4G/SMS/Ethernet Contact ID Communicator
PSTN/4G Contact ID Protocol to SMS Alert & SIA IP Converter

Page 2 of 14 Ver 1.2 Date: 20170805
Table of Contents
1.
Introduction. .................................................................................................................................................... 3
2.
Specifications. ................................................................................................................................................. 3
3.
Features. .......................................................................................................................................................... 3
4.
Standard Package. ......................................................................................................................................... 4
5.
Overview of Main Panel. ............................................................................................................................... 4
6.
Indicator Lights. .............................................................................................................................................. 5
7.
Connection. ..................................................................................................................................................... 5
8.
Installations ..................................................................................................................................................... 5
8.1 Install the USB Driver on PC. ........................................................................................ 6
8.2. Install the USB Driver on PC. ....................................................................................... 6
8.3. Settings in PC Configurator. ......................................................................................... 6
8.3.1 The Menu Bar of the PC configurator. ........................................................................................... 7
8.3.2 GPRS data Parameter Setting........................................................................................................ 7
8.3.3 The Phone Numbers for Events Notification. ............................................................................... 8
8.3.4 Set the Password and PIN Code Verification. .............................................................................. 8
8.3.5 Set the OC Outputs Names ............................................................................................................ 8
8.3.6 Set the CMS Server IP address and Server Port. ....................................................................... 9
8.3.7 Set the Output pulse time and Ethernet parameter. .................................................................... 9
8.3.8 The other buttons in PC configurator. .......................................................................................... 10
8.3.9 Set the SMS Notification Contents. .............................................................................................. 10
8.4.0 Engineer Debug for GPRS Data Transmission. ......................................................................... 11
9.
SMS Commands. ......................................................................................................................................... 11
10. Warranty. ............................................................................................................................................................. 13
Safe Startup
Do not use GSM unit when using GSM equipment is prohibited or might bring disturbance or danger.
Interference
This handbook has been designed as a guide to the installation and operation of GSM Communicator.
Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained
with other products. We recommend that the advice of a registered electrician be sought before any Installation work commences.
Cornick Co., Ltd, its employees and distributors, accept no liability for any loss or damage including consequential damage due to
reliance on any material contained in this handbook.
Cornick Co., Ltd, its employees and distributors, accept no liability for GSM Network upgrading or SIM Card upgrading due to the
technology specifications contained in this handbook.
All wireless equipment might interfere network signals of GSM unit and influence its performance.

Page 3 of 14 Ver 1.2 Date: 20170805
1. Introduction
The GSM/3G/4G Communicator WGSMSC is specially designed for existing Watchguard alarm systems.
The GSM/3G/4G Communicator WGSMSC can transfer the Alert Message from your PSTN Contact ID (SIA
DC-05) Control panel into SIA DC-09 protocol over Ethernet/GPRS network and SMS notification. It can
change alert notifications from traditional PSTN alert to Ethernet/wireless alert (SIA standard DC-09
requirements).
(
Notice:
‘WGSMSC’ will be written in the following contents below instead of ‘GSM/3G/4G LTE
Communicator WGSMSC’
)
2. Specifications
Signal Frequency
Communication Ways
Message Transmission Protocols
Outputs
Configuration
Power Supply
Used Current
Workplace
Backup battery
Exterior dimension
GSM850 / 900 / 1800 / 1900 MHz (3G/4G module optional) ;
For example: Customer only need to replace the module for
upgrading WGSMSC from 3G to 4G
Ethernet & TCP/IP via GPRS
SIA DC-09-2007 or SIA DC-09-2012 (WGSMSC)
SIA DC-05 (PSTN Control Panel)
OUT1, OUT2 ,OC type, commutates voltage of up to 30 V
and direct current of up to 1 A
via USB port or SMS commands
DC 9V ---24 V
10 ---30 mA (on standby),
up to 70 mA (while sending data)
Temperature from -10C to +50C,
Relative humidity up to 80 % when +20 C
900mAH
105 mm * 88 mm * 30 mm (W*D*H)
3. Features
Easy programmed by PC configuration, compatible with most alarm panels.
Modular system, upgrade 3G/4G only need to replace the module.
Supports transferring data by PSTN Ethernet or GPRS, SMS ( no phone
call ),
Supports 2 different CMS centers (IP addresses or DNS server).

Page 4 of 14 Ver 1.2 Date: 20170805
SMS notification when the connection with the CMS center is failed (3 trial times).
When PSTN network failed, it will send the alert message to the center by Ethernet/GPRS network,
When the PSTN network good, then it will not use GPRS network etc. for transferring alert message,
5 users to receive SMS notification on Alarm, Supervision, Trouble, By pass, Test, GPRS fail, DC loss,
SMS commands to check the device version, IMEI code, GSM signal,
2 OC outputs which could be controlled by SMS commands, output pulse time can be set.
Support firmware upgrading via USB.
Supports PIN code verification in PC configurator.
Remote configuration by SMS commands.
Backup rechargeable battery, with DC power failure SMS alert.
4. Standard Package
Main Panel x 1 piece,
CD (User Manual & PC Configurator) x 1 piece
5. Overview of Main Panel
GSM Antenna
GSM Signal
Power Signal
GPRS Signal
USB Port for PC Configurator.
Power Supply
Ethernet Port
Ethernet

Page 5 of 14 Ver 1.2 Date: 20170805
T1: Connect with the ‘TLP’ in PSTN control panel
R1: Connect with the ‘RING’ in PSTN control panel
T2: Connect with the Land Line
R2: Connect with the Land Line
(Notice: No connection means the control panel will transmit the message only via GPRS.)
OUT1: 1
st
Outputs, OC type.
COM: General terminal.
OUT2: 2
nd
Outputs, OC type.
6. Indicator Lights
[RED]: GMS Indicator, blinking every 0.5s = registering the network, when the GSM signal is
normal, it will blink every 1s.
[RED]: Power Supply Indicator, blinking every 1s = the battery is on charge, ON means the
battery is in full charge, OFF means disconnected from the external power adapter.
[RED]: GPRS Data Indicator, it will blink every 1s when WGSMSC is transferring GPRS data.
[RED]: Ethernet indicator, it will keep blinking when WGSMSC is transferring GPRS
data; ON means Ethernet connect to the server successfully.
7. Connection

Page 6 of 14 Ver 1.2 Date: 20170805
8.1 Install the USB Driver on PC.
1)
Screw on the GSM antenna.
2)
Open the cover on the back the WGSMSC to find the SIM card holder, and insert the SIM card as below:
3) Turn on the power supply and switch WGSMSC on, and check the GSM Signal Indicator light to
confirm the SIM card in WGSMSC is working . Check lights details in 【6. The Indicator Lights】.
8.2. Install the USB Driver on PC.
1) Download and install the latest USB Driver according to your PC operation system.
2) Connect the WGSMSC to the Computer via USB cable,
3) Find the USB Serial Port as picture below. (This COM port number will be used in PC configurator).
8.3. Settings in PC Configurator.
Choose the USB Serial Port according to 【8.2. Install the USB Driver on PC.】, and click
open Com ,
it
will come to the
Basic Information
window as below:
Notice:
when the settings in current window is done, please click Save Settings
to complete the configuration.
Firmware
Upgrading
Button
Switch
8. Installations
Notice:
There are 2 methods for changing settings: PC configuration & SMS commands. Install the USB Driver
before using the PC confirgurator.

Page 7 of 14 Ver 1.2 Date: 20170805
Connected successful Status
8.3.1 The Menu Bar of the PC configurator.
Loading Profile [Alt + L]: Load the setting profile that you have saved before
Save the Profile [Alt + S]: Save the settings to the local
Recovery Factory Default [Alt + R]: Reset the WGSMSC device back to the factory
About [Alt + A]: The information about the WGSMSC
Exit [Alt + E]: Exit the PC configurator.
8.3.2 GPRS data Parameter Setting.
Notice: The example above is only for reference, please contact your local GSM operator for the settings accordingly. If
the local GSM Operator does not use APN anymore, please ignore the settings in this section.
everywhere
secure
secure
For EXAMPLE:

Page 8 of 14 Ver 1.2 Date: 20170805
8.3.3 The Phone Numbers for Events Notification.
Tel No. 1 – No. 5 The phone numbers for the SMS notification.
Alarm
Ademco® Contact ID Protocol Events Codes.
Supervision
Trouble
Open
ByPass
Test
GPRS Fail The GPRS message transmission failure notification from WGSMSC .
The external DC Power Loss notification from WGSMSC
DC Loss
Notice:
1) Tick the phone numbers in the list that will receive the SMS notification when the event occur.
2) Only for SMS notification, no voice communication.
3)
18676734714
is the phone number only for example. If the WGSMSC can’t work, please add your country code in
front of the phone number.
8.3.4 Set the Password and PIN Code Verification.
8.3.5 Set the OC Outputs Names
Notice:
The max characters for the Output Name is 40, these names will be displayed in the SMS notifications.
The name of the 1
st
Output, default: DO1
The name of the 2
nd
Output, default: DO2
Alarm Host PSTN Protocol: SIA DC-05.
GPRS Protocol: SIA DC-09-2007/2012.
Notice:
The ‘’WGSMSC Password’’ is the password in
the setting of
【
9. The SMS Commands.
】
. The
"Account number."can set to replace the PSTN
panel account when upload via GPRS.

Page 9 of 14 Ver 1.2 Date: 20170805
8.3.6 Set the CMS Server IP address and Server Port.
8.3.7 Set the Output pulse time and Ethernet parameter.
Output Pulse Time 0~9999S
Ethernet Parameter
Default "0",means getting IP and DNS automatically
GPRS
Module
(optional)
a.1) With GPRS module, if not connect the Ethernet, device will send SMS: "
Ethernet connection failed, please check the wired network!"
2) With GPRS module, if the Ethernet connect the server failed or server not response, will SMS"
ETH Connect Failure
"
At this time, the alert will transfer the data via GPRS; But if Ethernet connect successfully and
server response well, then not transfer the data via GPRS.
b. Without GPRS module, only transfer data via Ethernet.
Notice:
The alert messages will be transmitted
to Server 2 (backup) once Server 1
failed after both of them are set.

Page 10 of 14 Ver 1.2 Date: 20170805
8.3.8 The other buttons in PC configurator.
open Com
Open the USB serial Com Port.
Close Com
When displayed, it means successful connection.
Read Version Info
Read the device model, IMEI Code, Version.
Read settings
Read the existed setting data in the WGSMSC.
Save Settings
Click this button to complete the current settings.
Delete Settings
Delete all the setting data in WGSMSC.
Clear Display
Clear the words displayed in the current windows (The existed settings will not be cleared).
Clear Received Data
Clear the data WGSMSC have received in the current window.
Clear Sent Data
Clear the data WGSMSC have send in the current window.
Stop Debug
Stop the debug.
Notice: There are three different windows in PC configurator:
Basic Information
,
SMS Message
,
GPRS Debug
.
Please click the
Save Settings
when the setting data in the current windows is completed.
8.3.9 Set the SMS Notification Contents.
Partition Please set it according to your PSTN control panel. ( 2 digits, from 0 - 9, B – F )
Zone
(64 zones)
Please set it according to your PSTN control panel. ( 3 digits, from 0 - 9, B – F )
SMS Text Message
(Max 59 characters)
The SMS alert content when the zone in the PSTN control panel is triggered.
Notice: if this part is not set, the SMS Alert Message will be in SIA DC-05 code, not understandable.