ELI CT£ICAL REQUIREMENTS
1. A three-wire or four-wire single phase 120/240 volt 60
Hz AC only electrical supply (or three-wire or four-wire
120/208 volt if specified on nameplate) is required on a
separate 30 ampere circuit, fused on both sides of the line
(time-delay fuse or circuit breaker is recommended). Do
NOT fuse neutral.
2. THE DRYER MUST BE CONNECTED WITH COPPER
WIRE ONLY. Aluminum wire must not be used to avoid
potentially unsatisfactory connections.
3. Local codes may permit the use of a flexible type 30
ampere U L listed power supply cord (pigtail) with no
smaller than No. 10 copper wire to match three-wire
receptacle of NEMA Type 10-30R shown in the following
figure. A suitable strain relief must be provided at the
point the power supply cord enters the appliance.
IMPORTANT:
OBSERVE ALL GOVERNING CODES AND ORDINANCES
5. CAUTION: For mobile home installations, the appliance
wiring must be revised. The appliance frame must not be
connected to the neutral terminal, but must be connected
to the ground wire (green) of the power supply cord.
If four-wire receptacle of NEMA Type 14-30R is used (see
figure below), a matching UL listed power supply cord
(pigtail) for mobile homes must be used. This cord con-
tains four No. 10 copper conductors with spade or ring
terminals on dryer end terminating in a NEMA type
14-30P plug on supply end. The fourth (grounding) con-
ductor must be identified by a green cover and the
neutral conductor by a white cover. Cord should be Type
SRD or SRDT, with strain relief and be at least 4 feet long.
The power supply cord and strain relief are not provided
with the dryer.
3WIRE RECEPTACLE
WARNING: Do not plug the power supply cord 4WIRERI:CEPTACL_
I
(pigtail) into a live wall receptacle before connectingefusb_d
the pigtail to the dryer terminal block
• The appliance may be connected directly to the
isconnect (or circuit breaker) box through fl "
armored or non-metallic sheathed copper cable. Allow two
or three feet of slack in the line between the wall and the
appliance so that it can be moved if servicing is ever
necessary. A suitable strain relief must be provided at each RECEPTACLE
114-30R)
end of the power supply cord (at the appliance and at the RECEPTACLE
junction box). Wire sizes (COPPER WIRE ONLY) and 11o-3om
connections must conform with the rating of the appliance Typical 30 ampere receptacles for use where local codes
(30amperes). Do not use an extension cord. permit use of flexible power supply cord (pigtail),
3