Vitrum Scene Manuale del proprietario

HOME CONTROL
THINK SIMPLE
EN
INSTALLATION and OPERATION
Vitrum Scene Control Panel

DESCRIPTION
A Vitrum Scene differs from Dimmer and
On-Off devices for this reason: there
is no exit used for directly control a load.
It’s used for creating lighting scenarios in
your house: simply pressing a button, you
can switch on and off (in case of lamp
connected to a Vitrum dimmer you can
select the light level too) the lights of your
scenary.
.
INDEX
0. Before starting ................ 3
1. Electrical connections ........... 4
2. Positioning the glass decor panel . . 6
3. Vitrum is intelligent . . . . . . . . . . . . . 8
4. Advanced functions ........... 11
5. Factory Reset ................ 14
7. Supervision.................. 16
8. Compatibility ................ 17
9. Compliance with ec directives . . 17
MAIN TECHNICAL SPECIFICATIONS
. . 18

3
0. BEFORE STARTING
The Vitrum system that you have purchased is designed for connection to your existing
240V power supply circuit. Before commencing installation, ensure that the mains power
supply had been disconnected by setting the main switch on your electricity meter to
OFF
. Do not re-connect the power supply and start using Vitrum until all connections
have been correctly completed and the Vitrum unit has been inserted into the wall-
mounting box.
Vitrum must be installed by a professional electrician who is qualified to operate
on electrical power circuits in full compliance with all current safety legislation.
For each device, connect the power supply and the return wire from the actuators as
shown in the circuit diagrams printed on the rear of the boxes in the vicinity of the terminal
block. Refer exclusively to the circuit diagrams contained in this manual, especially if
connecting the system without an earth wire.
Carefully check that the wires and connectors are securely fastened. After
securing the unit to the wall-mounting box, temporarily use the plastic cover
for protection until the glass décor plate is fitted.
Do not install Vitrum in the vicinity of sources of heat or in conditions of high humidity.

4
1. ELECTRICAL CONNECTIONS
Electrical connections with neutral wire: connect the Live wire to the terminal marked
“L”, the Neutral wire to the terminal marked “N”:

5
IMPORTANT
After connecting, check that the wires are correctly positioned inside the wall-
mounting box. When securing Vitrum to the wall-mounting box, use the screws sup-
plied and note that the maximum torque to be used when tightening the screws in
the embedding box is 0.8 Nm. In addition, the surface of the wall for at least 2 cm
surrounding the embedding box MUST BE as flat and smooth as possible, and must not
have any rough patches and/or bumps that protrude more than 1 mm.
If the screws are not tightened with the torque specified, or if the embedding
box is installed on unsuitable surfaces, the correct operation of the device can-
not be guaranteed.
Think Simple Spa accepts no liability if the device is not correctly installed as described above.

6
2. POSITIONING THE GLASS DECOR PANEL
In order to refit the glass panel correctly, ensure that the four plastic tabs on the
panel are in perfect alignment with the anchor holes. When the glass panel tabs
are aligned with the holes, press the four corners of the glass panel evenly until it
is fully inserted into the wall-mounting box.
Anchor holes on electronic section

7
After fitting the glass panel, the buttons remain inoperative for about 10 seconds.
An acoustic signal sounds three times to indicate that the sensors have been
recalibrated, after which they resume normal operation. To remove the glass panel
from the wall-mounting box, gently lever the upper or lower edge away.
Anchor holes on décor panel

8
3. VITRUM IS INTELLIGENT
The product that you have purchased functions when included in a Z-Wave wireless net.
Thanks to “Z-Wave” Wireless technology, each Vitrum Wireless unit offers numerous
advantages if connected as part of a network: it is possible to associate multiple Vitrum
units, to construct scenarios, and to control lights using a remote control unit. If you connect
Vitrum into a pre-existing z-wave net working with third parts devices, please refer to
instruction and procedure of your remote control. Otherwise proceed as follows to include
Vitrum to your Home Wireless NETWORK:
Open the rear panel of the• HOME MASTER remote handset.
1A
B
C
D
2
3
4

9
Press and hold down• “INC” until the corresponding LED turns yellow, then
release the button
Place the HOME MASTER remote handset near the Vitrum unit to be included in•
the network. Touch any of the keys on Vitrum to include the unit in the home
wireless network.
Everytime a new device is included into the zwave net, you must include your Vitrum
scene again; during this operation, Vitrum scene will blink of magenta color for few
seconds: wait until it stop to proceed.

10
When all the Vitrum units have been added to the network, press the “INC”•
key again until the LED switches off. Now you will see that the illuminated rings
around the Vitrum touch keys no longer light red when changing from one
status to the next.
NOTE
A Vitrum unit cannot be added to the network if it has already been included
in a different network. In this case, it is necessary to perform the factory reset
procedure -> see Paragraph 7).