Wenglor IR 00 Series Manuale utente

IRxx00x
Inductive Ring Sensor
Operating Instructions
Translation of the original operating instructions
Subject to change without notice
Available as PDF file only
Version 1.0.0
As of: 7/04/2023
www.wenglor.com
EN

2Table of Contents
Table of Content
1. General ........................................................................................................................................................4
1.1 Information Concerning these Instructions ..........................................................................................4
1.2 Explanations of Symbols......................................................................................................................4
1.3 Limitation of Liability.............................................................................................................................5
1.4 Copyrights............................................................................................................................................5
2. For Your Safety ..........................................................................................................................................6
2.1 Use for Intended Purpose....................................................................................................................6
2.2 Use for Other than the Intended Purpose............................................................................................6
2.3 Personnel Qualifications ......................................................................................................................6
2.4 Modification of Products.......................................................................................................................6
2.5 General Safety Precautions.................................................................................................................7
2.6 Approvals and Protection Class...........................................................................................................7
3. Technical Data ............................................................................................................................................8
3.1 General Data........................................................................................................................................8
3.2 Housing Dimensions............................................................................................................................9
3.3 Connection Diagram ..........................................................................................................................10
3.4 Complementary Products ..................................................................................................................11
3.5 Control Panel .....................................................................................................................................11
3.6 Scope of Delivery...............................................................................................................................11
4. Transport and Storage .............................................................................................................................12
4.1 Transport............................................................................................................................................12
4.2 Storage ..............................................................................................................................................12
5. Installation and Electrical Connection....................................................................................................12
5.1 Installation..........................................................................................................................................12
5.1.1 Installation Using the Soft Binder ...........................................................................................13
5.1.2 Other Installation Options.......................................................................................................14
5.1.3 Installation Instructions ..........................................................................................................14
5.1.4 Smallest Recognizable Object ...............................................................................................15
5.2 Electrical Connection .........................................................................................................................15
5.3 Troubleshooting .................................................................................................................................15
6. Functions Overview..................................................................................................................................16
6.1 Function Description ..........................................................................................................................16
6.1.1 Starting Up the Product As Supplied......................................................................................16
6.1.2 Starting Up the Product with User-Defined Settings ..............................................................16
6.2 LED Symbols .....................................................................................................................................18

3Inductive Sensors
7. Setup via IO-Link .....................................................................................................................................19
8. Maintenance Instructions ........................................................................................................................20
9. Proper Disposal ........................................................................................................................................20
10. Appendix ...................................................................................................................................................20
10.1 Revision History .................................................................................................................................20
10.2 Declarations of Conformity.................................................................................................................20

4General
1. General
1.1 Information Concerning these Instructions
• These instructions apply to products designated IRxx00x.
• These instructions make it possible to use the product safely and efficiently.
• These instructions are an integral part of the product and must be kept on hand for the entire duration of its
service life.
• Local accident prevention regulations and national work safety regulations must be complied with as well.
• The product is subject to further technical development, and thus the information contained in these oper-
ating instructions may also be subject to change. The current version can be found at www.wenglor.com in
the product’s separate download area.
NOTE!
The operating instructions must be read carefully before using the product and must be kept
on hand for later reference!
1.2 Explanations of Symbols
• Safety precautions and warnings are emphasized by means of symbols and signal words.
• Safe use of the product is only possible if these safety precautions and warnings are adhered to.
• The safety precautions and warnings are laid out in accordance with the following principle:
SIGNAL WORD
Type and source of danger!
Possible consequences in the event that the hazard is disregarded.
• Measures for averting the hazard
The meanings of the signal words, as well as the scope of the associated hazards, are listed below:
DANGER!
This signal word indicates a hazard with a high degree of risk which, if not avoided, results
in death or severe injury.
WARNING!
This signal word indicates a hazard with a medium degree of risk which, if not avoided, may
result in death or severe injury.
CAUTION!
This signal word indicates a hazard with a low degree of risk which, if not avoided, may
result in minor or moderate injury.

5Inductive Sensors
ATTENTION!
This word draws attention to a potentially hazardous situation which, if not avoided, may
result in property damage.
NOTE!
A note draws attention to useful tips and suggestions, as well as information regarding
efficient, error-free use.
1.3 Limitation of Liability
• The product has been developed in consideration of the current state-of-the-art technology, as well as
applicable standards and guidelines. Subject to change without notice. A valid declaration of conformity can
be found at www.wenglor.com in the product’s separate download area.
• wenglor sensoric elektronische Geräte GmbH (hereinafter referred to as "wenglor") excludes all liability in
the event of:
• Non-compliance with the instructions
• Use of the product for purposes other than those intended
• Use by untrained personnel
• Use of unapproved replacement parts
• Unapproved modification of products
• These operating instructions do not include any guarantees from wenglor with regard to the described pro-
cedures or specific product characteristics.
• wenglor assumes no liability for printing errors or other inaccuracies contained in these operating instruc-
tions unless wenglor was verifiably aware of such errors at the point in time at which the operating instruc-
tions were prepared.
1.4 Copyrights
• The contents of these instructions are protected by copyright law.
• All rights are reserved by wenglor.
• Commercial reproduction or any other commercial use of the provided content and information, in particular
graphics and images, is not permitted without previous written consent from wenglor.

6For Your Safety
2. For Your Safety
2.1 Use for Intended Purpose
This wenglor product is intended for use in accordance with the following functional principle.
This sensor is used to detect metal objects.
An LC circuit is set up around the ring-shaped opening. The electromagnetic field generated by this circuit is
influenced when metal (for instance, steel, aluminum, or brass) approaches.
The target group is manufacturers of screwdriving and feeding technology.
2.2 Use for Other than the Intended Purpose
• Not a safety component in accordance with 2006/42/EC (Machinery Directive).
• The product is not suitable for use in potentially explosive atmospheres.
• The product may be used only with accessories supplied or approved by wenglor, or in combination with
approved products. A list of approved accessories and combination products can be found at
www.wenglor.com on the product detail page.
DANGER!
Risk of personal injury or property damage in case of use for other than the intended
purpose!
Use for other than the intended purpose may lead to hazardous situations.
• Observe instructions regarding use for intended purpose.
2.3 Personnel Qualifications
• Suitable technical training is a prerequisite.
• In-house electronics training is required.
• Trained personnel who use the product must have (permanent) access to the operating instruc-
tions.
DANGER!
Risk of personal injury or property damage in case of incorrect initial start-up and
maintenance!
Personal injury and damage to equipment may occur.
• Adequate training and qualification of personnel
2.4 Modification of Products
DANGER!
Risk of personal injury or property damage if the product is modied.
Personal injury and damage to equipment may occur. Noncompliance may result in loss of
the CE mark and voiding of the warranty.
• Modification of the product is not permitted

7Inductive Sensors
2.5 General Safety Precautions
NOTE!
• These instructions are an integral part of the product and must be kept on hand for the
entire duration of its service life.
• In the event of possible changes, the current version of the operating instructions can be
found at www.wenglor.com in the product’s separate download area.
• Read the operating instructions carefully before using the product.
• Protect the sensor against contamination and mechanical influences.
2.6 Approvals and Protection Class

8Technical Data
3. Technical Data
3.1 General Data
IR2D001 IR3D001
Inductive Data
Inside Diameter 10.2 mm 15.1 mm
Functional Principle Dynamic
Smallest Recognizable Object (∅) 2 mm * 2.5 mm*
Correction Factors for V2A Stainless
Steel/CuZn/Al 1/1/1
Electrical Data
Supply Voltage 10…30 V DC
Current Consumption
(Operating Voltage = 24 V) < 20 mA
Object Speed < 50 m/s
Response Time < 100 µs
Ready-State Delay 1 s
Switching Output Voltage Drop 1.5 V
Temperature Range 0...60°C
Short-Circuit Proof Yes
Reverse Polarity and Overload-Proof Yes
Switching Output Switching Current 100 mA
Interface IO-Link V1.1
Mechanical Data
Connection Type M8×1, 4-pin
Setting Method Potentiometer/IO-Link
Hanger Opening/Closing Cycles Max. 100
Degree of Protection IP 54
Adjustable Parameters
Output
PNP
Push-Pull
NPN
Circuit
NO
NC/NO
NC
Pulse Length 5…200 ms
Other Parameters Sensitivity
Alternative frequency
Output Function
PNP
NPN
NC
NO
Technical Safety Data
MTTFd (EN ISO 13849-1) 1019, 99
* Relates to a steel ball

9Inductive Sensors
3.2 Housing Dimensions
IR2x00x
IR3x00x

10 Technical Data
3.3 Connection Diagram
Applies to sensors designated IRxx001
Legend
Wire Colors according to IEC 60757
Platinum measuring resistor
not connected
Test Input
Test Input inverted
Trigger Input
Ground for the Trigger Input
Analog Output
Ground for the Analog Output
Block Discharge
Valve Output
Valve Control Output +
Valve Control Output 0 V
Synchronization
Ground for the Synchronization
Receiver-Line
Emitter-Line
Grounding
Switching Distance Reduction
Ethernet Receive Path
Ethernet Send Path
Interfaces-Bus A(+)/B(–)
Emitted Light disengageable
Magnet activation
Input confirmation
Contactor Monitoring
Black
Brown
Red
Orange
Yellow
Green
Blue
Violet
Grey
White
Pink
Green/Yellow
Supply Voltage +
Supply Voltage 0 V
Supply Voltage (AC Voltage)
Switching Output (NO)
Switching Output (NC)
Contamination/Error Output (NO)
Contamination/Error Output (NC)
Input (analog or digital)
Teach Input
Time Delay (activation)
Shielding
Interface Receive Path
Interface Send Path
Ready
Ground
Clock
Output/Input programmable
Power over Ethernet
Safety Input
Safety Output
Signal Output
Ethernet Gigabit bidirect. data line (A-D)
Encoder 0-pulse 0-0 (TTL)
Encoder A/A (TTL)
Encoder B/B (TTL)
Encoder A
Encoder B
Digital output MIN
Digital output MAX
Digital output OK
Synchronization In
Synchronization OUT
Brightness output
Maintenance
reserved
PT
PT
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali Wenglor Sensore di sicurezza

Wenglor
Wenglor SG4-I Manuale utente

Wenglor
Wenglor U2GT Series Manuale utente

Wenglor
Wenglor B60 Series Manuale utente

Wenglor
Wenglor Y1TA Series Manuale utente

Wenglor
Wenglor IR3F001 Manuale utente

Wenglor
Wenglor IR2D002 Manuale utente

Wenglor
Wenglor IR2D001 Manuale utente

Wenglor
Wenglor PNBC Series Manuale utente

Wenglor
Wenglor I08G003 Manuale utente

Wenglor
Wenglor OPT2139 Manuale utente