Win4NET WinTera-1000 Manuale utente

WinTera
WinTera
WinTera-
-
-1000
1000
1000
STORAGE BOX
STORAGE BOX
STORAGE BOX
Manual
Manual
Manual

2
1. Storage box Setup
1-1 Front configuration
1-2 Back configuration
1-3 HDD Assembly
1-4 Cable connection
2.DIP SWITCH Setting
2-1 SCSI ID Setting
2-2 Terminator IC ON/OFF Setting
3. SCSI BIOS Setting
3-1 ARC-29160 SCSI BIOS Setting
3-2 AEC-67160 SCSI BIOS Setting
3-3 LSI - 21040 SCSI BIOS Setting
4. HDD Partition
5. Caution
INDEX
3
3
4
5
6
7
8
9
12
16
19
23

3
1-1. Front Configuration
1. Storage box Setup
1-2. Back Configuration
abcde
ac
b
a. HDD Fixing bolt
b. HDD LED
c. HDD Safety lock key
a. Power input ( AC 220 )
b. SCSI External input port
c. DIP SWITCH
d. SCSI External output port
e. ON/OFF SWITCH

4
1-3 HDD Assembly
1. Storage box Setup
First, the safety lock –key (A) turns
to set OFF, and screw the handle
volts (B&C) all the way to left off.
Next, pull the handle (D) out, the
whole HDD case will be separated.
Connect the 4 lines-connector (B)
and the 40 lines-connector (A) to a
HDD with care according to the arrow
direction.
( When you connect HDD, should set
jumper setting to ‘Cable select’.)
A
B
Make sure that 2 connectors are
connected to the HDD in the right
place.
B
DA
C
OFF
ON

5
1-3 HDD Assembly
1. Storage box Setup
Screw down tightly on the back side
of the HDD case.
Make sure that 4 holes are tightened
with bolts like the picture.
1-4 Cable Connection
Connect the cable between SCSI Card
on the back of DVR and a storage box.
Connect the cable between Input port
on the back of storage box and DVR.

6
2. DIP SWITCH SETTING
You can set 7 storage boxes maximum. Each storage box has two ‘SCSI’s which have own SCSI ID
number with DIP SWITCH.
One ‘SCSI ID 0’ has 4 pins (from 1 to 4), and the other ‘SCSI ID 1’ has also 4 pins (from 7 to 10).
Each ID is granted from SCSI host adapter in order. (from 0 to 7)
(ref> DIP SWITCH setting table in next page)
•SCSI ID ‘7’ can’t be used in because SCSI host adapter holds the number.
•There shouldn’t be same code (array).
Example) When using ‘SCSI ID 0’ and ‘SCSI ID 1’,
Pin # 1 2 3 4 Pin # 7 8 9 10
OFF OFF OFF OFF ON OFF OFF OFF

7
2. DIP SWITCH SETTING
2-1 DIP SWITCH Setting ( except Terminator IC Setting )
* Caution!
- Do not change DIP switch setting while storage boxes are working.
(To change the DIP switch setting, you have to turn off both DVR and storage boxes.)
- Do not connect SCSI cable to the SCSI output port of last storage box.
- If you change the DIP switch setting while working, the stored data will be gone or operating
system won’t work properly.
Ref>
If you want to set 7 storage boxes, each storage box has to be set like pictures as next page.
⑦ Dip Switch Setting
(When 7 storage boxes are connected to DVR, the seventh
storage box DIP set like picture on the right. Other boxes set
same way of the above.)
⑥ Dip Switch Setting
(When 6 storage boxes are connected to DVR, the sixth
storage box DIP set like picture on the right. Other boxes set
same way of the above.)
⑤ Dip Switch Setting
(When 5 storage boxes are connected to DVR, the fifth storage
box DIP set like picture on the right. Other boxes set same way
of the above.)
④ Dip Switch Setting
(When 4 storage boxes are connected to DVR,
the forth storage box DIP set like picture on the right. Other
boxes set same way of the above.)
③ Dip Switch Setting
(When 3 storage boxes are connected to DVR, set the first and
second box like picture ①, ②, and set the third box like picture
on the right.)
② Dip Switch Setting
(When 2 storage boxes are connected to DVR,
set the first box like picture ① and the second box like picture
on the right.)
① Dip Switch Setting
(When 1 storage box is connected to DVR, set the DIP switch
like picture on the right.)

8
2. DIP SWITCH SETTING
2-2 Terminator IC ON/OFF Setting
Terminator OFFTerminator ON
Condition
Pin # 5~6 OFFPin # 5~6 ON
Terminator IC ON/OFF is related to the DIP Switch setting that a SCSI host adapter finds the final
port which is connected to SCSI. Therefore, the terminal IC setting should be ON in the last
connected storage box among them.
(While using 3 storage boxes, if the terminal IC is ON both the second storage box and third storage
box, the third storage box will be malfunction or working improperly.)
Caution! : 1) Do not change DIP switch setting while storage boxes are working.
2) You have to turn off both DVR and storage box to change the DIP switch setting.

9
3. SCSI BIOS Setting
The most stable SCSI host adapters in a storage box are ‘ARC-29160’, ‘AEC-67160’, ’LSI-21040’.
See each CMOS setup below.
3-1 ARC 29160 SCSI BIOS setup
1. First, tern on a storage box.
10 seconds later, turn on DVR system,
then press [Ctrl] and [A] key on your
keyboard.
2. Select 29160 A at slot xx xx:xx:xx’.
3. Select ‘SCSI Disk Utilities’.
4. Make sure that all HDDs are set in the
system after HDD SCANING.
(You can check the capacity of each HDD
if you select a IDX.)

10
3. SCSI BIOS setting
5. To format, select each IDX.
Then, press ‘Enter’key.
6. The system will show this message to make
sure of format.
7. Press ‘Yes’to start format.
8. This message will come out during process.
9. This message will come out after it finishes
formatting.
Indice