Overview of WIFIKIT Function
Zeus AppolloTM-WIFIKIT has been developed by Zeus Appollo Solar as an external
communication monitoring device, which integrates a Wi-Fi device for users and provides a
wireless monitoring function.
By connecting with inverters through an RS485 interface, the Kit can receive information
from inverters and realize cascade connection of inverters. It can not only provide a wireless
function, but also can be used via a cable to transfer inverter data to the web server
Users can monitor the runtime status of the device by checking the 4 LEDs on the panel, that
indicate Power, RS485, Link and Status respectively.

1
Catalogue
1 Communication cable connection ........................................................................................................2
1.1 Inverter with RJ45 connector.........................................................................................................2
1.1.1 Cable connector preparation ....................................................................................................2
1.1.2 Installation.................................................................................................................................5
1.2 Inverter without RJ45 connector....................................................................................................6
1.2.1 Disassembly..............................................................................................................................6
1.2.2 Installation.................................................................................................................................7
2 Zeus AppolloTM –WIFIKIT User Manual ............................................................................................... 9
2.1 Unpack...........................................................................................................................................9
2.2 The installation of data collector.................................................................................................... 9
2.2.1 Wall-mounted installation.......................................................................................................... 9
2.2.2 Horizontal data collector installation.......................................................................................10
2.3 Connection between data collector and inverter.........................................................................10
2.3.1 The instructions of data collector interface and connection line interface .............................10
2.3.2 Steps of connection ................................................................................................................11
2.4 Wi-Fi settings...............................................................................................................................12
2.4.1 Wireless Network....................................................................................................................12
2.4.2 Wired network......................................................................................................................... 21
2.5 Debug .......................................................................................................................................... 22
2.6 Register on monitoring website...................................................................................................24
2.6.1 Click Register button to go to registering interface for new account................................... 25
2.6.2 Fill in user’s information as required ....................................................................................26
2.7 Login the PV monitoring system to manage the power station................................................... 29
2.8 IPhone & iPad application ...........................................................................................................34
3 Contact................................................................................................................................................36

2
1 Communication cable connection
1.1 Three Phase Inverter
For Zeus AppolloTM 3-phase inverters Z10I-13KDT/17KDT/20KDT, which have an integrated
RS485 interface, the cable connection for the inverter is as follows.
1.1.1 Cable connector preparation
In order to satisfy an IP65 level, the communication cable needs to be specifically prepared.
A. Find the LTW waterproof cable connector in the package of inverter. There are
two sets inside of each package. Then prepare the appropriate length of the
RS485 communication cable which has no plug.
Picture 1.1.1

3
B. Place the SEAL inside of the HOUSING as Picture 1.1.2.
Picture 1.1.2
C. Thread the communication cable through the Sealing Nut, SCREW, SEAL,
HOUSING and don’t tighten the Sealing Nut.
Picture 1.1.3
D. Put the cable terminal into the plug in the correct order as Picture 1.1.4
Picture 1.1.4
SEAL
HOUSING
Line sequence of T568B
1. orange with white
2. orange
3. green with white
4. blue
5. blue with white
6. green
7. brown with white
8. brown

4
E. Clamp the plug with a cable clamp as in Picture 1.1.5
Picture 1.1.5
F. Insert the plug into the HOUSING with the GASKET as in Picture 1.1.6.
Picture 1.1.6
G. Tighten the Sealing Nut applying a torque of 3Nm, Picture 1.1.7 shows an
assembled connector.
Picture 1.1.7
H. In order to connect the cable to other inverters, please prepare the other
terminal by the same method.

5
1.1.2 Installation
After the connector is assembled, the next step is to connect the cable to the inverter. The
following steps show the installation method.
First open the cap of the RS485, there is an RJ45 connector inside.
Picture 1.1.8
Then put the plug into the RJ45 connector, tighten the screw to the inverter applying a torque
of 3Nm.
Picture 1.1.9
Complete the other connection by the same method.

6
1.2 Single Phase Inverters
For Zeus AppolloTM inverters Z10I-1K/1K5/2K/2K5/3K, Z10I-3KD/4KD/5KD, which have an
integrated RS485 interface, the cable connection for the inverter is as follows.
1.2.1 Disassembly
Picture 1.2.1
Unscrew the four screws on the interface panel with the screwdriver as shown in Picture
1.2.1 Leaving the screws in position.
Picture 1.2.2

7
Picture 1.2.3
Unscrew the two-holed water-proofing connector from the interface panel as shown in
Picture 1.2.2, 1.2.3.
1.2.2 Installation
Extract the net cable and the water-proofing connector from the package and follow the
Pictures below:
A. Put the net cable in from the gap
B. Put the net cable one after another into the neck of the interface panel
Picture 1.2.4
C. Finish the installation, as Picture 1.2.5:

8
Picture 1.2.5