Setting i
. .
9l
2°
JiIif
Anti-seizing pump
protection
Cycle block
~
Control unit IFunction IOperation
The heating program selector enables you to choose four operating modes:
Summer mode(central heating off)onlyDHWheating;frost protectionfor
the centralheatingsystemisensured.Integralanti-seizingpumpprotection.
Winter mode;inwintermode,the boilerheatsthe heatingwater temperature
to the value set at the heating water thermostat. Accordingto the pump
operatingmode,the circulationpumpoperatesconstantly(factorysetti1'19)
or only parallelto the burner control with/without run-on period.
Select this setting .!!iTwhen connecting control accessories.
Emissionstest mode:
Theemissionstest modeisactivated byrotating theprogramselectorinto
position i. A dot illuminates between the heating water temperature
indicationonthe LCDdisplay,whilstthe system isin emissionstest mode.
The program selector returns automatically to winter mode when it is
released.Afteremissionstest modehas been activated,the boilerheats to
the temperature set at the heatingwater thermostat without modulation
orto the maximumheating water temperature adjustedvia parameterno.
8. Any previouscycle blockwill be cancelled.The red dot between the
heating water temperature indication extinguishes when emissionstest
modeends.Inconjunctionwith DRT/ DWT/ DWTM/ DWTK,the emissions
test symbolwillbe transferred to the function display.Activationonlyon
the boiler.
°, DHWtemperature selection
When gas-fired condensing boilers are combinedwith a DHWcylinder,
setting1-9 correspondstoa cylindertemperatureof15-70°c.
°,
Heating water temperature selection
Thesetting range 1-9 correspondsto a heating water temperature of
20-75 (85)°C.Thesetting on the heating water thermostat willbecome
ineffectivewhen the system is used in conjunction with a digital room
thermostat or a weather-compensated controller.
Pressure di~play
Thisindicatesthe water pressurein the heating system.Innormal
operation,the water pressureshould be between 1.5-2.5bar.
Insummer mode, the circulator pump operates for approx. 30 seconds after
a maximum idle period of 24 hours.
Aburnerstart-up delayisintegrated to avoidfrequent burnerstarts during
the heating mode.Thecycleblockcan be adjusted from0-30 minutes.
7
~
Program selector
Setting
or .:=u
11\
Setting m-