Welcome! 4
Distributor/Installer contact information: 4
Product Overview 5
Document Scope 6
Renewable Energy Incentives 6
Safety Information 7
SolarMill Siting 8
Electrical Use Cases 10
What To Expect / Troubleshooting 11
SolarMill Specications 12
Limited Warranty 13

WindStream Technologies
4User GuideV2.01 Rev 11.3.13
Draft
Welcome!
Dear Customer,
Thank you for your purchase, and congratulations on becoming a SolarMill®owner!
We are excited that you have chosen to purchase WindStream’s renewable, hybrid energy generation
system. This manual will provide a basic overview of the product, available product congurations,
siting, installation, and operation of your SolarMill. Please read through this manual to ensure the
best possible performance and results from your installation. Technical assistance will be provided
via our customer service team. Please email us info@windstream-inc.com if you need any assistance.
Thank you for your purchase, and congratulations on becoming a SolarMill owner!
Sincerely,
Team Windstream
Installers, please write down the Serial Number(s) installed and service contact information in this booklet
and give to the customer. The Serial Number is located on the underside of the frame in the base of the unit.
SolarMill Serial Number(s)
Serial number(s) Installed by Commissioning
date
Distributor/Installer contact information:

WindStream Technologies
5User Guide V2.01 Rev 11.3.13
Draft
Product Overview
WindStream Technologies has created the SolarMill, a low-cost, highly ecient means of harnessing
both the sunlight on your site and the wind energy available from the turbulent winds present at low
altitude in both urban and rural environments.
The SolarMill is a modular, renewable energy system designed for both on and o grid applications.
This system will provide you with the lowest possible up front and operating costs, leading to a fast
return on your investment. The SolarMill utilizes 3 low-prole (one meter tall) Vertical Axis Wind
Turbines (VAWTs) mounted on a single base to collect wind power. The unique mounting geometry
allows for various solar panel congurations. The system is completely modular, allowing the system
to be daisy-chained to maximize total energy production in the simplest possible circuit.
SolarMills are highly ecient and produce power from wind speeds as low as four and a half (4.5) mph.
The company’s patented platform is a cost-eective and highly ecient distributed energy solution
currently unmatched in the marketplace. SolarMills are designed to supplement your energy needs,
reduce your energy costs and lower your overall environmental impact.
SM2-3P Conguration

WindStream Technologies
6User GuideV2.01 Rev 11.3.13
Draft
Document Scope
This manual provides an operation overview of the SolarMill in the following congurations:
• SM1-1P
• SM1-2P
• SM2-3P
• SM2-5P
• SM2-6P
Please keep this manual in a convenient place for future reference.
Target Group
This manual is for the end user, and contains important information regarding siting, use cases,
and visual inspection of the SolarMill unit. Installation and maintenance is to be performed by an
authorized distributor or their approved professional installers.
Renewable Energy Incentives
To support and encourage the deployment of renewable energy many governments and local utilities
oer a range of incentive programs. Your authorized WindStream distributor can help you to identify
and understand the programs and requirements you may be eligible for in your local area.
In the USA www.dsireusa.org provides a resource for researching Federal state and Local
incentive programs

WindStream Technologies
7User Guide V2.01 Rev 11.3.13
Draft
Safety Information
WARNING: Hazardous voltages, currents, or other conditions that could cause serious bodily injury or
death exist in the equipment or may be associated with its use.
Fast moving parts. Do not install this device in a location accessible to children and/or pets.
ONLY qualied personnel such as a WindStream Technologies’ employee, Authorized installer, licensed
contractor, or WindStream certied engineer should install the TurboMill or system of TurboMills.
The installation must be installed following the guidelines established by state and local regulations.
Consult a local electrical contractor, the local planning and zoning oce and local Electric Utility for
details and regulations. This manual is not intended to be used for the installation of this product but
to serve as an overview of the Turbomill, it’s functionality, hook-up and maintenance. The SolarMill
Technical Guide is required to properly install this product.
Once installed, use caution when approaching the device. The rotating turbines can present a serious
threat that can cause injury, even at low speeds.
WARNING: Never touch the rotating turbines.
WARNING: Never try to stop the turbines by hand.
Warranty related
The warranty and safety are dependent upon the proper installation of the product.
Installations not performed by qualied personnel will not be covered under WindStream
Technologies’limited warranty .
Turbines must not be allowed to turn until the low voltage bus is connected to charged batteries.
Turbines should be secured if the voltage drops below 30 VDC to avoid damage to the electronic
controller.

WindStream Technologies
8User GuideV2.01 Rev 11.3.13
Draft
SolarMill Siting
Siting of a SolarMill requires knowledge of the prevailing wind, an eye toward sun exposure, and an
assessment of the architecture available for mounting the units. Talk with a distributor, or see our
siting tools at www.windstream-inc.com for help with siting.
Prevailing winds
Most locations have a large proportion of their available wind power coming
from a single direction, (or sometimes 2 opposite directions). This is termed
the prevailing wind direction. The SolarMill turbines are omnidirectional, but
the row of turbines does result in some directionality. The line of SolarMills
should optimally be set up within 45 degrees of perpendicular to the
prevailing wind direction. Ultimately, the aerodynamics of the architectures
dictates positioning choices.
Architecture aerodynamics
The TurboMill is designed specically to mount directly to the roof
of a building or other structure. Consideration must be given to
the geometry of the roof structures and obstacles surrounding the
installation. Placing the turbines in a location where trees and other
structures would block the prevailing winds should be avoided.
An ideal siting location for a building mounted turbine is on a
building that is taller than the surrounding buildings and natural
obstructions both upwind and downwind. This will minimize the
eect of the surroundings on the wind ow eects immediately
above the roof.
A location at the peak of
a pitched roof or on the
windward edge of a at
rooftop is optimal as the wind there is accelerated. Other
locations on the roof, as the gure shows, have only small
wind velocities and high turbulence. Following these siting
guidelines will help to minimize avoidable energy losses for
building-mounted wind systems.
Sun Exposure
Solar panels need to be placed where they get sun exposure throughout the day. Shading for any
portion of the day will automatically eliminate power produced during that period.
In terms of direction, xed-angle solar installations are usually optimized when they face due
south in the northern hemisphere, and due north in the southern hemisphere. Furthermore, when
balanced for winter/summer exposure, panels are tilted up at the same angle as the latitude of the
100%
80%
60%
Expected power with wind
at suboptimal angles
The higher
the better
Downwind
eects
Upwind
eects

WindStream Technologies
9User Guide V2.01 Rev 11.3.13
Draft
location. However, deviations from optimal solar panel direction only result in very modest reduction
in power produced, allowing the units the exibility to follow the architecture when needed. For
more information on siting, see the siting resources on www.windstream-inc.com, or speak with a
distributor.
Installation Overview
The SolarMill is designed to provide considerable exibility in it’s mounting congurations. Generally
rooftops will fall into two categories: Flat and pitched. In both cases, the product generates signicant
tipping forces in high winds, so the installation must be strong enough to withstand both considerable
tensile forces and compressive forces. This often requires adding members below the units to spread
the loads. Windstream distributors can provide these as well as any leg extension kits needed to
position the units properly. The resulting structure can be connected directly to the structure of the
building, or if it is preferred to not penetrate the roof surface and the roof is suciently strong, the
structure can be freestanding, and ballasted.
All congurations require installation by distributor approved technicians, and involvement with
permitting bodies where localities require. Discuss mounting options with your distributor.

WindStream Technologies
10 User GuideV2.01 Rev 11.3.13
Draft
Electrical Use Cases
The SolarMill unit outputs DC power and that power is used to charge to a set of (4) 12V deep cycle
lead acid batteries. After the batteries, the customer has two choices on how to use this available
energy.
Grid tied
In this conguration, the bank of batteries
is connected to a grid tie inverter which
connects to the user’s electrical panel*.
This inverter pushes power back to the
grid eciently when the batteries become
fully charged. Check with your distributor
for WindStream approved inverter models
compatible with this type of connection.
*Grid connected systems may require
application and agreement with the local
power utility.
O-grid storage, with DC or AC loads
The batteries can be used to supply power to electrical
devices in o grid settings. This electrical energy can
power DC powered devices through a voltage converter
(if necessary), or can power AC devices through a
WindStream approved non-grid tie inverter**. It is
important to stress that if loads are not continuously
discharging the batteries, it will likely result in wasted
energy producing potential. A full charge cycle on the
battery can occur in a short amount of time. When
the batteries are fully charged, the system will cease
energy production to protect the batteries.
**Non-grid-tie inverters are not intended to push
power to the grid.
+
+
+
+
To other
SolarMill
strings
To other
SolarMill
strings
Grid tie
inverter
30A DC
Circuit
Breakers Main
Electrical
Panel
+
+
+
+
To other
SolarMill
strings
To other
SolarMill
strings
Non-Grid tie
inverter
30A DC
Circuit
Breakers
AC Loads
DC-DC Converter
12 VDC Loads
Grid-tied application
O-Grid application
Questo manuale è adatto per i seguenti modelli
4
Indice