Foamstream M600 –User manual –English (EU) –16/05/2018 - ISSUE 3
7
Figure 5 - Bleed screen of the PLC
If starting when water tank level is below water filter
level perform either of the following:
1. Fill water tank to higher level than water filter
2. If unable to fill water tank select scenario below and
follow the instructions
✓Water filter full, no air in system - Machine will start
like normal.
✓Water filter full, air in system - Perform an additional
air bleed.
✓Water filter empty - Manually fill water filter and then
replace, then perform additional air bleeds until no
faults/errors appear on the screen (“No flow at outlet”
“Release Trigger”) then perform one additional air
bleed to ensure system is free of air.
✓Wait until the purge is completed. A new screen will
appear, represented in Figure 6.
Figure 6 - Start screen of the PLC
✓Press START, the button turns green and the screen
represented on Figure 7 will appear.