manuale utente

VIPA
VIPA HMI Manuale utente

VIPA
VIPA TP 610C Manuale utente

VIPA
VIPA TP 608C CAN Manuale utente

VIPA
VIPA TP 605MQ-2 Manuale utente

VIPA
VIPA HMI 610-3B4I1 Manuale utente

VIPA
VIPA 606-3B2E0 Manuale utente

VIPA
VIPA TP 605CQ CAN-2 Manuale utente

VIPA
VIPA HMI 62E-MDC0 Manuale utente

VIPA
VIPA 610-1BC41 Manuale utente