Back Flow Prevention: Where back flow prevention is required, install
our Back Flow Prevention Valve at the supply elbow hose connection
of the handpiece.
Any water seepage ex- the cartridge cavity opening can be stopped by retightening the large brass retaining nut.
If you have performance issues please check there are no flow restrictors between the hose and the handpiece, or
the hose and the shower elbow. Remove any restrictors with rubber washers.
Plumbers Note: Do not pressure test this mixer under static pressure.
TROUBLESHOOTING
1. Is the lever between 7 and 8 O’clock? When installed correctly the lever should be close to 7 O’clock position, at 38°C, delivering about 6L per minute,
where the relative hot/cold pressures are not greater than 10:1. We recommend installing the supplied Needle Valve when there is a greater than 10/1
ratio of cold to hot kPa (The needle valve should be about an 1/8th turn open), or if the hot/cold mix is temperamental.
2. If the lever is beyond 8 O’clock position, it is likely:
– One of the valve inserts has been removed from the hot/cold ports;
– The supply elbow has a restrictive bore (i.e. less than 10mm);
– The supply hose has a bore size less than 9.5mm;
– The handpiece is not a free-flow single function model
– The WELs restrictor hasn’t been removed.
– The Pressure reducing valve has not been readjusted (the feed valve on the LP Hot water cylinder should always be readjusted when installing a new
mixer, because the head pressure drops over time. To readjust the Feed Valve (Pressure reducing valve) – turn the adjuster screw clockwise until the first
drips appear from the relief pipe (protruding from the roof) or relief valve then back it o half-a-turn and re-secure the locking nut.
3. If the hot/cold mix is temperamental where the lever positon is within 7-8 O’clock position, either the hot or cold pressures will just require a slight tweak.
4. Check that the hot and cold supply lines have not been incorrectly plumbed in, i.e. such as the cold supply connected to the hot inlet and hot supply
connected to the cold inlet. This is especially bad for Unequal Low systems as the hot port on the shower mixer body can enlarge meaning that the valve
inserts will also need to be swapped.
5. *When using with Unequal Low systems,it needs to be remembered the requirement for a minimum of 450mm of straight outlet pipe, before any
bends.
WARRANTY
PLEASE CALL US BEFORE REMOVING TAPWARE OR UNDERTAKING ANY REPAIR WORK.
Please refer to our website for warranty information: www.vodaplumbingware.co.nz/warranty
In the unlikely event that this product fails during its warranty period, phone our Customer Service team
immediately on 0508 367 366 – as unauthorised removal of the product may void the warranty.
CARE AND MAINTENANCE
SHOULD NOT BE CLEANED WITH ACIDIC, CAUSTIC/ALKALINE, ABRASIVE OR CITRIC CLEANERS.
A so, damp cloth is recommended for cleaning (Not a Micro fibre cloth). Mild soap solutions can also be used on
occasion.
Voda Plumbingware (NZ) Ltd | Freephone: 0508 367 366 | 5 Hewlett Street, Port Whangarei 0110 | vodaplumbingware.co.nz
HOTsupply only
COLDsupplyonly
Min 45mm
Max60mm
Seal with silicon
if necessary
IMPORTANT:
450mm Minimum
Straight Distance*
115mm Faceplate
150mm Faceplate
**Min = Ø60mm
**Max = Ø700mm
90mm Faceplate
**Min = Ø60mm
**Max = Ø70mm
**Cut To Suit Faceplate