White Mountain LS18SRAO-1 Guida rapida

INSTALLATION INSTRUCTIONS
AND OWNER'S MANUAL
LOG SET FOR UNVENTED
GAS LOG HEATER
OR
VENTED DECORATIVE APPLIANCE
MODELS
LS18SRAO-1
LS24SRAO-1
LS30SRAO-1
WARNING: If not installed, operated and maintained in ac-
cordancewiththemanufacturer'sinstructions,thisproduct
couldexposeyoutosubstancesinfuelorfromfuelcombus-
tion which can cause death or serious illness.
Log sets comply with ANSI Z21.11.2 Unvented Heaters and
alsocomplywithANSIZ21.60DecorativeVentedAppliances
for Solid Fuel Burning Fireplaces. State or local codes may
RQO\DOORZRSHUDWLRQRIORJVHWVLQDYHQWHGFRQ¿JXUDWLRQ
Check your state or local codes.
WARNINGS
± 'RQRWVWRUHRUXVHJDVROLQHRURWKHUÀDPPDEOH
vapors
and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
'RQRWWU\WROLJKWDQ\DSSOLDQFH
'RQRWWRXFKDQ\HOHFWULFDOVZLWFKGRQRWXVHDQ\SKRQH
in your building.
,PPHGLDWHO\ FDOO \RXU JDV VXSSOLHU IURP QHLJKERU¶V
SKRQH)ROORZWKHJDVVXSSOLHU¶VLQVWUXFWLRQV
,I\RXFDQQRWUHDFK\RXUJDVVXSSOLHUFDOOWKH¿UHGH-
partment.
± ,QVWDOODWLRQDQGVHUYLFHPXVWEHSHUIRUPHGE\DTXDOL¿HG
installer, service agency or the gas supplier.
If the information in this manual is not followed exactly,
D¿UHRUH[SORVLRQPD\UHVXOWFDXVLQJSURSHUW\GDPDJH
personal injury or loss of life.
The White Mountain Log Collection
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
STACKED AGED OAK
GAS-FIRED
Page 1

30583-0-0612Page 2
TABLE OF CONTENTS
IMPORTANT INSTALLATION GUIDELINES............................................................3
GENERAL INFORMATION......................................................................................3
REQUIREMENTS FOR CANADA............................................................................4
LOG IDENTIFICATION ............................................................................................5
LOG PLACEMENT..............................................................................................6-14
EMBER PLACEMENT - ALL BURNERS................................................................15
PLACEMENT OF GLOWING EMBERS LS18SRAO-1.....................................16-17
PLACEMENT OF GLOWING EMBERS LS24SRAO-1.....................................18-19
PLACEMENT OF GLOWING EMBERS LS30SRAO-1.....................................20-21
PARTS LIST & PARTS VIEW.................................................................................22
MASTER PARTS DISTRIBUTOR LIST..................................................................23
HOW TO ORDER REPAIR PARTS........................................................................23
SECTION PAGE

30583-0-0612 Page 3
Proper Log Placement
Log placement is critical to proper burner performance. Logs must
be correctly positioned onto the burner. The photos in this manual
showtheproperpinnedpositionforlogsonthisset.Ownersneedto
beshownproperlogplacementandinstructednottomovethelogs.
/RJVPXVW¿W¿UPO\RQWRWKHEXUQHUZKHQSRVLWLRQHGDVVKRZQLQ
the photos. Misformed logs or logs with sloppy pin holes must be
replaced.
Proper Placement of Rock Wool and Decorative Lava Rock
Rock wool can be added to burners for a glowing ember effect.
It must be positioned only on the front portion of the burner. The
photos in this manual show the proper placement of rock wool.
Decorative lava rock or small wood pieces should never be placed
RQWKHEXUQHU7KHVHLWHPVDUHRQO\IRUSODFHPHQWRQWKHÀRRURI
WKH¿UHSODFHRU¿UHER[
3URSHU3ULPDU\$LUÀRZLQWR%XUQHU
)RU SURSHU EXUQHU RSHUDWLRQ DQG ÀDPH DSSHDUDQFH WKH ÀRZ RI
SULPDU\DLULQWRWKHYHQWXULWXEHORFDWHGRQWKHUHDURIWKHEXUQHU
PXVWQRWEHUHGXFHG7KLVÀRZRIDLULVUHGXFHGLIGLUWOLQWRURWKHU
obstructions build-up around or inside the venturi. Any obstruction
LQWKHYHQWXULWXEHDUHDPXVWEHUHPRYHG7KHÀRZRIDLULQWRWKH
YHQWXULLVDOVRUHGXFHGLIWKHJDVRUL¿FHLVQ¶WFHQWHUHGLQWKHYHQWXUL
inlet and/or is not aligned with the venturi.Any misalignment of the
EXUQHURUL¿FHPD\EHFRUUHFWHGE\EHQGLQJWKHVKXWWHUFDSKROGLQJ
WKHRUL¿FHWRWKHLQOHWRIWKHYHQWXULWXEH
Ceiling Fans, Portable Fans or Logs Installed Near Cold Air
Returns
&HLOLQJ IDQV RU RVFLOODWLQJ ÀRRU W\SH IDQV QHHG WR EH PRQLWRUHG
during the operation of vent-free logs. If the air blows directly into
WKHÀDPHFDXVLQJLWWRLPSLQJHRQWKHORJVHWRU¿UHER[LWVKRXOGEH
turned off or redirected. Ceiling fans could be reversed to possibly
HOLPLQDWHÀDPHLPSLQJHPHQWDQGWKHÀRRUIDQFRXOGEHUHGLUHFWHG
8SRQLQVWDOODWLRQEHDZDUHRIDQ\FROGDLUUHWXUQVRUYHQWVLQWKH
SUR[LPLW\RIWKHORJVHW$Q\GUDIWFUHDWHGDURXQGDYHQWIUHHORJ
VHWFDQFDXVHWKHÀDPHWRLPSLQJHRQWKHORJDQGFUHDWHDVRRWLQJ
situation.
WARNING: 'RQRWDOORZ IDQVWREORZ GLUHFWO\LQWR WKH ¿UHSODFH
$YRLGDQ\GUDIWVWKDWDOWHUEXUQHUÀDPHSDWWHUQV
WARNING: 'RQRWXVHDEORZHULQVHUWKHDWH[FKDQJHULQVHUWRU
other accessory not approved for use with this heater.
Candles
Avoid the use of scented or decorative candles while the log set is
in operation. Candles produce a residue in the air that creates a
soot like substance. Burning candles while the log set is operating
PDJQL¿HVWKHSUREOHP,WVKRXOGEHQRWHGWKDWFDQGOHVLQJHQHUDO
producesoot.Theamountoftimeburnedandthequantityofcandles
burned will determine the amount of soot produced and deposited.
Make Owners Aware of Proper Log Set Operation
Properly installed and properly maintained log sets do not deposit
VRRWRQWKHORJV,IXVHUVVHHVRRWDSSHDURQDORJFDOOIRUVHUYLFH
Do not continue to operate the log set.
Sunken Fireplace
,I LQVWDOOLQJ WKLV XQLW LQWR D VXQNHQ ¿UHSODFH \RX PXVW UDLVH WKH
ÀRRUWRLQVXUHDGHTXDWHDLUÀRZDQGJXDUGDJDLQVWVRRWLQJ5DLVH
¿UHSODFHÀRRUXVLQJDQRQFRPEXVWLEOHPDWHULDOZKLFKLVVHFXUH
Glass Doors
Make sure that glass doors are open during all operations of the
logset.Theopeningoftheglassdoorframeshouldbethedimension
XVHGIRUWKHPLQLPXPIURQWRSHQLQJRIWKH¿UHER[
Woodburning Fireplaces
7KHLQWHULRURIWKH¿UHER[DQGWKHFKLPQH\VKRXOGEHFOHDQHGDQG
free of all creosote before installing a gas burning log set. Creosote
will soften when heated and can drop on the logset causing odors
and possibly sooting.
WARNING: %HIRUHLQVWDOOLQJLQDVROLGIXHOEXUQLQJ¿UHSODFHWKH
FKLPQH\ÀXHDQG¿UHER[PXVWEHFOHDQHGRIVRRWFUHRVRWHDVKHV
DQGORRVHSDLQWE\DTXDOL¿HGFKLPQH\FOHDQHU
4XDOL¿HG,QVWDOOLQJ$JHQF\
,QVWDOODWLRQ DQG UHSODFHPHQW RI JDV SLSLQJ JDV XWLOL]DWLRQ
equipment or accessories and repair and servicing of equip-
PHQWVKDOOEHSHUIRUPHGRQO\E\DTXDOL¿HGDJHQF\7KHWHUP
TXDOL¿HGDJHQF\PHDQVDQ\LQGLYLGXDO¿UPFRUSRUDWLRQ
or company that either in person or through a representa-
WLYHLVHQJDJHGLQDQGLVUHVSRQVLEOHIRUDWKHLQVWDOODWLRQ
WHVWLQJRUUHSODFHPHQWRIJDVSLSLQJRUEWKHFRQQHFWLRQ
LQVWDOODWLRQWHVWLQJUHSDLURUVHUYLFLQJRIHTXLSPHQWWKDWLV
H[SHULHQFHGLQVXFKZRUNWKDWLVIDPLOLDUZLWKDOOSUHFDXWLRQV
UHTXLUHGDQGWKDWKDVFRPSOLHGZLWKDOOWKHUHTXLUHPHQWVRI
the authority having jurisdiction.
7KH LQVWDOODWLRQ PXVW FRQIRUP ZLWK ORFDO FRGHV RU LQ WKH
DEVHQFHRIORFDOFRGHVZLWKWKHNational Fuel Gas Code,
ANSI Z223.1/NFPA54.*
*Available from the American National Standards Institute, Inc. 11 West
42nd St., New York, N.Y. 10018.
State of Massachusetts: The installation must be made
E\DOLFHQVHGSOXPEHURUJDV¿WWHULQWKH&RPPRQZHDOWK
of Massachusetts.
6HOOHUVRIXQYHQWHGSURSDQHRUQDWXUDOJDV¿UHGVXSSOH-
mental room heaters shall provide to each purchaser a
copy of 527 CMR 30 upon sale of the unit.
IMPORTANT INSTALLATION GUIDELINES
GENERAL INFORMATION

30583-0-0612Page 4
REQUIREMENTS FOR CANADA
This unit cannot EH LQVWDOOHG LQ D 819(17(' DSSOLFDWLRQ WKLV
unit can only be installed as a VENTED application with these
requirements.
IMPORTANT SAFETY INFORMATION
This unit complies with ANSI Z21.60 and CGA 2.26 Decorative
Gas Appliances For Installation In Solid Fuel Burning Fireplaces.
'RQRWEXUQZRRGRUVROLGIXHOVLQD¿UHSODFHZKHUHDGHFRUDWLYH
gas log set is installed. This appliance is for installation only in
DVROLGIXHOEXUQLQJ¿UHSODFHPDVRQU\¿UHSODFHRUPDQXIDFWXUHG
¿UHSODFH
Warning: $Q\PRGL¿FDWLRQWRWKLV JDVORJVHWRUWR FRQWUROVFDQ
be dangerous. Improper installation or use of the gas log set can
FDXVHVHULRXVLQMXU\RUGHDWKIURP¿UHEXUQVH[SORVLRQRUFDUERQ
PRQR[LGHSRLVRQLQJ
3OHDVHIROORZDOOORFDOFRGHVUHJDUGLQJ LQVWDOODWLRQFRPEXV-
tion and ventilation air or in the absence of local codes follow
WKH1DWLRQDO)XHO*DV&RGH$16,=86LQVWDOODWLRQRU
&$1&*$%,QVWDOODWLRQ&RGH&DQDGDLQVWDOODWLRQ
3URSHULQVWDOODWLRQEXUQHUSDQORFDWLRQDQGORJSODFHPHQWLV
important to achieve optimum look and performance of your
gas log set. The logs have been designed for easy location
and placement on the grate and must be followed for proper
operation.
3. Do not operate this log set with glass doors in the closed po-
VLWLRQ$¿UHSODFH VFUHHQPXVWEHLQSODFHZKHQWKH ORJVHW
is burning. Adequate combustion air must be provided for
SURSHUYHQWLQJ$OOÀDPHVVKRXOGJRXSDQGRXWWKHWRSRIWKH
¿UHER[LQWRWKHÀXHYHQW,IDQ\ÀDPHVÀRDWRUFXUOIRUZDUGLQWR
WKHURRPGR QRW RSHUDWHDSSOLDQFH&KHFN IRU DQ RSHQÀXH
and adequate combustion air into the room. A damper clamp
mustEHLQVWDOOHGRQWKH¿UHER[GDPSHUWRPDLQWDLQDQRSHQ
ÀXHYHQW FRQGLWLRQ 5HIHUWR SDJH¿UHSODFH RZQHUVPDQXDO
INSTALLING DAMPER CLAMP section.
4. Young children must be carefully supervised when they are in
the same room as the gas log while in operation. Do not place
VWRFNLQJVFORWKLQJRUDQ\ÀDPPDEOHPDWHULDODERYHRUQHDU
WKH¿UHSODFH
5. Do not substitute or use materials other than those supplied
for use with the log set.
6. Also refer to IMPORTANT SAFETY INFORMATION in the
¿UHSODFH2ZQHUV0DQXDO
:$51,1* '2 127 23(5$7( 7+,6 *$6 /2* 6(7 :,7+
GLASS DOORS CLOSED
&ORWKLQJRURWKHUÀDPPDEOHPDWHULDOVKRXOGQRWEHSODFHGRQ
or near the appliance.
'RQRWSODFHWUDVKRURWKHUDUWLFOHVRQWKHORJVHWGXULQJRS-
eration.
'XULQJPDQXIDFWXULQJIDEULFDWLQJDQGVKLSSLQJYDULRXVFRP-
SRQHQWVRIWKLVDSSOLDQFHDUHWUHDWHGZLWKFHUWDLQRLOV¿OPVRU
bonding agents. These bonding agents are not harmful but
may produce annoying smoke and smells as they are burned
off during initial operation of the appliance. This is a normal
temporary occurrence.Awindow should be opened during the
initial bake out period.
.HHSEXUQHUDQGFRQWUROFRPSDUWPHQWFOHDQ
WARNING: %HIRUHLQVWDOOLQJLQDVROLGIXHOEXUQLQJ¿UHSODFH
WKHFKLPQH\ÀXHDQG¿UHER[PXVWEHFOHDQHGRIVRRWFUHR-
VRWHDVKHVDQGORRVHSDLQWE\DTXDOL¿HGFKLPQH\FOHDQHU
,QVWDOODWLRQDQGUHSDLUVKRXOGEHGRQHE\DTXDOL¿HGVHUYLFH
person. The appliance should be inspected before use and
DWOHDVWDQQXDOO\E\DTXDOL¿HGVHUYLFHSHUVRQ0RUHIUHTXHQW
FOHDQLQJPD\EHUHTXLUHGGXHWRH[FHVVLYHOLQWIURPFDUSHWLQJ
EHGGLQJPDWHULDOVHWF,WLVLPSHUDWLYHWKDWFRQWURO FRPSDUW-
PHQWVEXUQHUVDQGFLUFXODWLQJDLUSDVVDJHZD\VRIWKHDSSOL-
ance be kept clean.
Do notSXWDQ\WKLQJDURXQGWKH¿UHSODFHWKDWZLOOREVWUXFWWKH
ÀRZRIYHQWLODWLRQDLU
Do keep the appliance area clear and free from combustible
PDWHULDOJDVROLQHDQGRWKHUÀDPPDEOHYDSRUVDQGOLTXLGV
$\HDUO\H[DPLQDWLRQ DQGFOHDQLQJ RI WKHYHQWLQJ V\VWHPRI
WKHVROLGIXHOEXUQLQJ¿UHSODFHPXVWEHSHUIRUPHGE\DTXDOL-
¿HGDJHQF\
Do make a periodic visual check of pilot and burners. Clean
and replace damaged parts.
Do not use this appliance if any part has been under water.
,PPHGLDWHO\FDOODTXDOL¿HGVHUYLFHWHFKQLFLDQWRLQVSHFWWKH
appliance and to replace any part of the control system and
any gas control which has been under water.
1HYHUEXUQVROLGIXHOVLQ¿UHSODFHZKHUHDJDVORJVHWLVLQ-
stalled.
7KLVXQLWFRPSOLHVZLWK$16,='HFRUDWLYH9HQWHG$SSOL-
ances for Solid Fuel Burning Fireplaces. State or local codes
PD\RQO\DOORZRSHUDWLRQRIWKLVDSSOLDQFHLQDYHQWHGFRQ¿JX-
ration. Check your state or local codes.

30583-0-0612 Page 5
LOG IDENTIFICATION

30583-0-0612Page 6
%HIRUH\RXEHJLQ'RQRWKDQGOHWKHVHORJVZLWK\RXUEDUHKDQGV$OZD\VZHDUJORYHVWRSUHYHQWVNLQLUULWDWLRQ$IWHUKDQGOLQJ
ORJVZDVK\RXUKDQGVJHQWO\ZLWKVRDSDQGZDWHU
All Logs
The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if
WKHORJVDUHQRWSURSHUO\DQG¿UPO\SRVLWLRQHGLQWKHDSSOLDQFH
Refer to Figure 1 for the following warning.
Warning:)DLOXUHWRSRVLWLRQWKHSDUWVLQDFFRUGDQFHZLWKWKLVGLDJUDPRUIDLOXUHWRXVHRQO\SDUWVVSHFL¿FDOO\DSSURYHG
with this appliance may result in property damage or personal injury.
Log Placement
LS(18, 24, 30)SRAO Logs
Figure 1
The following WARNING applies when log set is installed
onto an unvented gas burner assembly.
WARNING: This appliance is equipped for (natural or
propane) gas. Field conversion is not permitted.
LOG PLACEMENT
Attention: Referto Page 22 Parts ListandParts Viewtoorder logs
for your appropriate model number.
Apply loose material (glowing embers) per appropriate Installation
,QVWUXFWLRQVDQG2ZQHUV0DQXDO5HSODFHPHQWRIORRVHPDWHULDO
JORZLQJHPEHUVPXVWEHSXUFKDVHGIURP(PSLUH&RPIRUW6\VWHPV
,QF$SSOLFDWLRQ RI H[FHVV ORRVH PDWHULDO JORZLQJ HPEHUV PD\
adverselyaffectperformance of theheater.WARNING:Allpreviously
applied loose material must be removed prior to reapplication.
Replacement Loose Material (glowing embers) Part Number
LS18SRAO 15999
LS24SRAO 15970
LS30SRAO 15970

30583-0-0612 Page 7
TOP VIEW
FRONT VIEW
1. Place Back Ember Log (A) between the rear log support shelf and the main burner pan. The left side of the Back Ember Log will
set on the venturi shield.
LOG PLACEMENT

30583-0-0612Page 8
TOP VIEW
FRONT VIEW
2. Place the Back Right Log (B) so that it sets on Back Ember Log (A) and the main burner pan. The back of the Back Right Log will
rest against the rear log support shelf.
LOG PLACEMENT

30583-0-0612 Page 9
TOP VIEW
FRONT VIEW
3ODFHWKH%DFN/HIW/RJ&RQWKHOHIWVLGHRIWKHEXUQHUSDQ7KHULJKWVLGHRIWKH%DFN/HIW/RJ&¿WVLQWRWKHFXWRXWRQWKH
Back Ember Log (A).
LOG PLACEMENT

30583-0-0612Page 10
TOP VIEW
FRONT VIEW
4. Place the Front Left Log (D) onto the two front left pins on the burner pan.
LOG PLACEMENT
Altri manuali per LS18SRAO-1
1
Questo manuale è adatto per i seguenti modelli
2
Indice
Altri manuali White Mountain Camino da interno