VWR Puranity TU3+ Manuale utente

Version: 1
Issued : February, 2016
INSTRUCTION MANUAL
VWR
®
PURANITY TU+
European Catalogue Number(s)
171-1231
171-1232
171-1233
171-1234
171-1235
171-1236
171-1237
171-1238
171-1239
Puranity TU3+
Puranity TU3 UV+
Puranity TU3 UV/UF+
Puranity TU6+
Puranity TU6 UV+
Puranity TU6 UV/UF+
Puranity TU12+
Puranity TU 12 UV+
Puranity TU 12 UV/UF+

Legal Address of manufacture
VWR International bvba
Researchpark Haasrode 2020
Geldenaaksebaan 464
B - 3001 euven
+ 32 16 385011
http://be.vwr.com
Country of origin
Sweden

VWR Puranity TU+ | iii
Technical Service
Web Resources
Visit the VWR website at www.vwr.com for:
Complete technical service contact information
Access to the VWR Online Catalogue, and information about accessories and related
products
Additional product information and special offers
Contact us
For information or technical assistance contact your local VWR representative or visit
www.vwr.com.
Warranty
VWR International
warrants that this product will be free from defects in material and workmanship for a
period of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair,
replace, or refund the purchase price of this product to the customer, provided it is returned during the
warranty period. This warranty does not apply if the product has been damaged by accident, abuse,
misuse, or misapplication, or from ordinary wear and tear. If the required maintenance and inspection
services are not performed according to the manuals and any local regulations, such warranty turns invalid,
except to the extent, the defect of the product is not due to such non-performance.
Items being returned must be insured by the customer against possible damage or loss. This
warranty shall be limited to the aforementioned remedies. IT IS EXPRESS Y AGREED THAT THIS
WARRANTY WI BE IN IEU OF A WARRANTIES OF FITNESS AND IN IEU OF THE WARRANTY
OF MERCHANTABI ITY.

iv
|
Puranity TU+ VWR
Explanatory notes on the operating instructions
EU Mark of Conformity
CAUTI N
Indicates a situation which, if not avoided, could result in damage to equipment or property.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious
injuries.
DANGER
Indicates a hazardous situation which, if not avoided, will result in death or serious injuries.
N TE!
Is used for applicational hints and useful information.
Risk of electric shock. Electrical work on the system is only to be carried out by qualified
personnel.
Protective conductor connection
Connect the power supply to an electrical socket with a protective connection.
Indicates a situation in which protective gloves or clothing must be worn.
Indicates a situation in which protective goggles must be worn.
Indicates a situation in which breathing protection must be used.

VWR Puranity TU+ | v
This information is valid for the system that is received.
For quick and correct service, please include the following information on all inquiries and
replacement parts orders which relate to your system:
The serial number (located on the back of the unit on the nameplate)
The catalog number
Compliance with local laws and regulations
The customer is responsible for applying for and obtaining the necessary regulatory approvals or
other authorisations necessary to run or use the Product in its local environment. VWR will not be
held liable for any related omission or for not obtaining the required approval or authorisation,
unless any refusal is due to a defect of the product.

vi
|
Puranity TU+ VWR

Table of Contents
Chapter 1 Transport and packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Examination on receipt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
Complaints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Packaging for return shipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2
Chapter 2 Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Chapter 3 Extend of delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Extend of delivery Puranity TU3+/6+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7
Available Puranity TU 3+/6+ systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
Extend of Delivery Puranity TU 12+ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8
Available storage tanks for Puranity TU 12+ system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
Available Puranity TU 12+ systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
Chapter 4 Intended use of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chapter 5 Technical specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Chapter 6 The installation area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Chapter 7 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Connections of the Puranity TU 3+/6+ system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-21
Connections of the Puranity TU 12+ system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-23
Connections of the pure water tank Puranity TU 12+. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-25
Bring your Puranity TU+ system into operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-26
Connecting an external tank to the Puranity TU 12+ system . . . . . . . . . . . . . . . . . . . . . . . .7-29
Illustration of drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-30
Wall mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-31
Mounting the power pack (voltage supply) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-32
Mounting the ball valve to the Puranity TU+ system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-34
Chapter 8 Flow chart. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Chapter 9 How the Puranity TU+ system functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Chapter 10 Initial start up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Putting the system into operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-39
Venting the 0.2 µm final filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-40
Chapter 11 perating elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Chapter 12 System control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-43
Mono/dual measurement mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-43
Setting the limiting value for conductivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-45

Setting the limiting value for temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-46
Error message and acoustic error signal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-47
Communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-48
Potential-free contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-48
Chapter 13 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Maintenance Intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-49
Replacing the ultrapure cartridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-50
Replacing the RO/pretreatment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-52
Cleaning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-53
Changing the ultrafilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-56
UV-reactor assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-58
Replacing the UV lamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-59
Replacing the 0.2 µm final filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-61
Autoclaving the 0.2 µm final filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-62
Chapter 14 Equipment disposal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Chapter 15 Trouble shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Chapter 16 Consumables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-67
Chapter 17 Terminal assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Chapter 18 Maintenance record . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Chapter 19 Your Distributor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
Chapter 20 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75

VWR Puranity TU+ | 1
Transport and packaging
Ultrapure water systems are carefully inspected and packed prior to shipping, but damage could
still possibly occur during transport. ifting and carrying the VWR Ultrapure Water System, e.g. to
the installation location, should be carried out by two people.
Examination on receipt
Check the completeness of the goods received against the packing list.
N TE!
Does the packaging show signs of damage? Inspect the system for damage.
Packaging
System

| Transport and packaging
2
|
Puranity TU+ VWR
Chapter 1
Complaints
Should damage have occurred to the goods during transport:
Immediately contact your delivery transport agency.
Save the complete packaging, including the cardboard box, for a possible inspection of them
and/or return shipment of the system.
Packaging for return shipment
If possible, use the original box and packaging material.
When these are no longer available, then:
Protect the system from shock by packing it in bubble wrap and/or packaging foam and a
strong cardboard box.
N TE!
nly a trained person should take the system out of operation.
Prior to send back a operated device, empty the water and dry the system and take out
the cartridges.
Pack the ultrapure cartridges into a bubble wrap and/or packaging foam and take it with
in into the package of the Ultrapure Water System.
Questo manuale è adatto per i seguenti modelli
8
Indice
Altri manuali VWR Sistema idrico
Manuali Sistema idrico popolari di altre marche

Spirotech
Spirotech SPIROVENT SUPERIOR S250 Manuale utente

Culligan
Culligan Aqua-Cleer Aqua-Cleer Advanced Drinking Water... Manuale utente

A.O. Smith
A.O. Smith Dura-Max AJH - 1000A - P Manuale utente

Microline
Microline T.F.C.-4 Manuale

Eureka Forbes
Eureka Forbes Aquaguard Select Manuale utente

Cetetherm
Cetetherm AquaEfficiency Manuale utente














