Yunca Heating MONTE Manuale utente

Monte Multi & Monte Euro Multi Installation - AUG_2014.doc www.yunca.co.nz Page 1 of 4
A division of Terry Young Ltd, New Zealand
INSTALLATION INSTRUCTIONS for
MONTE MULTI-FUEL & MONTE EURO MULTI-FUEL
FREESTANDING BURNER
REFER TO APPLIED RESEARCH TEST REPORT 12/2514 APRIL 2012
TESTED in compliance with the requirements of AS/NZS 2918:2001
The Yunca Monte Multi-Fuel and Monte Euro Multi-Fuel are NOT clean-air approved.
A. Yunca recommends that competent trades persons carry out all installations (e.g. NZHHA
Registered Installer), to obtain maximum performance and safe, efficient heating.
B. A permit is required and we suggest you check with local building inspectors as by-laws
do vary from area to area.
Also notify your Insurance Company that a solid fuel heater has been installed.
C. Ash Floor Protector –
1. Must extend a minimum of 300mm in front of the door aperture.
2. Must extend at least 125mm from each side of the heater.
3. Ash Floor Protector must be constructed of non-combustible materials.
D. Seismic restraint –Heater must be restrained from seismic movement as required by
AS/NZS 2918:2001. 10mm diameter bolting holes in the rear corners allow restraint.
E. Manufacturers recommended tested minimum clearances from combustible walls:
Tested to NZS by APPLIED RESEARCH SERVICES
Clearance
Rear Clearance (with YUNCA flue guard fitted)
150mm
Side Clearance (with YUNCA flue guard fitted)
400mm
Corner Clearance (with YUNCA flue guard fitted)
200mm
F. YUNCA Flue Kit (Complies to AS/NZS 2918:2001 Appendix F): FIG A, B & E
1. 4.2m x 150mm stainless steel flue. 4. 1 x insulation boundary shield.
2. 2.4m x 250mm galvanised liner. 5. 2 x spider brackets.
3. 1 x ceiling tile. 6. 1 x weather cap & cowl.
7. 4 x support angles
Please Note: All joints must be sealed with flue sealing compound. Use stainless steel
screws or rivets to join the flue pipe (three equally spaced places at each joint). The first
length of flue must be fixed to the flue spigot with at least one stainless steel screw or rivet.
The required minimum flue termination height is 4.6 m above the floor protector.
G. MULTI-FUEL & EURO MULTI-FUEL Flue Mounted Shield (Flue Guard) Kit: FIG A
Complies (with heater) to AS/NZS 2918:2001
1 x 1200mm length lined Back Guard.
1 x 1200mm length Perforated Front Guard.
1 x 1200mm length Tertiary Back Guard with spacers.
1 x top front deflector shield (half round shaped, angled when installed).
Please Note: The minimum Flue Guard Height is 1200mm.

Monte Multi & Monte Euro Multi Installation - AUG_2014.doc www.yunca.co.nz Page 2 of 4
MONTE MULTI-FUEL & MONTE EURO MULTI-FUEL –TYPICAL FLUE INSTALLATION
(drawings on the following pages not drawn to scale)
FIG A MONTE MULTI-FUEL & MONTE EURO MULTI-FUEL Flue Mounted Shield
(Flue Guard) Kit Installation
Complies (with heater) to AS/NZS 2918:2001
CEILING PLATE
25mm min. BETWEEN LINER & ANY TIMBER
ENLARGEMENT OF CEILING ASSEMBLY
300
300mm Sq. TIMBER FRAME
TIMBER RAILS
SUPPORT ANGLES
LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM
INSULATION BOUNDARY SHIELD
CUT CEILING MATERIAL
BACK 25mm CLEAR
OF BOUNDARY SHEILD.
CEILING
25
300
CONDITIONS FOR FLUES (Refer Fig. E)
1. The FLUE shall extend to:
Not less than 600mm above the highest
point on the roof if within 3.0m of that point,
or
Not less than 1000mm above the
intersection point with the roof and not lower
than any point of the roof within 3.0m.
In any case the length of the flue shall not be
less than 4.6m from the ash floor protector.
In some situations the Local Council may
vary the above requirements.
2. The flue system must be tested and comply
with AS/NZS2918:2001, Appendix F.
3. The insulation boundary shield shall be
capable of preventing accidental migration of
loose-fill or any combustible material by any
action of wind or by persons moving in the
ceiling space.
These instructions spare parts information,
operation and maintenance guides may be
downloaded from www.yunca.co.nz
FIG B
FIG B.
Note! All Dimensions are in millimetres

Monte Multi & Monte Euro Multi Installation - AUG_2014.doc www.yunca.co.nz Page 3 of 4
FIG. C: HEATER DIMENSIONS & WATER BOOSTER POSITION –Monte MF & Euro MF
(not to scale)
FIG.D: HEATER POSITION. (Not to scale)
Above: Non combustible wall clearances. Brick lining.
From the floor to within 25mm of ceiling. Leave air vents at
the bottom to allow airflow in the cavity. If Yunca flue
mounted shield is fitted, brickwork may be 1200mm high as
long as all vertical joints in top and bottom of brickwork are
left out to allow airflow when brickwork is capped.
FIG D: MINIMUM FIRE TO COMBUSTABLE WALL CLEARANCES –MONTE MF & Euro MF
(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres.
A
B
E
F
G
H
150
400
200
314
732
519
FIG D: MINIMUM FLOOR PROTECTION MEASUREMENTS
(WITH YUNCA FLUE MOUNTED SHIELD FITTED). Measurements in millimetres.
C
D
J
K
L
M
N
O
P
300
125
913
947
1367
1208
633
663
647
FOR ACCESS

Monte Multi & Monte Euro Multi Installation - AUG_2014.doc www.yunca.co.nz Page 4 of 4
FIG E: FLUE SYSTEM REQUIREMENTS (not to scale)
More than 30003000
or less
600 min.
3000
1000 min. if clear
within 3000 of
flue top
.
3000
Any nearby
structure
.
1000 min. if clear
within 3000 of
flue top
MINIMUM HEIGHT OF FLUE SYSTEM EXIT
NOTE : Dimensions are in millimetres
3000
or less
600 min.
More than 3000
3000
.
Increase from
1000 min. until
clear within
3000 of flue top
IMPORTANT INFORMATION
A. The appliance and flue system shall be installed in compliance with AS/NZS 2918:2001 and
the appropriate requirements of the relevant building code or codes.
B. Mixing of appliance or flue system components from different sources or modifying the
dimensional specification of components may result in hazardous conditions. Where such
action is considered, the manufacturer should be consulted in the first instance.
C. Cracked and broken components e.g. glass panels or fire bricks, may render the installation
unsafe.
IF A WATERBOOSTER IS FITTED:
A. Do not connect to an unvented hot water system
B. Install in accordance with AS 3500.4.1 or NZS 4603 and the appropriate requirements of the
relevant building codes.
Seismic Restraint
Secure the heater base to the hearth or sub-framing with Dynabolts or similar, through the holes
provided in the heater base.
Follow local Council’s Specifications.
The Yunca Monte Multi-Fuel and Monte Euro Multi-Fuel are NOT clean-air approved.