Table 2
SPECIFICA
nONS
HEATING FLOW
28mm
COPPER
TUBE
HEATING RETURN
28mm
COPPER
TUBE
SAFETY VALVE
22mm
COPPER
TUBE
COLD
FEED
22mm
COPPER
TUBE
COLD WATER
MAINS
IN
15mm
COMPRESSION -SUPPLIED
DOMESTIC WATER OUT
22mm
COPPER
TUBE
GAS INLET
22mm
COPPER
TUBE
HEIGHT
860mm
(33.9in)
WIDTH
550mm
(21.6inl
DEPTH
600mm
(23.6in)
WEIGHT 95kg (2101b)
empty-
147kg (3241b) full
PRIMARY CAPACITY 48 litres (10.6 gal)
*MAXIMUM
STATIC HEAD
25m
(81ft.)
*MINIMUM
STATIC HEAD 1000mm (39in)
CIRCULATING PUMP
Grundfos
15-60
EXPANSION VESSEL 12
litres
charged
0.5
bar
OUTPUT
TO
HEATING
MAXIMUM
23.4kW (80,000 Btu/h)
OUTPUT
TO
DOMESTIC HOT WATER 23.4kW (80,000 Btu/h)
CH
CONTROL
THERMOSTAT-
MAX.
TEMPERATURE
Nominally
82°C
(180°F)
DOMESTIC HOT WATER FLOW
RATE
(35°C
RISE)
Nominally
9.6
litres/min
+
15%
(2.1
gal/min)
MAXIMUM
DOMESTIC HOT WATER FLOW RATE
Nominally
15
litres/min
(3.3
gal/min)
±15%
*
Appliance
static
heads
are
measured
from
the top
of
the
casing
to
the
highest
point
of
the
system
(See
Fig_s.
24.
and
25)
Table 3
HORIZONTAL VERTICAL
FLUE
DETAILS-
See Notes
Below
REAR FLUE PRIMARY FLUE
WALL OR
CEILING-
HOLE DIAMETER FOR AIR DUCT 125mm (Sin) 125mm (Sin)
WALL HOLE DIAMETER FOR SEALING RING 150mm (6in)
MINIMUM FLUE
LENGTH-
STANDARD FLUE KIT 100mm (4in) 1557mm (61.3in)
MAXIMUM FLUE
LENGTH-
STANDARD FLUE KIT 1
OOOmm
(39in) 2000mm (73in)
FLUE LENGTHS WITH EXTENSION KIT 1
001
to 2000mm
2001
to
3000mm
(39
to
73in) (79
to
118in)
If
a
flue
extension
is
required
(See
Section
9)
it
may
be
obtained
from
Worcester
Heat
Systems
Ltd. ONE
EXTENSION
FLUE
KIT ONLY
MAY
BE
USED
PER
APPLIANCE. Part No. ZAGAS066
Table 4
AVAILABLE PUMP HEADS
HEATING OUTPUT HEAD MIN. FLOW RATE OPTIMUM
kW Btu/h METRES
FEET
LITRES/MIN.
GALUMIN.
TEMPERATURE
RISE
8.8 (30,000)
5.1
16.6
8.41
1.89
11
(37,500) 4.7 15.5
10.51
2.36
13
(44,350) 4.3
14.1
12.42 2.79
15°C
between
15
(51,200) 3.8 12.6 14.33 3.22
heating
flow
and
return
17
(58,000) 3.3 10.9 16.24 3.65
19
(64,800) 2.2 7.2 18.15 4.08
23.4 (80,000) 1.5 5.0 22.35 5.02
3